AURATON Libra U Wireless Digital Room Thermostat User Manual
fluctuations.
For example, in the case of HI 2 hysteresis, when the temperature is set to 20°C, the boiler will be
switched on at 19.8°C, and switched off at 20.2°C. In the case of HI 4 hysteresis, when the
temperature is set to 20°C, the boiler will be switched on at 19.6°C, and switched off at 20.4°C.
The hysteresis change mode is signaled by a flashing HI. Turn the knob to the left or right to set the
desired hysteresis.
HI 2 – ±0,2 °C (preset),
HI 4 – ±0,4 °C,
HI P – PWM operating mode (see chapter “PWM operating mode”).
Confirm your choice by pressing the button. AURATON Libra will proceed to change the next
parameter.
Changes in the delay
The delay prevents too frequent activation of the actuator, e.g. due to temporary drafts (caused by
opening the window, etc.).