Home > GENERAL > GENERAL ARUNA 300S Smart Room Thermostat User Manual

GENERAL ARUNA 300S Smart Room Thermostat User Manual

ROOMTHERMOSTAT  
ButtonFunctions  
BATTERY PLACEMENT  
SMARTRECEIVERSETUP  
ENGLISH  
For smart receiver setup, download the Smart Life application from App Store or  
Google Play or scan the QR code below with your smartphone. In this way, you will  
be able to download the Smart Life mobile application from App Store or Google  
SMART ROOM THERMOSTAT  
Play to your smartphone. (You may be required to have  
a
QR code reader  
application depending on thebrand and model of yourphone, for this process.)  
generallife.com.tr  
1
4
2
3
5
6
ARUNA 300S SMART USER MANUAL  
1
2
3
4
5
6
On/Off Button  
Heating & Cooling Option  
Weekly Program Button  
Temperature Adjustment Button (To Decrease)  
Temperature Adjustment Button (To Increase)  
Mode Button  
WHATISA SMARTROOMTHERMOSTAT?  
A
Pressthe screwdriverforward fromthe space at the bottom of the room thermostat,  
bend the tabs and separate the front cover. Insert 2 new AAA alkaline batteries in  
the battery housing with the correct battery direction. Replace both batteries at the  
same time. Align the front part of your room thermostat with the corresponding slot  
on theback, and then push gently until thethermostatsnaps into place.  
smart room thermostat is  
a
device that allows you to control your heating  
equipment viaAPPwiththeinternetevenwhen youarenot athome.  
Complete the user registration process by opening the mobile application that  
youdownloaded.  
ProductDisplayLayout  
HOWDOESARUNA 300SSMARTWORK?  
Open theBluetooth fromyourmobile phone's settings.  
After you completed the user registration process, press the “+” button in the top-  
right corner of the main screen of the application, Press the receiver's Wi-Fi  
pairing button for 5 seconds.  
ARUNA 300S SMART is a smart wireless room thermostat. You can control it with  
the mobile application after you pair your room thermostat with the receiver, and  
completetheinstallationofthesmartreceiver.  
7
8
1
Low Battery Warning: When the “ ” icon appears on the screen, it means “low battery  
warning”. Itis recommended to replacethebatteries when this warning appears.  
Warning: When the product is not used for a long period (more than 15 days), remove  
the batteries. Otherwise, malfunctions that may occur would be out of warranty.  
Pleasethrowyourdead batteries into thewastebin forbatteries.  
2
The LEDon thereceiverwillstart to blink green.  
Setup will begin with Bluetooth in the application. When the device is found, press  
theAdd” button.  
9
3
WHATARETHEADVANTAGESOFARUNA300SSMART?  
10  
11  
You can control your home's temperature via its mobile application, no matter  
whereyouarein theworld.  
4
5
6
Uygulamada bluetooth ile kurulum başlayacaktır. Cihaz bulununca “Add”  
butonuna basınız.  
RECEIVERPLACEMENT  
You can easilycreatedaily and weeklyschedules viaitsmobile application.  
You can place the room thermostat anywhere in your home, thanks to its use with  
batteries.  
The important things to note for the Receiver placement are  
avoiding physical contact between the receiver and the  
heating/cooling unit, and protectingitagainst materialssuch  
asliquid, dust, etc.  
Press the “+” button near the W Modem device and press the “Next” button after  
making surethatyouenteredthecorrectWi-Fiinformation.  
Wait until the setup process is completed. When you saw the green approval  
symbol on theW Modem, presstheDone” button in thetop-right corner.  
1
2
3
4
5
6
7
8
9
Hour Indicator  
It ensures that your living space stays at the desired temperature at any time. In  
this way, you can saveup to 30% on your bills by preventingyour heating unit from  
working unnecessarily.  
Room Temperature  
Economy Mode  
Comfort Mode  
Holiday Mode  
Weekly Program Mode  
Day Indicator  
Battery Indicator  
Set Temperature  
Heating Indicator  
- If the Heating Indicator is blinking, the heating unit is working.  
- If the Heating Indicator is steady, the heating unit is not working.  
