Home > GENERAL > GENERAL 270 RF Room Thermostat Instruction Manual

GENERAL 270 RF Room Thermostat Instruction Manual

AC  
ScreenIndicators  
RECEIVER WIRING DIAGRAM  
ENGLISH  
COM  
NO  
(230V)  
5
DIGITAL ROOM THERMOSTAT  
6
7
1
2
generallife.com.tr  
BATTERY PLACEMENT  
3
4
SENNA 270 RF USER MANUAL  
HEATING/COOLING UNIT  
GENERAL SPECIFICATIONS  
1
2
3
4
5
Room Temperature  
SENNA270RFisawirelessroom thermostat. Theusercanadjustthe  
room temperaturewiththerequiredtemperatureand getmore  
comfortable and economic heating/cooling.  
DifferentModeOptions (Comfort Modeand Economy Mode)  
PreciseTemperatureMeasurement  
Heating Calibration  
Warning!  
Set Temperature  
Economy Mode  
Comfort Mode  
Operations within the heating / cooling unit or the electrical installation  
mustbecarriedout byprofessionally qualifiedpersons.  
Battery Indicator  
Heating Indicator  
PAIRING THE ROOM THERMOSTAT AND THE RECEIVER  
ON/OFFControl  
WirelessConnection  
TPIAlgorithm  
6
- If the Heating Indicator is blinking, the heating unit is working.  
- If the Heating Indicator is steady, the heating unit is not working.  
Cooling Indicator  
Primarily press the sync button of receiver for 2 seconds and see blinking  
greenlight of receiver.  
While your device is turned off, press and hold the "On/Off"button for 3  
seconds.  
Heating/Cooling Modes  
7
- If the Cooling Indicator is blinking, the cooling unit is working.  
- If the Cooling Indicator is steady, the cooling unit is not working.  
As shown in the picture above, press the screwdriverforward from the space  
shown, bend the tabs and separate the front cover. Insert 2 new AAA alkaline  
batteries in the battery housing with the correct battery direction. Replace  
both batteries at the same time. Then align the front part of your Room  
Thermostattothebackand squeezeittowardstheback.  
SENNA 270 RF AND EQUIPMENTS  
Pressthebutton until the“  
Press the "+" or "-" button of your Room Thermostat while the LED is  
flashing green.  
If the pairing is successful, the green flashing LED on the receiver will be  
constant.  
Receiverand Room Thermostathavebeenpairedtoeachother.  
menu appears.  
SENNA 270 RF Room Thermostat  
Holder  
Alkaline  
Battery  
RECEIVER  
1-Manual Operation Button:  
By disabling the Receiver, it enables you to  
use your boiler manually.  
1
2
3
Low Battery Warning: When the “  
” icon appears on the screen, it means  
“low battery warning”. It is recommended to replace the batteries when this  
warning appears.  
Warning: When the product is not used for a long period (more than 15 days),  
remove the batteries. Otherwise, malfunctions that may occur would be out of  
warranty.  
2-Pairing Button:  
Allows to pair the Receiver with the Room  
Thermostat.  
3-Receiver LED Light  
4-Receiver Power Cable Input  
5-Boiler Connection Cable Input  
Dowels and Screws  
Receiver  
ROOM THERMOSTATTEMPERATURE CALIBRATION  
Temperature sensors which are used in Room Thermostats are highly  
sensitive. You mayneed to calibrate yourRoom Thermostat if youwould like  
to get the same temperature values with other thermometers in your living  
space.  
Pleasethrowyourdead batteriesinto thewastebin forbatteries.  
RECEIVER PLACEMENT  
While your device is turned off, press and hold the "On/Off"button for 3  
seconds.  
Press the "On/Off" button until the “  
desired temperature, set the temperature difference by press the  
“Temperature Adjustment Buttons”. This value can be arranged between  
“-8oC" and “+8oC".  
To save the settings and exit, press the "On/Off" button until the device  
turnsoff.  
The important things to note for the Receiver  
placement is avoiding physical contact between the  
Receiver and heating/cooling unit, and protecting it  
againstmaterialssuch asliquid, dustetc.  
4
5
” menu appers. In order to see the  
TECHNICAL DATA  
Room Thermostat  
RECEIVER LED DESCRIPTIONS  
Steady Red  
Dimensions  
85mm / 125mm / 19mm  
3V DC (2 x AAA alkaline battery)  
Receiver has power but Receiver and  
Operating Current  
Room Thermostat are not paired.  
Waiting for pairing signal from Room Thermostat.  
Receiver and Room Thermostat are paired.  
Boiler is not operating.  
Temperature Measurement Accuracy 0.1oC  
Blinking Green  
Steady Green  
Operating Temperature Range  
Battery Life  
(5oC) – (30oC)  
1 Years (2 x AAA)  
(-10oC) – (+50oC)  
(-20oC) – (+60oC)  
The devices should be placed in order to minimize the damage to the  
receivedandtransmittedsignals bypayingattentiontothefollowingpoints;  
Note:Recommended tempreturecalibrationis0.0oC”.  
Operating Temperature  
Storage Temperature  
Thedevicesshould notbemounted on metalsurfaces.  
The devices should not be installed close to electrical cables and  
electronic equipment such ascomputersand televisionunits.  
The devices should not be installed near large metal structures or other  
building materials using fine metal meshes such as special glass or  
specialconcrete.  
3 Short Orange  
Blinking  
Operate the boiler signal has reached to the  
Receiver.  
FACTORY SETTINGS RESET  
