Home > GENERAL > GENERAL HT100S Digital Room Thermostat User Manual

GENERAL HT100S Digital Room Thermostat User Manual

ROOMTHERMOSTATPLACEMENT  
ROOMTHERMOSTATWIRINGDIAGRAM  
ENGLISH  
Room Thermostat needs to be placed in the room which is used most  
frequently.For instance; living room or lounge.Placing the Room  
Thermostat in a spot that have air circulation like entrance of a room  
or side of window should be avoided. Also anywhere close to heating  
units such as radiator, stove and spots which get direct sun lights  
would not be suitable. Room Thermostat needs to be located above  
the floor 150 cm height. Few trials may be made to find the most  
convenientspot.  
HEATING UNIT  
DIGITAL ROOM THERMOSTAT  
generallife.com.tr  
HT100S USER MANUAL  
NO COM  
GENERALSPECIFICATIONS  
DIGITAL ROOM THERMOSTAT  
min. 20 cm  
HT100S is a wired room thermostat. The user can adjust the room  
temperature with the required temperature and get more comfortable  
and economic heating.  
WARNING!  
Operations inside the boiler or related to the electrical installation  
must be carriedout bypersons withprofessional competence.  
PreciseTemperatureMeasurement  
Wired Connection  
TPIAlgorithm  
ON/OFFControl  
HT100S  
USER MANUAL  
TPIROOMTHERMOSTATWORKINGLOGIC  
HT100SANDEQUIPMENTS  
Your Room Thermostat works with the TPI algorithm in the heating  
option. Room Thermostats using TPI technology predict when the  
temperature of your home will rise above or below the set  
temperature and turn the heating unit on and off accordingly. This  
ensures that your home stays at the temperature you set without  
maximum deviationsup and down.  
HT100S  
Room Thermostat  
Alkaline  
Battery  
Dowels and  
Screws  
What is TPI?  
TPI technology is designed to ensure that you get the best possible  
energy efficiency from yourheating system. It measures and applies the  
best possible timings to deliver and maintain your home at the set  
temperaturelevel.  
TECHNICALDATA  
BATTERY PLACEMENT  
How does TPIwork?  
Dimensions ( H / L / W )  
Operating Current  
85mm / 125mm / 24mm  
3V DC (2 x AAA alkaline battery)  
2A/30VDC (Resistive load)  
0.5A/125VAC (Resistive load)  
0.1oC  
Thanks to the advanced artificial intelligence technology found in the  
software, it adapts to the temperature change of the environment in  
which it is located. By creating a general temperature map of your home,  
it learns how long it takes to reach the desired room temperature and  
how to maintain this temperature. In this way, it provides minimum  
energy consumption by calculating how long your heating unit should  
workfor.  
Before starting, power off the device connected to the Room  
Thermostatand makesurethattheenergy is cutoff.  
Relay NO Switching Current  
Temperature Measurement  
Accuracy  
Operating Temperature Range  
Battery Life  
(5oC) – (35oC)  
1 Year (2 x AAA)  
(-10oC) – (+50oC)  
(-20oC) – (+60oC)  
Whatisthedifference?  
Operating Temperature  
Storage Temperature  
In non-TPI room thermostats, the heating unit works and stops  
continuously until it exceeds the set temperature value. If the set  
temperature drops below a certain amount, the heating unit will work  
again. This creates greater temperature fluctuations and less energy  
control. TPI Room Thermostats, on the other hand, provide higher  
savings and comfort compared to On/Off room thermostats with the  
advantagesithas.  
ROOMTHERMOSTAT  
As shown in the picture above, press the screwdriver forward from the  
space shown, bend the tabs and separate the front cover. Insert 2 new  
AAA alkaline batteries in the battery housing with the correct battery  
direction. Replace both batteries at the same time. Then align the  
front part of your Room Thermostat to the back and squeeze it  
towards theback.  
TPIROOMTHERMOSTATWORKINGGRAPHIC  
TEMPERATURE (ºC)  
Desired Temperature  
TPI Room Thermostat  
Indicator LED  
30  
Adjustment Knob  
23  
WARNING!  
When the product is not used for a long period (more than 15 days),  
remove the batteries. Otherwise, malfunctions that may occur would  
be out of warranty.  
RoomThermostatIndicatorLEDDescriptions  
If it blinks once  
If it blinks twice  
The relay contact opens and the heating unit  
Pleasethrow yourdead batteriesinto thewastebin for batteries.  
stops working.  
Time  
5
The relay contact closes and the heating unit  
starts.  
generallife.com.tr  
1
2
3
GeneralDetails
NameGENERAL HT100S Digital Room Thermostat User Manual
MakeGENERAL
LanguageEnglish
FiletypePDF (Download)
File size2.02 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
GENERAL ARUNA 300S Smart Room Thermostat User Manual
GENERAL ARUNA 300S Smart Room Thermostat User Manual
GENERAL HT250S Digital Room Thermostat User Manual
GENERAL HT250S Digital Room Thermostat User Manual
GENERAL FH260S Underfloor Heating Thermostat User Manual
GENERAL FH260S Underfloor Heating Thermostat User Manual
GENERAL SOLARA 330S SMART Smart Room Thermostat User Manual
GENERAL SOLARA 330S SMART Smart Room Thermostat User Manual
GENERAL HT250 Digital Room Thermostat User Manual
GENERAL HT250 Digital Room Thermostat User Manual
GENERAL SENNA 300 Digital Room Thermostat User Manual
GENERAL SENNA 300 Digital Room Thermostat User Manual
GENERAL ARUNA 300S RF Digital Room Thermostat User Manual
GENERAL ARUNA 300S RF Digital Room Thermostat User Manual
GENERAL SENNA 300 Smart Room Thermostat User Manual
GENERAL SENNA 300 Smart Room Thermostat User Manual
GENERAL MITRA 250S Digital Room Thermostat User Manual
GENERAL MITRA 250S Digital Room Thermostat User Manual
GENERAL MITRA 220 RF Digital Room Thermostat User Manual
GENERAL MITRA 220 RF Digital Room Thermostat User Manual

