SHANGHAI TR9B Ultra Large Colorful Screen Capacitive Touch LCD Smart Thermostat User Guide

Ultra-large colorful screen capacitive touch LCD smart thermostat  
√The device can obtain local weather condition and outdoor  
temperature (optional)  
√Customized exclusive temperature plan - up to 6 events allowed  
to set per day  
Sail-shape curved design - fashion, elegant and enduring  
UItra-large screen -better user interaction experience  
√
√
√
485 modbus and room card linkage - customized equipment (optional)  
Parameter  
Supply voltage  
AC100~240V; 50/60Hz  
1W Max (Wi-Fi 3W Max)  
5~95℃(41~99℉)  
20~90℃(68~99℉)  
0.5~10℃(1~10℉), Factory setting ±1℃  
-5~50℃(23~99℉)  
IP20  
Power consumption  
Temp. setting range  
Floor limited range  
Temp. Dif.  
Ambient temperature  
Protection level  
Shell material  
Anti-Flammable PC  
Version:TR9B 1.6(12/2023)  
Product Overview  
This series of thermostat has Floor Heating, Fan Coil, and Integrated version, meeting the  
requirements under different scenarios.  
User Operation  
Power on/off : Press “ ” shortly to turn on/off the thermostat.  
Auto-mode :  
Press “ ” for 3 seconds to edit auto-mode settings.(Floor Heating/Integrated)  
Press “ ” for 3 seconds to edit timer task. (Fan Coil/Integrated)  
Timer task:  
Version  
System mode  
Model  
EP  
Application  
Time setting:  
Press “ ” for 3 seconds to set time.(Floor Heating)  
Built-in & floor sensor, floor limit sensor +  
Weekly programming  
Press “ ” twice for 3 seconds to set time.(Automatic time synch for Wi-Fi version)  
Press “ ” or “ ” shortly to change setting temperature by 0.5°C.  
Floor  
heating  
Heating  
Temp setting:  
Child-lock:  
ANC/NO dual-output + Weekly programming  
WP  
ANC/NO dual-output + Weekly programming+  
Potential-free output  
Press “ ” + “ ” for 3 seconds to activate child-lock.  
Press “ ” shortly to switch cooling/heating/ventilation.(Fan Coil)  
Press “ ” shortly to switch cooling/heating/ventilation/floor heating/floor  
heating + heating.(Integrated)  
WPB  
System mode:  
Timer task + 2-pipe system  
AC2  
Heating /Cooling /  
Ventilation  
Fan Coil  
AC2-485 Timer task + 2-pipe system + 485Modbus (optional)  
Press “ ” shortly to switch manual/auto mode.(Floor heating)  
Press “ ” shortly to switch manual/auto mode.(Integrated, floor heating)  
Press “ ” shortly to adjust fan speed.(Fan Cail/Integrated)  
Press“ ”shortly to set to ECO mode 18°C(64°F). (Floor heating)  
Temp control mode:  
Timer task + 4-pipe system + 485Modbus (optional)  
AC4  
Heating / Cooling /  
Integrated Ventilation/Floor heating /  
Floor heating + Heating  
Floor heating & fan coil, weekly programming +  
Potential-free output + Timer task +  
485Modbus (optional) + Door card (optional)  
Fan speed setting:  
ECO mode:  
AWY  
Advanced Setting (Usually for Professional Technicians)  
Under power-off, press “ ” for 3 seconds to enter advanced setting mode, then re-press  
Display Symbols  
“
” to switch to next mode. Press “ ” to save and exit advanced setting mode.  
Floor  
Heating  
Integrated  
FanCoil  
Child-lock  
Frost Protection  
Wi-Fi(optional)  
Timer Task  
Default  
Value  
Meaning  
Code  
“
”or“  
”
Time Display  
AC2-  
AWY  
AC4 AC2 EP WP WPB  
485  
Indoor humidity(optional)  
Postal address(optional) Adjustment range 0x00~0xFA  
00  
01  
02  
√
√
√
√ √  
√ √ √  
00  
×
Wake up; Event 1  
Leave (am); Event 2  
Return (am); Event 3  
Leave (pm); Event 4  
Return (pm); Event 5  
Sleep; Event 6  
Weather forecast  
(optional)  
%
RH  
Temp. calibration  
Temp. Dif.  
-9.9~9.9℃(-9~9℉)  
√ √ √ √ √ √  
-3℃  
±1℃  
Fan-Coil Cooling Mode  
Fan-Coil Ventilation Mode  
Room Temp.  
Fan-Coil Heating Mode  
Floor Heating Mode  
Room Temp.  