Cooling Indicator  
ROOMTHERMOSTATTEMPERATURECALIBRATION  
The devices should be placed to minimize the damage to the received and  
transmittedsignals bypayingattentiontothefollowingpoints;  
RULESTHATNEEDTOBEOBSERVEDFORSAFETY  
Temperaturesensors which areused in room thermostatsarehighly sensitive.  
You may need to calibrate your room thermostat if you would like to get the same  
temperaturevaluesasother thermometersin yourliving space.  
1- Be sureto readtheuser manual beforeusing thedeviceand itsequipment.  
2- Opening, disassembly, or use of plastic parts of the product and equipment other  
than theintended purpose areout of warranty.  
The devicesshould not be mounted on metalsurfaces.  
The devices should not be installed close to electrical cables and electronic  
equipment such ascomputers and televisionunits.  
While yourdeviceis turned off, presstheON/OFFbutton for 3 seconds.  
Press the "ON/OFF" button until the “ ” menu appears. To see the desired  
3- Please make sure that the sockets to which you connect your devices and  
equipment areattherecommendedvoltagevaluein theuser manual.  
4- Keep away and protect your product and its equipment from all kinds of external  
substances such asliquid, dust, heat, etc.  
The devices should not be installed near large metal structures or other building  
materialsusing finemetalmeshes such asspecialglass or specialconcrete.  
Distance between the room thermostat and the Receiver should not exceed 20  
metersor 2 floors.  
10  
11  
temperature, set the temperature difference by pressing the “Temperature  
AdjustmentButtons”. This valuecan be arranged between-8°C" and “+8°C".  
To save the settings and exit, press the " ON/OFF " button until the device turns  
off.  
- If the Cooling Indicator is blinking, the cooling unit is working.  
- If the Cooling Indicator is steady, the cooling unit is not working.  
5- Do not expose the device cables to any jamming and pressure. Take care to  
connect thedevices'energyconnection to thesocketsyoucan alwaysreach.  
6- Turn off the electrical power to prevent damage to your device and apparatus in  
caseof lightning and thunderstorms.  
Note: Recommended temperaturecalibration is“0.0oC”.  
The receivermustbe installed atleast50cmawayfromtheheating/cooling unit.  
Note: During active use of the room thermostat, the symbols indicated by 3, 4, 5, 6, 9,  
RECEIVERINSTALLATION  
ROOMTHERMOSTATHYSTERESISPOSITIVEMENU  
10and 11 willnot appear on thescreen.  
First, shut down your heating/cooling unit and your heating/cooling unit's power  
sourcewithallelectricalcurrent(fuse, socket, etc.)  
The hysteresis positive factory setting of your room thermostat is 0.5°C. This value  
may be adjusted between “0.1°C” and “2.0°C”. While the hysteresis positive value is  
0.5°C, if the room temperature goes above 0.5°C of the set temperature, your room  
thermostat will send a signal to your heating/cooling unit. For instance, when you  
set your room thermostat to 22.0°C, if the room temperature goes above 22.5°C, on  
the heating mode your heating unit will stop working; on the cooling mode your  
cooling unit willstart working. To change thehysteresispositivesetting:  
7- Turn off theelectricalpower when yourdeviceis not used for along time.  
8- Your devices and equipment should be used by paying attention to the matters  
stated in the user manual. In case of damage and malfunctions, arising from  
improper use (contact with liquid, falling to the ground, etc.) definitely ask for the  
installer's help.  
RECEIVER  
As shown in the connection diagram, connect one end of the heating/cooling unit  
connection cableto theCOMand theother to theNO input of thereceiver.  
Connect the other ends of the cable -which you connected to the receiver- to the  
room thermostat connection terminal as shown in your heating/cooling unit's  
user manual.  
1-Manual Operation Button:  
Deactivates the receiver and allows users to  
1
manually use the heating/cooling unit.  
2-Wi-Fi Pairing Button:  
2
9- Call our service for maintenance and repair of ARUNA 300S SMART and its  
equipment. Maintenance and repair of the device and equipment should be carried  
out only by the technical service of ISIPARK A.Ş. and its authorized services, spare  
parts, and accessoriesspecifiedbythecompany should be used.  
3
Makes the receiver ready for smart installation.  
3-Receiver LED Light  
4-Receiver Power Cable Input  
You must first connect the receiver power cable to the receiver and then to the  
fuse to which theheating/cooling unit is connected.  
