Room Thermostat needs to be placed in the room which is used most
frequently.For instance; living room or lounge.Placing the Room
Thermostat in a spot that have air circulation like entrance of a room
or side of window should be avoided. Also anywhere close to heating
units such as radiator, stove and spots which get direct sun lights
would not be suitable. Room Thermostat needs to be located above
the floor 150 cm height. Few trials may be made to find the most
convenientspot.
HEATING UNIT
DIGITAL ROOM THERMOSTAT
generallife.com.tr
HT100S USER MANUAL
NO COM
GENERALSPECIFICATIONS
DIGITAL ROOM THERMOSTAT
min. 20 cm
HT100S is a wired room thermostat. The user can adjust the room
temperature with the required temperature and get more comfortable
and economic heating.
WARNING!
Operations inside the boiler or related to the electrical installation
must be carriedout bypersons withprofessional competence.
PreciseTemperatureMeasurement
Wired Connection
TPIAlgorithm
ON/OFFControl
HT100S
USER MANUAL
TPIROOMTHERMOSTATWORKINGLOGIC
HT100SANDEQUIPMENTS
Your Room Thermostat works with the TPI algorithm in the heating
option. Room Thermostats using TPI technology predict when the
temperature of your home will rise above or below the set
temperature and turn the heating unit on and off accordingly. This
ensures that your home stays at the temperature you set without
maximum deviationsup and down.
HT100S
Room Thermostat
Alkaline
Battery
Dowels and
Screws
What is TPI?
TPI technology is designed to ensure that you get the best possible
energy efficiency from yourheating system. It measures and applies the
best possible timings to deliver and maintain your home at the set
temperaturelevel.
TECHNICALDATA
BATTERY PLACEMENT
How does TPIwork?
Dimensions ( H / L / W )
Operating Current
85mm / 125mm / 24mm
3V DC (2 x AAA alkaline battery)
2A/30VDC (Resistive load)
0.5A/125VAC (Resistive load)
0.1oC
Thanks to the advanced artificial intelligence technology found in the
software, it adapts to the temperature change of the environment in
which it is located. By creating a general temperature map of your home,
it learns how long it takes to reach the desired room temperature and
how to maintain this temperature. In this way, it provides minimum
energy consumption by calculating how long your heating unit should
workfor.
Before starting, power off the device connected to the Room
Thermostatand makesurethattheenergy is cutoff.
Relay NO Switching Current
Temperature Measurement
Accuracy
Operating Temperature Range
Battery Life
(5oC) – (35oC)
1 Year (2 x AAA)
(-10oC) – (+50oC)
(-20oC) – (+60oC)
Whatisthedifference?
Operating Temperature
Storage Temperature
In non-TPI room thermostats, the heating unit works and stops
continuously until it exceeds the set temperature value. If the set
temperature drops below a certain amount, the heating unit will work
again. This creates greater temperature fluctuations and less energy
control. TPI Room Thermostats, on the other hand, provide higher
savings and comfort compared to On/Off room thermostats with the
advantagesithas.
ROOMTHERMOSTAT
As shown in the picture above, press the screwdriver forward from the
space shown, bend the tabs and separate the front cover. Insert 2 new
AAA alkaline batteries in the battery housing with the correct battery
direction. Replace both batteries at the same time. Then align the
front part of your Room Thermostat to the back and squeeze it
towards theback.
TPIROOMTHERMOSTATWORKINGGRAPHIC
TEMPERATURE (ºC)
Desired Temperature
TPI Room Thermostat
Indicator LED
30
Adjustment Knob
23
WARNING!
When the product is not used for a long period (more than 15 days),
remove the batteries. Otherwise, malfunctions that may occur would
be out of warranty.
RoomThermostatIndicatorLEDDescriptions
If it blinks once
If it blinks twice
The relay contact opens and the heating unit
Pleasethrow yourdead batteriesinto thewastebin for batteries.
stops working.
Time
5
The relay contact closes and the heating unit
starts.
generallife.com.tr
1
2
3
| General | Details |
|---|---|
| Name | GENERAL HT100S Digital Room Thermostat User Manual |
| Make | GENERAL |
| Language | English |
| Filetype | PDF (Download) |
| File size | 2.02 MB |

GENERAL ARUNA 300S Smart Room Thermostat User Manual

GENERAL HT250S Digital Room Thermostat User Manual

GENERAL FH260S Underfloor Heating Thermostat User Manual

GENERAL SOLARA 330S SMART Smart Room Thermostat User Manual

GENERAL HT250 Digital Room Thermostat User Manual

GENERAL SENNA 300 Digital Room Thermostat User Manual

GENERAL ARUNA 300S RF Digital Room Thermostat User Manual

GENERAL SENNA 300 Smart Room Thermostat User Manual

GENERAL MITRA 250S Digital Room Thermostat User Manual

GENERAL MITRA 220 RF Digital Room Thermostat User Manual

GENERAL HT100S Digital Room Thermostat User Manual Overview
Summary of Contents
- Page 1: Room thermostat needs to be placed in the room which is used most frequently. Placing the room thermostat in a spot with air circulation or close to heating units should be avoided. Room thermostat needs to be located above the floor at a height of 150 cm. HT100S is a wired room thermostat that allows users to adjust the room temperature for comfortable and economic heating. Operations inside the boiler or related to the electrical installation must be carried out by persons with professional competence. TPI technology ensures the best possible energy efficiency from your heating system by predicting temperature changes. The advanced artificial intelligence technology adapts to temperature changes and provides minimum energy consumption. Before starting, power off the device connected to the room thermostat and ensure that the energy is cut off. TPI room thermostats provide higher savings and comfort compared to On/Off room thermostats. When the product is not used for a long period, remove the batteries to avoid malfunctions.
- Page 2: What to know about TPI Room Thermostat Warranty conditions The warranty period starts from the invoice date and is warranted against manufacturing defects for 5 years. In case of malfunction of the devices within the warranty period, the time spent during the repair period is added to the warranty period. If the placement of the TPI Room Thermostats is changed, the learning process will restart and should be considered as 7 days. Devices and apparatus are delivered to the customer in working condition. The maintenance of devices and apparatus is done in our company. In case of malfunctioning of the devices, it is tested whether the malfunction is caused by a customer or manufacturer fault. The warranty document must be kept by the customer during the warranty period. Malfunctions resulting from the use of devices contrary to the matters stated in the User Manual are not covered by the warranty. Devices and their apparatus are out of warranty if they are beaten, broken, or scratched by the customer.