Home > GENERAL LIFE > GENERAL LIFE HT100S RF Wireless Room Thermostat User Manual

GENERAL LIFE HT100S RF Wireless Room Thermostat User Manual

BATTERY PLACEMENT  
RoomThermostatIndicator LED Descriptions  
ENGLISH  
If it blinks once  
Room Thermostat sends a close signal to the  
Receiver and the heating unit stops operating.  
Room Thermostat sends an open signal to  
the Receiver and the heating unit starts.  
DIGITAL ROOM THERMOSTAT  
If it blinks twice  
generallife.com.tr  
If it blinks three timesRoom Thermostat sends a pairing signal to  
the Receiver.  
RECEIVER  
HT100S RF USER MANUAL  
1-Manual Operation Button:  
By disabling the Receiver, it enables you  
1
GENERAL SPECIFICATIONS  
DIGITAL ROOM THERMOSTAT  
to use your boiler manually.  
2-Pairing Button:  
2
HT100S RF is a wireless room thermostat. The user can adjust the  
room temperature with the required temperature and get more  
comfortable and economic heating.  
3
Allows to pair the Receiver with the  
Room Thermostat.  
3-Receiver LED Light  
4-Receiver Power Cable Input  
5-Boiler Connection Cable Input  
As shown in the picture above, press the screwdriver forward from the  
space shown, bend the tabs and separate the front cover. Insert 2 new  
AAA alkaline batteries in the battery housing with the correct battery  
direction. Replace both batteries at the same time. Then align the front  
part of your Room Thermostat to the back and squeeze it towards the  
back.  
PreciseTemperatureMeasurement  
WirelessConnection  
TPIAlgorithm  
ON/OFFControl  
HT100S RF  
USER MANUAL  
HT100S RF AND EQUIPMENTS  
HT100S RF  
Room Thermostat  
Alkaline  
Battery  
Holder  
WARNING!  
4
5
When the product is not used for a long period (more than 15 days),  
remove the batteries. Otherwise, malfunctions that may occur would be  
out of warranty.  
RECEIVER LED DESCRIPTIONS  
Pleasethrow yourdead batteriesinto thewastebin for batteries.  
Steady Red  
Receiver has power but Receiver and  
Room Thermostat are not paired.  
RECEIVER PLACEMENT  
Blinking Green  
Steady Green  
Waiting for pairing signal from Room Thermostat.  
Dowels and Screws  
Receiver  
The important things to note for the Receiver  
placement is avoiding physical contact  
between the Receiver and boiler, and  
protecting it against materials such as  
liquid,dust etc.  
Receiver and Room Thermostat are paired.  
Boiler is not operating.  
3 Short Orange  
Blinking  
Operate the boiler signal has reached to the  
Receiver.  
Steady Orange  
Boiler is operating.  
TECHNICAL DATA  
Room Thermostat  
3 Short Green  
Blinking  
Shut the boiler down signal has reached to the  
Receiver.  
The devices should be placed in order to minimize the damage to the  
received and transmitted signals by paying attention to the following  
points;  
Dimensions ( H / L / W )  
Operating Current  
85mm / 125mm / 24mm  
Blinking Orange  
Boiler is operating in manual mode.  
3V DC (2 x AAA alkaline battery)  
0.1oC  
Temperature Measurement  
Accuracy  
The devicesshould not be mounted on metalsurfaces.  
The devices should not be installed close to electrical cables and  
electronic equipment such ascomputers and televisionunits.  
The devices should not be installed near large metal structures or  
other building materials using fine metal meshes such as special  
glass or specialconcrete.  
Blinking Red  
Receiver did not get a signal from the  
Room Thermostat for 22 minutes or longer and  
boiler has shut down.  
Operating Temperature Range  
Battery Life  
(5oC) – (35oC)  
1 Year (2 x AAA)  
(-10oC) – (+50oC)  
(-20oC) – (+60oC)  
ROOM THERMOSTAT PLACEMENT  
Operating Temperature  
Storage Temperature  
Room Thermostat needs to be placed in the room which is used most  
frequently. For instance; living room or lounge. Placing the Room  
Thermostat in a spot that have air circulation like entrance of a room or  
side of window should be avoided. Also anywhere close to heating units  
such as radiator, stove and spots which get direct sun lights would not  
be suitable. Room Thermostat needs to be located above the floor  
150cmheight. Fewtrialsmaybe made to find themost convenientspot.  
Distance between the Room Thermostat and the Receiver should not  
exceed20metersor 2 floors.  
Receiver  
Receivermust be installedatleast50cmawayfrom theboiler.  
Dimensions  
90mm / 90mm / 25mm  
230V AC  
RECEIVER SETUP  
Operation Current  
Relay NO Switching Current  
First, shut down your boiler and your boiler's power source with all  
electricalcurrent(fuse,socketetc.)  
7A (240VAC – Resistive load)  
10A (120VAC – Resistive load)  
(-20oC) – (+60oC)  
As shown in the connection diagram, connect one end of the boiler  
connection cable to the COM and the other to the NO input.of the  
Receiver.  
Storage Temperature  
min.20 cm  
ROOM THERMOSTAT  
Connect the other ends of the cable -which you connected to the  
Receiver- to room thermostat connection terminal as shown in your  
boiler's usermanual.  
You must first connect the Receiver power cable to the Receiver and  
then to thefuse to which theboiler is connected.  
Indicator LED  
After completing the cable connection process,firstly turn on your  
fuse and then yourboiler.  
Adjustment Knob  
By pressing the Receiver's manual usage button for 2 seconds, you  
should see the Orange Light blinking on the Receiver. In this way, after  
making sure that the boiler is operating, press the same button again  
for 2 seconds and seethattheOrangeLEDturns off.  
Set up the Room Thermostat to pair the Receiver with the Room  
Thermostat.  
generallife.com.tr  
1
2
3
GeneralDetails
NameGENERAL LIFE HT100S RF Wireless Room Thermostat User Manual
MakeGENERAL LIFE
LanguageEnglish
FiletypePDF (Download)
File size2.21 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
GENERAL LIFE HT330S RF Room Thermostat User Manual
GENERAL LIFE HT330S RF Room Thermostat User Manual
GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual
GENERAL LIFE HT250 RF Digital Room Thermostat User Manual
GENERAL LIFE HT250 RF Digital Room Thermostat User Manual
GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual
GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual
GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual
GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual
GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual
GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual
GENERAL LIFE 270 Wireless Room Thermostat User Manual
GENERAL LIFE 270 Wireless Room Thermostat User Manual
GENERAL LIFE HT220S RF Digital Room Thermostat User Manual
GENERAL LIFE HT220S RF Digital Room Thermostat User Manual
GENERAL LIFE 270S RF Room Thermostat User Manual
GENERAL LIFE 270S RF Room Thermostat User Manual

