Honeywell D1-528 Direct Thermostat Installation Guide
INNCOM DIRECT D1-528 THERMOSTAT INSTALLATION GUIDE
8. If you want to change the value, use the UP/DOWN
arrow buttons to select the desired value, then press
DISPLAY.
If the target received the command, it should adopt
the defined settings and address and RESET. On
startup, the target device should broadcast a
“0x00031” Sound Buzzer VFI. If the D1-528 receives
this it will beep as feedback that the bind was suc-
cessful.
The D1-528 will change the value, revert back to
displaying SET P X and OUTSIDE will begin to blink
on the display indicating a change has been made to
a Registry and the change needs to be committed.
If configuring a CBL32 Evora or Modeva, CBL8 S217.RF
or L208.RF, or any CBL8 S5 bus device, these get
configured with a “Forward Bind” where you initiate the
bind/configuration from the D1-528:
Address Parameter (Adr)
Use the Adr parameter to set the address of a target
device while at the same time Bind the target device’s
radio (if applicable) to the D1-528’s current RF Room ID,
PAN ID and RF Channel.
1. Prepare the target device:
• For any CBL32 device that uses a forward bind,
place the target device into “Ready to Teach”
mode by pressing a button on the target 2
times quickly (Tap-Tap), then press the button
for 4-7 seconds. This depends on the target
device however and its software revision. Refer
to applicable commissioning documentation if
in doubt. The button LED’s on the device
should begin to blink once/minute.
1. Press and hold
mode.
2. Press the UP/DOWN arrow button and select Adr
for 4 seconds to enter into service
parameter.
• For an CBL8 S217.RF, L208.RF or other CBL8
RF device, press a button on the device 3 times
(tap-tap-tap) to put the device into “Ready to
Teach mode. There will be no visible feedback.
ºF ºC
• For S5-bus connected , non-RF CBL8 devices,
they do not need to be placed into a “Ready to
Teach” mode.
2. Press DISPLAY button on the D1-528. The D1-528
will display bnd will send an RF Bind/Teach and a
0x0004B P5 Address Teach command.
If the target device received the RF Bind/ Address
Teach command:
A
DISPLAY
3. Press DISPLAY button to view the value.
V 1 will appear by default.
4. Press the UP/DOWN and change value to the
Address the target should adopt. For example you
want to set the address in another room device to 17.
• For any CBL32 device, the button LEDs will
begin to flash 2 times/second.
If configuring an address in a CBL32 PC502.4G,CBL32
D454, CBL32 X47, RF Saflok lock or similar device that
does not have front facing buttons, and uses a Reverse
Bind, press the POWER button and bnd will appear
indicating the D1-528 is now waiting to see a reverse
bind request sent from the target device.
• For a CBL8 S217.RF, L208.RF or other CBL8
RF device or S5-bus connected, non-RF CBL8
devices the button LEDs will begin to blink
rapidly.
3. Accept the Bind/Teach on the target:
• For any CBL32 device, press a button on the
device 2 times quickly (Tap-Tap), then press
the button for 4-7 seconds to accept the Bind.
The CBL32 device should RESET and
These devices use a “Reverse Bind” where you initiate
configuration from the target device by pressing a
button on the target or use an “Enable” card (Saflok RF
Lock) to make the device send a 0x00110 bind request.
broadcast a “0x00031” Sound Buzzer VFI. If
the D1-528 receives this it will beep as
feedback that the bind was successful.
1. Press the Bind switch on the target device or for a
Saflok RF lock use the RF enable/bind card, to make
the target send a 0x00110 Bind Request.
• For a CBL8 S217.RF, L208.RF or other CBL8
RF device or S5-bus connected, non-RF CBL8
devices press any button on the device to
accept the bind/configuration. The device
should RESET, but will not provide any audible
feedback.
Upon seeing the Bind Request from the device, the
D1-528 will broadcast an RF Teach/Bind and P5
0x00112 Layer-X Bind command containing the
defined Address and RF parameters. Any device with
a radio will Directly process the RF Teach command.
Any S5-bus device connected to an existing RF device
will process the P5 0x00112 Layer-X Bind command
once it has been “media gateway’ed” from RF onto the
S5-bus.
31-00721-01
32
| General | Details |
|---|---|
| Name | Honeywell D1-528 Direct Thermostat Installation Guide |
| Make | Honeywell |
| Language | English |
| Filetype | PDF (Download) |
| File size | 1.63 MB |

Honeywell T6 Pro Programmable Thermostat User Manual

Honeywell FocusPRO P200 Programmable Thermostat User Guide

Honeywell RCHT8610WF Series Smart Thermostat Installation Guide

Honeywell T9 Smart Thermostat Installation Guide

Honeywell TH2320WF4011 FocusPRO Smart S200 Series Thermostat User Guide

Honeywell TL116A Thermostat Installation Guide

T10 Pro Smart Thermostat with Redlink Room Sensor

Honeywell TH6320WF2003 Lyric T6 Pro Wi-Fi Programmable Thermostat User Guide

Honeywell RTH9580 Wi-Fi Color Touchscreen Programmable Thermostat User Guide

Honeywell Smart Color Touchscreen Programmable Thermostat RTH9590 User Manual