Ultra-large colorful screen capacitive touch LCD smart thermostat
√The device can obtain local weather condition and outdoor
temperature (optional)
√Customized exclusive temperature plan - up to 6 events allowed
to set per day
Sail-shape curved design - fashion, elegant and enduring
UItra-large screen -better user interaction experience
√
√
√
485 modbus and room card linkage - customized equipment (optional)
Parameter
Supply voltage
AC100~240V; 50/60Hz
1W Max (Wi-Fi 3W Max)
5~95℃(41~99℉)
20~90℃(68~99℉)
0.5~10℃(1~10℉), Factory setting ±1℃
-5~50℃(23~99℉)
IP20
Power consumption
Temp. setting range
Floor limited range
Temp. Dif.
Ambient temperature
Protection level
Shell material
Anti-Flammable PC
Version:TR9B 1.6(12/2023)
Product Overview
This series of thermostat has Floor Heating, Fan Coil, and Integrated version, meeting the
requirements under different scenarios.
User Operation
Power on/off : Press “ ” shortly to turn on/off the thermostat.
Auto-mode :
Press “ ” for 3 seconds to edit auto-mode settings.(Floor Heating/Integrated)
Press “ ” for 3 seconds to edit timer task. (Fan Coil/Integrated)
Timer task:
Version
System mode
Model
EP
Application
Time setting:
Press “ ” for 3 seconds to set time.(Floor Heating)
Built-in & floor sensor, floor limit sensor +
Weekly programming
Press “ ” twice for 3 seconds to set time.(Automatic time synch for Wi-Fi version)
Press “ ” or “ ” shortly to change setting temperature by 0.5°C.
Floor
heating
Heating
Temp setting:
Child-lock:
ANC/NO dual-output + Weekly programming
WP
ANC/NO dual-output + Weekly programming+
Potential-free output
Press “ ” + “ ” for 3 seconds to activate child-lock.
Press “ ” shortly to switch cooling/heating/ventilation.(Fan Coil)
Press “ ” shortly to switch cooling/heating/ventilation/floor heating/floor
heating + heating.(Integrated)
WPB
System mode:
Timer task + 2-pipe system
AC2
Heating /Cooling /
Ventilation
Fan Coil
AC2-485 Timer task + 2-pipe system + 485Modbus (optional)
Press “ ” shortly to switch manual/auto mode.(Floor heating)
Press “ ” shortly to switch manual/auto mode.(Integrated, floor heating)
Press “ ” shortly to adjust fan speed.(Fan Cail/Integrated)
Press“ ”shortly to set to ECO mode 18°C(64°F). (Floor heating)
Temp control mode:
Timer task + 4-pipe system + 485Modbus (optional)
AC4
Heating / Cooling /
Integrated Ventilation/Floor heating /
Floor heating + Heating
Floor heating & fan coil, weekly programming +
Potential-free output + Timer task +
485Modbus (optional) + Door card (optional)
Fan speed setting:
ECO mode:
AWY
Advanced Setting (Usually for Professional Technicians)
Under power-off, press “ ” for 3 seconds to enter advanced setting mode, then re-press
Display Symbols
“
” to switch to next mode. Press “ ” to save and exit advanced setting mode.
Floor
Heating
Integrated
FanCoil
Child-lock
Frost Protection
Wi-Fi(optional)
Timer Task
Default
Value
Meaning
Code
“
”or“
”
Time Display
AC2-
AWY
AC4 AC2 EP WP WPB
485
Indoor humidity(optional)
Postal address(optional) Adjustment range 0x00~0xFA
00
01
02
√
√
√
√ √
√ √ √
00
×
Wake up; Event 1
Leave (am); Event 2
Return (am); Event 3
Leave (pm); Event 4
Return (pm); Event 5
Sleep; Event 6
Weather forecast
(optional)
%
RH
Temp. calibration
Temp. Dif.
-9.9~9.9℃(-9~9℉)
√ √ √ √ √ √
-3℃
±1℃
Fan-Coil Cooling Mode
Fan-Coil Ventilation Mode
Room Temp.
Fan-Coil Heating Mode
Floor Heating Mode
Room Temp.
0.5~10℃(1~10℉)
√
√
√
√ √ √
√ √ √
√ √ √
√ √
√ √
√ √
Temp. upper limit
Temp. lower limit
03
04
5~95℃(41~99℉)
√
√
50℃
5℃
Set to
5~47℃(41~99℉)
Setting temp.
ON: frost protection on
OFF: frost protection off
Frost protection
Temperature unit
05
06
OFF √
√
√
√ √ √
√ √ √
√ √
√ √
Floor Temp.