GENERAL HT100S Digital Room Thermostat User Manual
Get the free PDF manual for the GENERAL HT100S Digital Room Thermostat User Manual and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

GENERAL HT100S Digital Room Thermostat User Manual Overview

Summary of Contents

  • Page 1: Room thermostat needs to be placed in the room which is used most frequently. Placing the room thermostat in a spot with air circulation or close to heating units should be avoided. Room thermostat needs to be located above the floor at a height of 150 cm. HT100S is a wired room thermostat that allows users to adjust the room temperature for comfortable and economic heating. Operations inside the boiler or related to the electrical installation must be carried out by persons with professional competence. TPI technology ensures the best possible energy efficiency from your heating system by predicting temperature changes. The advanced artificial intelligence technology adapts to temperature changes and provides minimum energy consumption. Before starting, power off the device connected to the room thermostat and ensure that the energy is cut off. TPI room thermostats provide higher savings and comfort compared to On/Off room thermostats. When the product is not used for a long period, remove the batteries to avoid malfunctions.
  • Page 2: What to know about TPI Room Thermostat Warranty conditions The warranty period starts from the invoice date and is warranted against manufacturing defects for 5 years. In case of malfunction of the devices within the warranty period, the time spent during the repair period is added to the warranty period. If the placement of the TPI Room Thermostats is changed, the learning process will restart and should be considered as 7 days. Devices and apparatus are delivered to the customer in working condition. The maintenance of devices and apparatus is done in our company. In case of malfunctioning of the devices, it is tested whether the malfunction is caused by a customer or manufacturer fault. The warranty document must be kept by the customer during the warranty period. Malfunctions resulting from the use of devices contrary to the matters stated in the User Manual are not covered by the warranty. Devices and their apparatus are out of warranty if they are beaten, broken, or scratched by the customer.