You can reset your Room Thermostat to its default factory settings. This  
operation resets the mode temperature values, calibration setting and  
heating/coling modes to factory setting. To reset your Room Thermostat to  
factory setting:  
Steady Orange  
3 Short Green  
Blinking  
Boiler is operating.  
Receiver  
Dimensions  
Operation Current  
Relay NO Switching Current  
Shut the boiler down signal has reached to the  
Receiver.  
90mm / 90mm / 25mm  
230V AC  
7A (240VAC – Resistive load)  
10A (120VAC – Resistive load)  
(-20oC) – (+60oC)  
Blinking Orange  
Boiler is operating in manual mode.  
While your device is turned off, press and hold the "On/Off"button for 3  
seconds.  
PresstheOn/Off” button until “  
While in the “ ” menu, select the “ ” option by using “+” or “-” buttons  
and presstheOn/Off” button.  
Distance between the Room Thermostat and the Receiver should not  
exceed20metersor2oors.  
Receiver must be installed at least 50 cm away from the heating/cooling  
unit.  
Blinking Red  
Receiver did not get a signal from the  
Room Thermostat for 22 minutes or longer and  
boiler has shut down.  
Storage Temperature  
menu appears.  
ROOM THERMOSTAT  
ButtonsFunctions  
ROOM THERMOSTAT PLACEMENT  
Your devicewillbeturnedoff and resettofactory settings.  
RECEIVER SETUP  
Room Thermostat needs to be placed in the room which is used most  
frequently. For instance; living room or lounge. Placing the Room  
Thermostat in a spot that have air circulation like entrance of a room or side  
of window should be avoided. Also anywhere close to heating/cooling units  
such as radiator, stove and spots which get direct sun lights would not be  
suitable. Room Thermostat needs to be located above the floor 150 cm  
height. Fewtrialsmaybemadetondthemostconvenientspot.  
First, shut down your heating/cooling unit and your heating/cooling unit's  
powersourcewithallelectricalcurrent(fuse, socketetc.)  
As shown in the connection diagram, connect one end of the  
heating/cooling unit connection cable to the COM and the other to the NO  
input of theReceiver.  
MODE SETTINGS  
There are 2 modes in the Room Thermostat. These are Comfort Mode “  
and Economy Mode “ ”. Modes work according to the pre-set temperature  
valuesadjustedbyuser.  
Inordertochange thecomfort mode temperaturevalue;  
1
2
3
Connect the other ends of the cable -which you connected to the Receiver  
to room thermostat connection terminal as shown in your  
heating/cooling unit'susermanual.  
4
Pressand hold thecomfort mode button for3seconds.  
Change thetemperaturevaluebypressing “+” or-“ buttons.  
Press the comfort mode button once to save the changes you have made  
orwait10seconds.  
You must first connect the Receiver power cable to the Receiver and then  
tothefusetowhich theheating/cooling unitisconnected.  
After completing the cable connection process, firstly turn on your fuse  
and thenyourheating/cooling unit.  
By pressing the Receiver's manual usage button for 2 seconds, youshould  
see the Orange Light blinking on the Receiver. In this way, after making  
sure that the heating/cooling unit is operating, press the same button  
again for2seconds and seethattheOrangeLEDturnsoff.  
Set up the Room Thermostat to pair the Receiver with the Room  
Thermostat.  
5
6
Inordertochange theeconomy mode temperaturevalue;  
1
2
3
4
5
6
ON/OFF and Setting Button  
Pressand hold theeconomy mode button for 3seconds.  
Change thetemperaturevaluebypressing “+” or-” buttons.  
Press the economy mode button once to savethe changes youhavemade  
orwait10seconds.  
Economy Mode  
Comfort Mode  
Heating/Cooling Modes (Press and hold for 5 seconds.)  
Temperature Adjustment (Increasing)  
Temperature Adjustment (Decreasing)  
You canusethe+” and “-” buttons tousetheRoomThermostatmanually.  
1
2
3
4
GeneralDetails
NameGENERAL 270 RF Room Thermostat Instruction Manual
MakeGENERAL
LanguageEnglish
FiletypePDF (Download)
File size2.06 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
GENERAL ARUNA 300S Smart Room Thermostat User Manual
GENERAL ARUNA 300S Smart Room Thermostat User Manual
GENERAL HT250S Digital Room Thermostat User Manual
GENERAL HT250S Digital Room Thermostat User Manual
GENERAL FH260S Underfloor Heating Thermostat User Manual
GENERAL FH260S Underfloor Heating Thermostat User Manual
GENERAL HT100S Digital Room Thermostat User Manual
GENERAL HT100S Digital Room Thermostat User Manual
GENERAL SOLARA 330S SMART Smart Room Thermostat User Manual
GENERAL SOLARA 330S SMART Smart Room Thermostat User Manual
GENERAL HT250 Digital Room Thermostat User Manual
GENERAL HT250 Digital Room Thermostat User Manual
GENERAL SENNA 300 Digital Room Thermostat User Manual
GENERAL SENNA 300 Digital Room Thermostat User Manual
GENERAL ARUNA 300S RF Digital Room Thermostat User Manual
GENERAL ARUNA 300S RF Digital Room Thermostat User Manual
GENERAL SENNA 300 Smart Room Thermostat User Manual
GENERAL SENNA 300 Smart Room Thermostat User Manual
GENERAL MITRA 250S Digital Room Thermostat User Manual
GENERAL MITRA 250S Digital Room Thermostat User Manual

