GENERAL 270 RF Room Thermostat Instruction Manual
AC
ScreenIndicators
RECEIVER WIRING DIAGRAM
ENGLISH
COM
NO
(230V)
5
DIGITAL ROOM THERMOSTAT
6
7
1
2
generallife.com.tr
BATTERY PLACEMENT
3
4
SENNA 270 RF USER MANUAL
HEATING/COOLING UNIT
GENERAL SPECIFICATIONS
1
2
3
4
5
Room Temperature
SENNA270RFisawirelessroom thermostat. Theusercanadjustthe
room temperaturewiththerequiredtemperatureand getmore
comfortable and economic heating/cooling.
DifferentModeOptions (Comfort Modeand Economy Mode)
PreciseTemperatureMeasurement
Heating Calibration
Warning!
Set Temperature
Economy Mode
Comfort Mode
Operations within the heating / cooling unit or the electrical installation
mustbecarriedout byprofessionally qualifiedpersons.
Battery Indicator
Heating Indicator
PAIRING THE ROOM THERMOSTAT AND THE RECEIVER
ON/OFFControl
WirelessConnection
TPIAlgorithm
6
- If the Heating Indicator is blinking, the heating unit is working.
- If the Heating Indicator is steady, the heating unit is not working.
Cooling Indicator
Primarily press the sync button of receiver for 2 seconds and see blinking
greenlight of receiver.
While your device is turned off, press and hold the "On/Off"button for 3
seconds.
Heating/Cooling Modes
7
- If the Cooling Indicator is blinking, the cooling unit is working.
- If the Cooling Indicator is steady, the cooling unit is not working.
As shown in the picture above, press the screwdriverforward from the space
shown, bend the tabs and separate the front cover. Insert 2 new AAA alkaline
batteries in the battery housing with the correct battery direction. Replace
both batteries at the same time. Then align the front part of your Room
Thermostattothebackand squeezeittowardstheback.
SENNA 270 RF AND EQUIPMENTS
Pressthebutton until the“
Press the "+" or "-" button of your Room Thermostat while the LED is
flashing green.
If the pairing is successful, the green flashing LED on the receiver will be
constant.
Receiverand Room Thermostathavebeenpairedtoeachother.
”menu appears.
SENNA 270 RF Room Thermostat
Holder
Alkaline
Battery
RECEIVER
1-Manual Operation Button:
By disabling the Receiver, it enables you to
use your boiler manually.
1
2
3
Low Battery Warning: When the “
” icon appears on the screen, it means
“low battery warning”. It is recommended to replace the batteries when this
warning appears.
Warning: When the product is not used for a long period (more than 15 days),
remove the batteries. Otherwise, malfunctions that may occur would be out of
warranty.
2-Pairing Button:
Allows to pair the Receiver with the Room
Thermostat.
3-Receiver LED Light
4-Receiver Power Cable Input
5-Boiler Connection Cable Input
Dowels and Screws
Receiver
ROOM THERMOSTATTEMPERATURE CALIBRATION
Temperature sensors which are used in Room Thermostats are highly
sensitive. You mayneed to calibrate yourRoom Thermostat if youwould like
to get the same temperature values with other thermometers in your living
space.
Pleasethrowyourdead batteriesinto thewastebin forbatteries.
RECEIVER PLACEMENT
While your device is turned off, press and hold the "On/Off"button for 3
seconds.
Press the "On/Off" button until the “
desired temperature, set the temperature difference by press the
“Temperature Adjustment Buttons”. This value can be arranged between
“-8oC" and “+8oC".
To save the settings and exit, press the "On/Off" button until the device
turnsoff.
The important things to note for the Receiver
placement is avoiding physical contact between the
Receiver and heating/cooling unit, and protecting it
againstmaterialssuch asliquid, dustetc.
4
5
” menu appers. In order to see the
TECHNICAL DATA
Room Thermostat
RECEIVER LED DESCRIPTIONS
Steady Red
Dimensions
85mm / 125mm / 19mm
3V DC (2 x AAA alkaline battery)
Receiver has power but Receiver and
Operating Current
Room Thermostat are not paired.
Waiting for pairing signal from Room Thermostat.
Receiver and Room Thermostat are paired.
Boiler is not operating.
Temperature Measurement Accuracy 0.1oC
Blinking Green
Steady Green
Operating Temperature Range
Battery Life
(5oC) – (30oC)
1 Years (2 x AAA)
(-10oC) – (+50oC)
(-20oC) – (+60oC)
The devices should be placed in order to minimize the damage to the
receivedandtransmittedsignals bypayingattentiontothefollowingpoints;
Note:Recommended tempreturecalibrationis“0.0oC”.
Operating Temperature
Storage Temperature
Thedevicesshould notbemounted on metalsurfaces.
The devices should not be installed close to electrical cables and
electronic equipment such ascomputersand televisionunits.
The devices should not be installed near large metal structures or other