Floor Heating on
Fan-Coil Heating on
Cooling on
Auto
ECO Mode
Manual Mode
Auto Mode
℃/℉
℃
√
IN:Controlledbybuilt-insensor
OUT:Limitedbyfloorsensor
ALL:Controlledbybuilt-insensorand
limitedbyfloorsensor
Temporary Mode
Fan
Week Display
Sensor selection
07
IN
√
×
√ √ √
√ √ √
× ×
× ×
Power
on/off
ECO/FanSpeed
Mode
Up
Down
Floor limited Value
08
09
20~90℃(68~99℉)
√
×
×
35℃
12345: 5/2 week mode
123456: 6/1 week mode
1234567: 7/0 week mode
Weeklyprogramming
setting
12345 √
× × √ √ √
Week Display
Wi-Fi
Frost Protection
00: Fan speed controllable
01: Fan speed uncontrollable
Timer Task
Fan control settings
Delaytimeofoutputs
10
11
00
√
√
√ √ √ × × ×
× × × √ √ √
Child-lock
Time Display
Room Temp.
Floor Heating Mode
0~5min
0
Fan-Coil Heating Mode
00: Child-lock inactivate when screen off;
lock all when child-lock activate
01: Child-lock activate when screen off;
lock all when child-lock activate
02: Child-lock activate when screen off;
lock all except Fan Speed, Up and
Down when child-lock activate
03: Child-lock activate when screen off;
lock all except Power on/off when
child-lock activate
ECO Mode
Fan-Coil Cooling Mode
Fan Speed Display
Cooling on
Room Temp.
Floor Temp.
Heating on
Fan-Coil Ventilation Mode
Manual Mode
Wake up; Event 1
Leave (am); Event 2
Return (am); Event 3
Leave (pm); Event 4
Return (pm); Event 5
Sleep; Event 6
Child-lock
12
00
√
√
√ √ √
√ √
Auto Mode
Temporary Mode
Power
on/off
00: Power OFF
Mode
ECO/FanSpeed
Up
Down
01: Power ON
Boot Status
13
14
02
00
√
√
√ √ √ √ √ √
√ × × × × ×
02:The last status before power loss
00:turnoffroomcardfunction
01:settoECOtemp. afterpullingroom
cardout
02:staypower-offafterpullingroom
cardout
Temperature Control Mode(Floor Heating/Integrated)
Manual Mode
Thermostat works based on manually-set temperature, disconnecting from auto mode.
Room card status
Room card heating
ECO temp.
Room card cooling
ECO temp.
Auto Mode
Weekly-circled programme, up to 6 heating events can be set per day. Heating events,
workdays and temperature can be separately customized based on personal routines.
15
16
17
10~21℃(50-69℉)
√
√
√
√ × × × × ×
√ × × × × ×
√ √ √ × × ×
18℃
26℃
00
22~32℃(72-89℉)
00: Cooling and heating
01: Cooling only
Fancoilmodesetting
Temporary Mode
Thermostat works based on manually-set temperature temporarily and then shifts
back to auto mode till next event.
Weeklyprogramming 00: turn on
forIntegrated
Reset
18
19
01
/
√
√
×
√
× × ×
√ √ √
× ×
√ √
01: turn off
Press “ ”for 3 seconds to reset
| General | Details |
|---|---|
| Name | SHANGHAI TR9B Ultra Large Colorful Screen Capacitive Touch LCD Smart Thermostat User Guide |
| Make | SHANGHAI |
| Language | English |
| Filetype | PDF (Download) |
| File size | 1.96 MB |

Shanghai TR9B Ultra Manual: Questions and Answers
Shanghai TR9B Ultra specifications
| Power supply | AC100~240V; 50/60Hz |
| Setpoint range | 5~95℃ / 41~99℉ |
| Operating temperature | -5~50℃ / 23~99℉ |
| IP rating | IP20 |
| Power consumption | 1W Max (Wi-Fi 3W Max) |
What is the difference between manual mode and auto mode on a Shanghai TR9B Ultra?
Manual mode holds a fixed temperature you set. Auto mode runs weekly programs with up to 6 heating events per day based on your schedule. User Guide, p. 1
Can I lock the buttons on a Shanghai TR9B Ultra to prevent accidental changes?
Yes. Press the child-lock button and the down button together for 3 seconds to activate child-lock. Lock behavior depends on the child-lock mode setting (code 12). User Guide, p. 1
Shanghai TR9B Ultra compared with other floor heating thermostats
| Specification | Shanghai TR9B Ultra | Heatit 54 304 DIN | Heatit Z-TRM3 | Namron 4512737 |
|---|---|---|---|---|
| Power supply | AC100~240V; 50/60Hz | 230VAC 50Hz | 230VAC 50/60Hz | 220-240V~50/60Hz |
| Setpoint range | 5~95℃ / 41~99℉ | 2°C to 40°C | 5°C to 40°C | 0°C to 40°C |
| Operating temperature | -5~50℃ / 23~99℉ | 5°C to 40°C | 2°C to 40°C (during operation) | 0°C to 40°C (during operation) |
| IP rating | IP20 | IP21 | IP 21 | IP21 |
| Power consumption | 1W Max (Wi-Fi 3W Max) | <2W | <2.0W | <2W |