GENERAL 270 RF Room Thermostat Instruction Manual
Get the free PDF manual for the GENERAL 270 RF Room Thermostat Instruction Manual and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

GENERAL 270 RF Room Thermostat Instruction Manual Overview

Summary of Contents

  • Page 1: AC screen indicators Receiver wiring diagram Digital room thermostat Battery placement Senna 270 RF user manual General specifications Room temperature Senna 270 RF is a wireless room thermostat that allows users to adjust the room temperature for more comfortable and economic heating/cooling. Different mode options include comfort mode and economy mode. Temperature sensors in room thermostats are highly sensitive and may require calibration for accurate readings.
  • Page 2: warranty conditions The warranty period starts from the invoice date and is warranted against manufacturing defects for 5 years. warranty certificate Your room thermostat sends the last status signal to the receiver every 6 minutes, ensuring synchronous operation. If the signal cannot reach the receiver for 22 minutes, it stops the heating/cooling operation for safety reasons. TPI technology TPI technology is designed to ensure optimal energy efficiency from your heating/cooling system by predicting temperature changes and adjusting operations accordingly. maintenance and repair Devices and apparatus are delivered in working condition. On-site commissioning is subject to a service fee, and repairs covered by the warranty are carried out at the company factory. malfunctioning devices In case of malfunctioning devices under warranty, the cause will be tested, and if it's a manufacturer fault, repair or replacement can be requested at no cost. customer responsibilities Customers must report any damages to the manufacturer from the start of the warranty period to retain their rights. exclusions from warranty Malfunctions due to improper use, external damages, or use of devices from other brands are not covered by the warranty. battery maintenance When the product is not used for more than 15 days, batteries should be removed to avoid malfunctions that will be out of warranty. complaints and appeals Customers can make complaints to consumer courts or arbitration committees, and the warranty document must be kept during the warranty period. product specifications Isıpark reserves the right to change product specifications and user manuals.