While yourdeviceis turned off, pressand hold theON/OFFbutton for 3 seconds.  
PresstheON/OFFbutton until the menu appears.  
5-Heating/Cooling Unit Connection Cable Input  
Adjustthe operating sensitivitybyusing the “Up” and “Downbuttons in the “  
hysteresispositivemenu.  
After completing the cable connection process, first, turn on your fuse and then  
yourheating/cooling unit.  
ARUNA 300SSMARTandEQUIPMENT  
To savethesettingsand exit, pressthe"ON/OFF"button until thedeviceturns off.  
Changes have been saved. Your room thermostat will be working with set  
operating sensitivitywhen youopen yourdevice.  
Finish the installation of the room thermostat to pair the receiver with the room  
thermostat.  
ARUNA 300S SMART  
Room Thermostat  
Holder Alkaline  
Battery  
Receiver  
Dowels and  
Screws  
AC  
(230V)  
RECEIVERWIRINGDIAGRAM  
COM  
NO  
4
5
ROOMTHERMOSTATHYSTERESISNEGATIVEMENU  
RECEIVERLEDDESCRIPTIONS  
The hysteresis negative factory setting of your room thermostat is -0.5°C. This  
value may be adjusted between “-0.1°C” and “-2.0°C”. While the hysteresis negative  
value is -0.5°C, if the room temperature goes below 0.5°C of the set temperature,  
your room thermostat will send a signal to your heating/cooling unit. For instance,  
when you set your room thermostat to 22°C, if the room temperature goes below  
21.5°C, on the heating mode your heating unit will start working; on the cooling  
mode your cooling unit will stop working. To change the hysteresis negative  
setting:  
Blinking Red  
The receiver did not get any signal from the heating/  
cooling unit for 22 minutes or longer and the heating/  
cooling unit has shut down.  
TECHNICALDATA  
Room Thermostat  
Fast Blinking Red  
Steady Red  
Waiting for a pairing signal from the room thermostat.  
The receiver and the room thermostat have been paired.  
Smart installation has not been completed.  
The receiver is in Bluetooth searching mode.  
Smart installation has been completed.  
The heating/cooling unit is not working.  
The heating/cooling unit is working.  
Dimensions (H/L/W)  
Operating Current  
Temperature Measurement Accuracy  
Operating Sensitivity  
Operating Temperature Range  
Battery Life  
85mm / 125mm / 20mm  
3V DC (2 x AAA Alkaline Battery)  
Blinking Green  
Steady Green  
0.1oC  
(-2.0oC) – (+2.0oC)  
(5oC) – (40oC)  
1 Year (2 x AAA)  
(-10oC) – (+50oC)  
(-20oC) – (+60oC)  
While yourdeviceis turned off, pressand hold theON/OFFbutton for 3 seconds.  
PresstheON/OFFbutton until the menu appears.  
HEATING/COOLING UNIT  
Steady Turquoise  
3 Short Red Blinking  
Shut the heating/cooling unit down signal has reached  
the receiver.  
Warning! Operations within the heating/cooling unit or the electrical installation  
Adjustthe operating sensitivitybyusing the “Up” and “Downbuttons in the “  
hysteresisnegativemenu.  
Operating Temperature  
Storage Temperature  
must be carriedout byprofessionally qualified persons.  
3 Short Green Blinking  
Operate the heating/cooling unit signal has reached the  
receiver.  
To savethesettingsand exit, pressthe"ON/OFF"button until thedeviceturns off.  
Changes have been saved. Your room thermostat will be working with set  
operating sensitivitywhen youopen yourdevice.  
Receiver  
PAIRINGTHEROOMTHERMOSTATWITHTHERECEIVER  
Blinking Red and Green The heating/cooling unit is working in manual mode.  
To pair the room thermostat with the receiver, press the “Manual Operation  
Button” and “Wi-Fi Pairing Button” together at the same time and see the  
receiver's fastblinking redLED.  
Dimensions (H/L/W)  
Operating Current  
Relay NO Switching Current  
90mm / 90mm / 25mm  
230V AC  
7A (240VAC – Resistive Load)  
10A (120VAC – Resistive Load)  
(-20oC) – (+60oC)  
ROOMTHERMOSTATPLACEMENT  
The room thermostat needs to be placed in the room which is used most frequently.  
