Home > InfraComfort > InfraComfort HY01WE Programmable Non Wi-Fi Thermostat User Manual
InfraComfort HY01WE Programmable Non Wi-Fi Thermostat User Manual
Monday to
Friday
the default
value
20°C
Saturday and
Sunday
the default
value
20°C
Interval
Infracomfort HY01WE Thermostat User Manual
Many thanks for your selection of our products and services, and also for your trust and support to us
1st
2nd
3rd
4th
5th
6th
06:00-08:00
08:00-11:30
11:30-13:30
13:30-17:00
17:00-22:00
22:00-06:00
06:00-08:00
08:00-11:30
11:30-13:30
13:30-17:00
17:00-22:00
22:00-06:00
15°C
15°C
15°C
22°C
15°C
15°C
15°C
22°C
15°C
15°C
Mode
explain
”to switch into programme mode (As shown in
printscreen
Press“
picture one)
Programme illustration
5+2 programme function(advanced options contain of
6+1 and 7 days programme function, you can also cancel
this programme function), that is Monday to Friday is the
same setting value, and Saturday to Sunday is the same
setting value。Every day can be divided into 6 time
interval
Programming
mode
Product Specification
☆ Power: 100-240V 50/60Hz(WE,WW)
two AA* 1.5V alkaline batteries(BW)
☆ Range of temperature display: 0~40°C/32~104°F
☆ Insulating condition: Normal environment
☆ Running program: Set per 1 week as a cycle
☆ Installation: Wall mounted or on battery seat
☆ Range of temperature adjustment: 5~35°C/41~95°F
☆ Display accuracy: 0.5°C or 1°F
Setting the programme value:long press“
” to enter
”to
into programme setting mode, then short press“
switch, press“ ”or“ ”to adjust value.
☆ Output: Switch relay
☆ Probe sensor: NTC(10k)1%
☆ Size(mm): 130*90*27 And 107*78*28
☆ Contact capacity: 16A(electric heating)
3A(water heating)
☆ Working environment temperature: 0~70°C/32~122°F
Press “
” to enter into manual mode (As shown in
”or“ ”to adjust value.
5A(gas boiler heating)
picture two), press“
Manual Mode
Displays & Buttons
at programme mode,press “ ” or “
value, it will automatic enter into temporary manual
mode
” to adjust the
Temporary
manual mode
Advanced Options
Advanced options can be classified to two sets
MODE 1:
Turn off thermostat,long press
for 3 seconds,it will display A01-A09,then press
Press“ ”or“ ”to adjust value
to switch between these options
Display
Option content
symbol
temperature
compensation(
A01)
Press “
”or“ ” key to adjust setting value (—9~9 ) increment:0.5°C.
Operation Key
NO:
symbols
represent
set key: short press it to switch programme mode to manual mode. At programme mode,
press “ ”or” ” to adjust the value, it will automatic enter into temporary manual mode
Increasing key
Range:1°C~5°C:
A
1.When the setting temperature is higher than or equal to the sum of indoor
temperature and the start differential temperature, the heating equipment will
turn on.
2.When the indoor temperature is higher than or equal to the sum of the setting
temperature and the start differential temperature, the heating equipment will
turn off.
B
Start differential
temperature(A02
)
clock key: short pressing is setting clock, long pressing is setting programme
C
Keys locked/unlocked:press “ ”and“ ”at the same time for 3 seconds
D
E
Decreasing key
Power on/off key
0 half locked:all keys are locked except for the on-off key;
1 full locked,all keys are locked including the on-off key.
Keypad (A03)
Run Mode
Factory Preset Mode
N1:single build-in sensor;
N2:single build-out sensor;
N3:build-in and build-out sensor
Sensor choice(
A04)
| General | Details |
|---|---|
| Name | InfraComfort HY01WE Programmable Non Wi-Fi Thermostat User Manual |
| Make | InfraComfort |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.18 MB |

Infracomfort HY312W Wifi Digital Thermostat User Manual

InfraComfort HY01WE Programmable Non Wi-Fi Thermostat User Manual Overview
Summary of Contents
- Page 1: Interval settings for weekdays and weekends default to 20°C. The Infracomfort HY01WE thermostat features a 5+2 program function for scheduling. Each day can be divided into six time intervals for temperature adjustments. The product operates on a power range of 100-240V and requires two AA batteries. Temperature display ranges from 0°C to 40°C, with an adjustment range of 5°C to 35°C. The thermostat can be wall-mounted or placed on a battery seat. Manual mode can be accessed by pressing a specific button combination. Advanced options include temperature compensation and sensor selection. The operation keys allow for easy switching between program and manual modes. The device features a factory preset mode with options for different sensor configurations.
- Page 2: LCD panel and power panel should be connected softly to avoid line breakage. LCD panel also needs to be connected to the hidden box. Press the cover softly to complete the installation. High temperature protection function is canceled when the indoor temperature exceeds the set high temperature. Default high temperature protection value is 45°C. Low temperature protection function is canceled when the indoor temperature is below the set low temperature. Default low temperature protection value is 5°C. Temperature highest limiting value range is 1°C to 10°C. Temperature lowest limiting value range is 30°C to 70°C. Anti-freezing function opens the valve for 3 minutes if it has been closed for over 100 hours.