building materials using fine metal meshes such as special glass or
specialconcrete.
3 Short Orange
Blinking
Operate the boiler signal has reached to the
Receiver.
FACTORY SETTINGS RESET
You can reset your Room Thermostat to its default factory settings. This
operation resets the mode temperature values, calibration setting and
heating/coling modes to factory setting. To reset your Room Thermostat to
factory setting:
Steady Orange
3 Short Green
Blinking
Boiler is operating.
Receiver
Dimensions
Operation Current
Relay NO Switching Current
Shut the boiler down signal has reached to the
Receiver.
90mm / 90mm / 25mm
230V AC
7A (240VAC – Resistive load)
10A (120VAC – Resistive load)
(-20oC) – (+60oC)
Blinking Orange
Boiler is operating in manual mode.
While your device is turned off, press and hold the "On/Off"button for 3
seconds.
Pressthe“On/Off” button until “
While in the “ ” menu, select the “ ” option by using “+” or “-” buttons
and pressthe“On/Off” button.
Distance between the Room Thermostat and the Receiver should not
exceed20metersor2floors.
Receiver must be installed at least 50 cm away from the heating/cooling
unit.
Blinking Red
Receiver did not get a signal from the
Room Thermostat for 22 minutes or longer and
boiler has shut down.
Storage Temperature
”menu appears.
ROOM THERMOSTAT
ButtonsFunctions
ROOM THERMOSTAT PLACEMENT
Your devicewillbeturnedoff and resettofactory settings.
RECEIVER SETUP
Room Thermostat needs to be placed in the room which is used most
frequently. For instance; living room or lounge. Placing the Room
Thermostat in a spot that have air circulation like entrance of a room or side
of window should be avoided. Also anywhere close to heating/cooling units
such as radiator, stove and spots which get direct sun lights would not be
suitable. Room Thermostat needs to be located above the floor 150 cm
height. Fewtrialsmaybemadetofindthemostconvenientspot.
First, shut down your heating/cooling unit and your heating/cooling unit's
powersourcewithallelectricalcurrent(fuse, socketetc.)
As shown in the connection diagram, connect one end of the
heating/cooling unit connection cable to the COM and the other to the NO
input of theReceiver.
MODE SETTINGS
There are 2 modes in the Room Thermostat. These are Comfort Mode “
and Economy Mode “ ”. Modes work according to the pre-set temperature
valuesadjustedbyuser.
Inordertochange thecomfort mode temperaturevalue;
1
”
2
3
Connect the other ends of the cable -which you connected to the Receiver
to room thermostat connection terminal as shown in your
heating/cooling unit'susermanual.
4
Pressand hold thecomfort mode button for3seconds.
Change thetemperaturevaluebypressing “+” or“-“ buttons.
Press the comfort mode button once to save the changes you have made
orwait10seconds.
You must first connect the Receiver power cable to the Receiver and then
tothefusetowhich theheating/cooling unitisconnected.
After completing the cable connection process, firstly turn on your fuse
and thenyourheating/cooling unit.
By pressing the Receiver's manual usage button for 2 seconds, youshould
see the Orange Light blinking on the Receiver. In this way, after making
sure that the heating/cooling unit is operating, press the same button
again for2seconds and seethattheOrangeLEDturnsoff.
Set up the Room Thermostat to pair the Receiver with the Room
Thermostat.
5
6
Inordertochange theeconomy mode temperaturevalue;
1
2
3
4
5
6
ON/OFF and Setting Button
Pressand hold theeconomy mode button for 3seconds.
Change thetemperaturevaluebypressing “+” or“-” buttons.
Press the economy mode button once to savethe changes youhavemade
orwait10seconds.
Economy Mode
Comfort Mode
Heating/Cooling Modes (Press and hold for 5 seconds.)
Temperature Adjustment (Increasing)
Temperature Adjustment (Decreasing)
You canusethe“+” and “-” buttons tousetheRoomThermostatmanually.
1
2
3
4
| General | Details |
|---|---|
| Name | GENERAL 270 RF Room Thermostat Instruction Manual |
| Make | GENERAL |
| Language | English |
| Filetype | PDF (Download) |
| File size | 2.06 MB |

GENERAL ARUNA 300S Smart Room Thermostat User Manual

GENERAL HT250S Digital Room Thermostat User Manual

GENERAL FH260S Underfloor Heating Thermostat User Manual

GENERAL HT100S Digital Room Thermostat User Manual

GENERAL SOLARA 330S SMART Smart Room Thermostat User Manual

GENERAL HT250 Digital Room Thermostat User Manual

GENERAL ARUNA 300S RF Digital Room Thermostat User Manual

GENERAL SENNA 300 Digital Room Thermostat User Manual

GENERAL SENNA 300 Smart Room Thermostat User Manual

GENERAL MITRA 250S Digital Room Thermostat User Manual