0.5~10℃(1~10℉)  
√
√
√
√ √ √  
√ √ √  
√ √ √  
√ √  
√ √  
√ √  
Temp. upper limit  
Temp. lower limit  
03  
04  
5~95℃(41~99℉)  
√
√
50℃  
5℃  
Set to  
5~47℃(41~99℉)  
Setting temp.  
ON: frost protection on  
OFF: frost protection off  
Frost protection  
Temperature unit  
05  
06  
OFF √  
√
√
√ √ √  
√ √ √  
√ √  
√ √  
Floor Temp.  
Floor Heating on  
Fan-Coil Heating on  
Cooling on  
Auto  
ECO Mode  
Manual Mode  
Auto Mode  
℃/℉  
℃
√
IN:Controlledbybuilt-insensor  
OUT:Limitedbyfloorsensor  
ALL:Controlledbybuilt-insensorand  
limitedbyfloorsensor  
Temporary Mode  
Fan  
Week Display  
Sensor selection  
07  
IN  
√
×
√ √ √  
√ √ √  
× ×  
× ×  
Power  
on/off  
ECO/FanSpeed  
Mode  
Up  
Down  
Floor limited Value  
08  
09  
20~90℃(68~99℉)  
√
×
×
35℃  
12345: 5/2 week mode  
123456: 6/1 week mode  
1234567: 7/0 week mode  
Weeklyprogramming  
setting  
12345 √  
× × √ √ √  
Week Display  
Wi-Fi  
Frost Protection  
00: Fan speed controllable  
01: Fan speed uncontrollable  
Timer Task  
Fan control settings  
Delaytimeofoutputs  
10  
11  
00  
√
√
√ √ √ × × ×  
× × × √ √ √  
Child-lock  
Time Display  
Room Temp.  
Floor Heating Mode  
0~5min  
0
Fan-Coil Heating Mode  
00: Child-lock inactivate when screen off;  
lock all when child-lock activate  
01: Child-lock activate when screen off;  
lock all when child-lock activate  
02: Child-lock activate when screen off;  
lock all except Fan Speed, Up and  
Down when child-lock activate  
03: Child-lock activate when screen off;  
lock all except Power on/off when  
child-lock activate  
ECO Mode  
Fan-Coil Cooling Mode  
Fan Speed Display  
Cooling on  
Room Temp.  
Floor Temp.  
Heating on  
Fan-Coil Ventilation Mode  
Manual Mode  
Wake up; Event 1  
Leave (am); Event 2  
Return (am); Event 3  
Leave (pm); Event 4  
Return (pm); Event 5  
Sleep; Event 6  
Child-lock  
12  
00  
√
√
√ √ √  
√ √  
Auto Mode  
Temporary Mode  
Power  
on/off  
00: Power OFF  
Mode  
ECO/FanSpeed  
Up  
Down  
01: Power ON  
Boot Status  
13  
14  
02  
00  
√
√
√ √ √ √ √ √  
√ × × × × ×  
02:The last status before power loss  
00:turnoffroomcardfunction  
01:settoECOtemp. afterpullingroom  
cardout  
02:staypower-offafterpullingroom  
cardout  
Temperature Control Mode(Floor Heating/Integrated)  
Manual Mode  
Thermostat works based on manually-set temperature, disconnecting from auto mode.  
Room card status  
Room card heating  
ECO temp.  
Room card cooling  
ECO temp.  
Auto Mode  
Weekly-circled programme, up to 6 heating events can be set per day. Heating events,  
workdays and temperature can be separately customized based on personal routines.  
15  
16  
17  
10~21℃(50-69℉)  
√
√
√
√ × × × × ×  
√ × × × × ×  
√ √ √ × × ×  
18℃  
26℃  
00  
22~32℃(72-89℉)  
00: Cooling and heating  
01: Cooling only  
Fancoilmodesetting  
Temporary Mode  
Thermostat works based on manually-set temperature temporarily and then shifts  
back to auto mode till next event.  
Weeklyprogramming 00: turn on  
forIntegrated  
Reset  
18  
19  
01  
/
√
√
×
√
× × ×  
√ √ √  
× ×  
√ √  
01: turn off  
Press “ ”for 3 seconds to reset  
GeneralDetails
NameSHANGHAI TR9B Ultra Large Colorful Screen Capacitive Touch LCD Smart Thermostat User Guide
MakeSHANGHAI
LanguageEnglish
FiletypePDF (Download)
File size1.96 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...

SHANGHAI TR9B Ultra Large Colorful Screen Capacitive Touch LCD Smart Thermostat User Guide