ROOM THERMOSTAT PLACEMENT
WIRING DIAGRAM FOR ACTUATOR
ENGLISH
Place your Room Thermostat in a room you use frequently in your
living space. For example; like the hall or living room of your home.
Avoid installing the Room Thermostat in places where there is a lot of
air circulation, such as at the doorway or by the window. Also, do not
place it close to heating units (heater core, fireplace, etc.) and in direct
sunlight. We recommend that the room thermostat is placed at a
height of 150cmfrom thefloor.
N
L
L1
N1
UNDERFLOOR HEATING THERMOSTAT
generallife.com.tr
FH103S USER MANUAL
min. 20 cm
GENERAL SPECIFICATIONS
UNDERFLOOR HEATING THERMOSTAT
FH103S is a floor heating room thermostat. User provides more
comfortable and affordable heating by setting needed room
temperature.
SensitiveTemperatureMeasurement
Wired Connection
ACTUATOR
ON/ OFFControl
ROOM THERMOSTAT WORKING PRINCIPLE
FH103S
USER MANUAL
As soon as you energize your Room Thermostat, it will start working.
Your Room Thermostat measures the temperature of the
environment it is in every 5 seconds. If the ambient temperature rises
0.5 degrees above the temperature you set, your Room Thermostat
turns off the heating unit, and if it falls below 0.5 degrees, it turns on
theheating unit.
FH103S AND EQUIPMENTS
230V AC
FH103S Room Thermostat
Dowels and
Screws
WIRING DIAGRAM FOR WIRING CENTER
If the floor sensor measures temperature above 28°C, it turns off the
heating unit. The floor sensor operating sensitivityis ±1°C.*
Thus, it is ensured that the ambient temperature remains within a
certain range.
N
L
L1
N1
*Externalfloor sensor is only activewhen itis connected.
TECHNICAL DATA
Note: If a floor sensor is installed with Room Thermostat, only
GENERAL Life floor sensor should be installed. Otherwise, the
product willbe out of warranty.
Dimensions ( H / L / W )
Operating Current
Relay NO Switching Current
85.7mm / 85.7mm / 33.5mm
230V AC
7A (240VAC – Resistive load)
10A (120VAC – Resistive load)
0.1oC
ROOM THERMOSTAT WIRING DIAGRAM
Temperature Measurement
Accuracy
0.5oC
1
2
3
4
Operating Temperature Range
Operating Temperature
Storage Temperature
(5oC) – (30oC)
(-10oC) – (+50oC)
(-20oC) – (+60oC)
WIRING
CENTER
ROOM THERMOSTAT
230V AC
Indicator LED
Set Button
WARNING!
Operations related to the control panel, heating unit or electrical
installation must be carried out by persons with professional
qualifications.
5
N
L
NTC
L1
N1
WARNING!
6
RoomThermostatIndicator LED Descriptions
LED light is on
LED light is off
Heating unit is working
The assembly of product
Heating unit is not working
should be done according to
the image above.
For electrical connection,
please see diagram 5.
Should not be used in case
the usage of a wiring center.
generallife.com.tr
1
2
3
| General | Details |
|---|---|
| Name | GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual |
| Make | GENERAL LIFE |
| Language | English |
| Filetype | PDF (Download) |
| File size | 1.95 MB |

GENERAL LIFE HT330S RF Room Thermostat User Manual

GENERAL LIFE HT250 RF Digital Room Thermostat User Manual

GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual

GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual

GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual

GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual

GENERAL LIFE HT220S RF Digital Room Thermostat User Manual

GENERAL LIFE 270S RF Room Thermostat User Manual

GENERAL LIFE 270 Wireless Room Thermostat User Manual

GENERAL LIFE HT25 RF Wireless Room Thermostat User Manual