BATTERY PLACEMENT
RoomThermostatIndicator LED Descriptions
ENGLISH
If it blinks once
Room Thermostat sends a close signal to the
Receiver and the heating unit stops operating.
Room Thermostat sends an open signal to
the Receiver and the heating unit starts.
DIGITAL ROOM THERMOSTAT
If it blinks twice
generallife.com.tr
If it blinks three timesRoom Thermostat sends a pairing signal to
the Receiver.
RECEIVER
HT100S RF USER MANUAL
1-Manual Operation Button:
By disabling the Receiver, it enables you
1
GENERAL SPECIFICATIONS
DIGITAL ROOM THERMOSTAT
to use your boiler manually.
2-Pairing Button:
2
HT100S RF is a wireless room thermostat. The user can adjust the
room temperature with the required temperature and get more
comfortable and economic heating.
3
Allows to pair the Receiver with the
Room Thermostat.
3-Receiver LED Light
4-Receiver Power Cable Input
5-Boiler Connection Cable Input
As shown in the picture above, press the screwdriver forward from the
space shown, bend the tabs and separate the front cover. Insert 2 new
AAA alkaline batteries in the battery housing with the correct battery
direction. Replace both batteries at the same time. Then align the front
part of your Room Thermostat to the back and squeeze it towards the
back.
PreciseTemperatureMeasurement
WirelessConnection
TPIAlgorithm
ON/OFFControl
HT100S RF
USER MANUAL
HT100S RF AND EQUIPMENTS
HT100S RF
Room Thermostat
Alkaline
Battery
Holder
WARNING!
4
5
When the product is not used for a long period (more than 15 days),
remove the batteries. Otherwise, malfunctions that may occur would be
out of warranty.
RECEIVER LED DESCRIPTIONS
Pleasethrow yourdead batteriesinto thewastebin for batteries.
Steady Red
Receiver has power but Receiver and
Room Thermostat are not paired.
RECEIVER PLACEMENT
Blinking Green
Steady Green
Waiting for pairing signal from Room Thermostat.
Dowels and Screws
Receiver
The important things to note for the Receiver
placement is avoiding physical contact
between the Receiver and boiler, and
protecting it against materials such as
liquid,dust etc.
Receiver and Room Thermostat are paired.
Boiler is not operating.
3 Short Orange
Blinking
Operate the boiler signal has reached to the
Receiver.
Steady Orange
Boiler is operating.
TECHNICAL DATA
Room Thermostat
3 Short Green
Blinking
Shut the boiler down signal has reached to the
Receiver.
The devices should be placed in order to minimize the damage to the
received and transmitted signals by paying attention to the following
points;
Dimensions ( H / L / W )
Operating Current
85mm / 125mm / 24mm
Blinking Orange
Boiler is operating in manual mode.
3V DC (2 x AAA alkaline battery)
0.1oC
Temperature Measurement
Accuracy
The devicesshould not be mounted on metalsurfaces.
The devices should not be installed close to electrical cables and
electronic equipment such ascomputers and televisionunits.
The devices should not be installed near large metal structures or
other building materials using fine metal meshes such as special
glass or specialconcrete.
Blinking Red
Receiver did not get a signal from the
Room Thermostat for 22 minutes or longer and
boiler has shut down.
Operating Temperature Range
Battery Life
(5oC) – (35oC)
1 Year (2 x AAA)
(-10oC) – (+50oC)
(-20oC) – (+60oC)
ROOM THERMOSTAT PLACEMENT
Operating Temperature
Storage Temperature
Room Thermostat needs to be placed in the room which is used most
frequently. For instance; living room or lounge. Placing the Room
Thermostat in a spot that have air circulation like entrance of a room or
side of window should be avoided. Also anywhere close to heating units
such as radiator, stove and spots which get direct sun lights would not
be suitable. Room Thermostat needs to be located above the floor
150cmheight. Fewtrialsmaybe made to find themost convenientspot.
Distance between the Room Thermostat and the Receiver should not
exceed20metersor 2 floors.
Receiver
Receivermust be installedatleast50cmawayfrom theboiler.
Dimensions
90mm / 90mm / 25mm
230V AC
RECEIVER SETUP
Operation Current
Relay NO Switching Current
First, shut down your boiler and your boiler's power source with all
electricalcurrent(fuse,socketetc.)
7A (240VAC – Resistive load)
10A (120VAC – Resistive load)
(-20oC) – (+60oC)
As shown in the connection diagram, connect one end of the boiler
connection cable to the COM and the other to the NO input.of the
Receiver.
Storage Temperature
min.20 cm
ROOM THERMOSTAT
Connect the other ends of the cable -which you connected to the
Receiver- to room thermostat connection terminal as shown in your
boiler's usermanual.
You must first connect the Receiver power cable to the Receiver and
then to thefuse to which theboiler is connected.
Indicator LED
After completing the cable connection process,firstly turn on your
fuse and then yourboiler.
Adjustment Knob
By pressing the Receiver's manual usage button for 2 seconds, you
should see the Orange Light blinking on the Receiver. In this way, after
making sure that the boiler is operating, press the same button again
for 2 seconds and seethattheOrangeLEDturns off.
Set up the Room Thermostat to pair the Receiver with the Room
Thermostat.
generallife.com.tr
1
2
3
| General | Details |
|---|---|
| Name | GENERAL LIFE HT100S RF Wireless Room Thermostat User Manual |
| Make | GENERAL LIFE |
| Language | English |
| Filetype | PDF (Download) |
| File size | 2.21 MB |

GENERAL LIFE HT330S RF Room Thermostat User Manual

GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual

GENERAL LIFE HT250 RF Digital Room Thermostat User Manual

GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual

GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual

GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual

GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual

GENERAL LIFE 270 Wireless Room Thermostat User Manual

GENERAL LIFE HT220S RF Digital Room Thermostat User Manual

GENERAL LIFE 270S RF Room Thermostat User Manual

GENERAL LIFE HT100S RF Wireless Room Thermostat User Manual Overview
Summary of Contents
- Page 1: Battery placement is important for the room thermostat. The room thermostat sends signals to the receiver to control the heating unit. If the thermostat blinks once, it indicates the heating unit stops operating. A blink twice indicates the heating unit starts operating. A blink three times sends a pairing signal to the receiver. The HT100S RF is a wireless room thermostat for comfortable and economic heating. Receiver placement should avoid physical contact with the boiler and protect against dust and liquids. The room thermostat should be placed in frequently used rooms, avoiding areas with direct sunlight or near heating units. The distance between the room thermostat and receiver should not exceed 20 meters. Receiver setup requires shutting down the boiler and connecting the receiver correctly to ensure proper operation.
- Page 2: Warranty conditions state that the warranty period starts from the invoice date and lasts for 5 years against manufacturing defects. The receiver wiring diagram indicates that the room thermostat sends a status signal to the receiver every 10 minutes. If the signal is not received for 22 minutes, the receiver stops the boiler operation for safety reasons. Devices are delivered in working condition, and on-site commissioning is subject to a service fee. Repairs covered by the warranty are conducted at the company factory, and transportation costs are the customer's responsibility. Maintenance of devices is also done by the company, with travel fares covered by the customer. Malfunctions caused by customer misuse are not covered by the warranty. The TPI room thermostat has a learning process that restarts if its placement is changed or if it is de-energized. TPI technology ensures energy efficiency by predicting temperature changes and adjusting the heating unit accordingly. The warranty document must be retained by the customer, and a replacement will not be issued if lost.