For instance; the living room or lounge. Placing the room thermostat in a spot that  
has air circulation like the entrance of a room or the side of the window should be  
avoided. Also anywhereclose to heating/cooling units such as a radiator, stove, and  
spots that get directsun lights would not be suitable. The roomthermostat needs to  
be located abovethe floor 150 cm in height. Few trials may be made to find the most  
convenientspot.  
PresstheON/OFFbutton for 3 seconds while yourdeviceis turned off.  
PresstheON/OFFbutton until “  
Storage Temperature  
” thepairing menu appears.  
Press your room thermostat's “Up” or “Down“ button while the LED is fast blinking  
red.  
Ifthepairing is successful, thefastredashing LEDon thereceiverwillbe steady.  
The receiverand room thermostathavebeen pairedwitheachother.  
1
2
3
4
GeneralDetails
NameGENERAL ARUNA 300S Smart Room Thermostat User Manual
MakeGENERAL
LanguageEnglish
FiletypePDF (Download)
File size2.17 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
GENERAL HT250S Digital Room Thermostat User Manual
GENERAL HT250S Digital Room Thermostat User Manual
GENERAL FH260S Underfloor Heating Thermostat User Manual
GENERAL FH260S Underfloor Heating Thermostat User Manual
GENERAL HT100S Digital Room Thermostat User Manual
GENERAL HT100S Digital Room Thermostat User Manual
GENERAL SOLARA 330S SMART Smart Room Thermostat User Manual
GENERAL SOLARA 330S SMART Smart Room Thermostat User Manual
GENERAL HT250 Digital Room Thermostat User Manual
GENERAL HT250 Digital Room Thermostat User Manual
GENERAL SENNA 300 Digital Room Thermostat User Manual
GENERAL SENNA 300 Digital Room Thermostat User Manual
GENERAL ARUNA 300S RF Digital Room Thermostat User Manual
GENERAL ARUNA 300S RF Digital Room Thermostat User Manual
GENERAL SENNA 300 Smart Room Thermostat User Manual
GENERAL SENNA 300 Smart Room Thermostat User Manual
GENERAL MITRA 250S Digital Room Thermostat User Manual
GENERAL MITRA 250S Digital Room Thermostat User Manual
GENERAL MITRA 220 RF Digital Room Thermostat User Manual
GENERAL MITRA 220 RF Digital Room Thermostat User Manual

GENERAL ARUNA 300S Smart Room Thermostat User Manual
Get the free PDF manual for the GENERAL ARUNA 300S Smart Room Thermostat User Manual and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

GENERAL ARUNA 300S Smart Room Thermostat User Manual Overview

Summary of Contents

  • Page 1: Smart room thermostat is a device that allows you to control your heating equipment via an app with the internet even when you are not at home. For smart receiver setup, download the Smart Life application from App Store or Google Play or scan the QR code with your smartphone. Insert 2 new AAA alkaline batteries in the battery housing with the correct battery direction. You can control your home's temperature via its mobile application, no matter where you are in the world. You can easily create daily and weekly schedules via its mobile application. The important things to note for the receiver placement are avoiding physical contact between the receiver and the heating/cooling unit, and protecting it against materials such as liquid, dust, etc. Temperature sensors used in room thermostats are highly sensitive. The hysteresis positive factory setting of your room thermostat is 0.5°C. The hysteresis negative factory setting of your room thermostat is -0.5°C. The room thermostat needs to be placed in the room which is used most frequently.
  • Page 2: open window detection feature When the product is not used for a long period (more than 15 days), remove the batteries. Your room thermostat measures sudden temperature changes in your house with its open window detection feature and prevents unnecessary energy consumption by turning off the heating/cooling unit. Damages that may occur during the transportation of devices and apparatus are not covered by the warranty. The room thermostat is switched to heating mode while the detection is active. Devices and apparatuses are out of warranty for malfunctions caused by force majeure such as fire, flood, earthquake, etc. The heating unit remains switched off for 10 minutes unless manual intervention is performed on the room thermostat. In order to set the weekly schedule, press and hold the “Weekly Program“ button for 3 seconds while your Room Thermostat is on. In case of malfunction of the devices and apparatuses within the warranty period, the time spent during repairment period is added to the warranty period. The warranty document must be kept by the customer during the warranty period.