GENERAL LIFE HT100S RF Wireless Room Thermostat User Manual
Get the free PDF manual for the GENERAL LIFE HT100S RF Wireless Room Thermostat User Manual and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

GENERAL LIFE HT100S RF Wireless Room Thermostat User Manual Overview

Summary of Contents

  • Page 1: Battery placement is important for the room thermostat. The room thermostat sends signals to the receiver to control the heating unit. If the thermostat blinks once, it indicates the heating unit stops operating. A blink twice indicates the heating unit starts operating. A blink three times sends a pairing signal to the receiver. The HT100S RF is a wireless room thermostat for comfortable and economic heating. Receiver placement should avoid physical contact with the boiler and protect against dust and liquids. The room thermostat should be placed in frequently used rooms, avoiding areas with direct sunlight or near heating units. The distance between the room thermostat and receiver should not exceed 20 meters. Receiver setup requires shutting down the boiler and connecting the receiver correctly to ensure proper operation.
  • Page 2: Warranty conditions state that the warranty period starts from the invoice date and lasts for 5 years against manufacturing defects. The receiver wiring diagram indicates that the room thermostat sends a status signal to the receiver every 10 minutes. If the signal is not received for 22 minutes, the receiver stops the boiler operation for safety reasons. Devices are delivered in working condition, and on-site commissioning is subject to a service fee. Repairs covered by the warranty are conducted at the company factory, and transportation costs are the customer's responsibility. Maintenance of devices is also done by the company, with travel fares covered by the customer. Malfunctions caused by customer misuse are not covered by the warranty. The TPI room thermostat has a learning process that restarts if its placement is changed or if it is de-energized. TPI technology ensures energy efficiency by predicting temperature changes and adjusting the heating unit accordingly. The warranty document must be retained by the customer, and a replacement will not be issued if lost.