Smart Zoning System  
Table 3. Humidity Control Modes of Operations  
NOTE: Lennox Smart Zoning Control only functions with Lennox  
Setting  
communicating systems.  
Description  
Mode  
IMPORTANT  
The Lennox Smart Room Sensor is not compatible with systems using the  
Lennox Smart Zoning System (iHarmony).  
dehumidification set−point  
48%  
For user setting options, go to Menu > Settings > Zoning Control. By  
default Zoning is ON on the Zoning Control screen. If the homeowner wishes  
to place the system into central mode, then this setting must be OFF. Each  
zone can be renamed on this screen.  
40%  
60%  
Heating / Cooling Changeover  
The following is an example of how the zoning system operates during a  
heating / cooling changeover.  
humidification set−point + dehumification set−point  
When the system is satisfying a call from zone 1 for heating and receives a call  
for cooling from zone 2, the following will occur:  
40%  
48%  
15%  
60%  
The system will continue to fulfill the demand from zone 1 until satisfied or a  
maximum time of 20 minutes has been reached.  
If after 20 minutes the system is still operating based on satisfying the heating  
demand from zone 1, the system will terminate that demand.  
The system will then shut system down for five (5) minutes. This allows for  
system temperatures and operating pressures to stabilize.  
Dew point adjustment mode will change the humidification set  
point based on the outdoor temperature and a user-defined dew  
point adjustment setting.  
After a five (5) minute delay the system will begin operations to satisfy the  
cooling demand from zone 2.  
NOTE: Dew Point - Adjustment requires an outdoor  
temperature sensor and is automatically controlled by  
the outside temperature.  
The system will continue to operate in this manner each time it receives a zone  
call that is opposite of the current mode of operation (heating or cooling).  
dew point  
on  
0%  
Cooling Operation  
−15%  
15%  
When a zone thermostat makes a demand for cooling, the zone damper opens  
and the cooling equipment begins operating.  
Cooling demand is terminated when:  
Dehumidification Accessory Installed  
» All zone demands for cooling are terminated.  
When either an Auxiliary Dehumidifier or Humiditrol equipment is installed  
the settings available are Off and Dehumidify. When Dehumidify is selected  
a Dehumidification Set-Point adjustment tool is available and allows  
adjustments between 50% to 60%.  
» The demand has exceeded the Heat • Cool changeover time limit (20  
minutes) while a heat demand exists.  
When cooling demand is terminated, a five minute minimum off time delay is  
initiated. Second stage cooling is energized when the discharge air temperature  
is 7°F higher than the set point of the cooling staging temperature settings.  
35  
GeneralDetails
NameLENNOX S40 Smart Thermostat User Guide
MakeLennox
LanguageEnglish
FiletypePDF (Download)
File size1.3 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
LENNOX L40 Smart Thermostat Owner’s Manual
LENNOX L40 Smart Thermostat Owner’s Manual
LENNOX EL18KCV Smart Wi-Fi Communicating Thermostat User Manual
LENNOX EL18KCV Smart Wi-Fi Communicating Thermostat User Manual

LENNOX S40 Smart Thermostat User Guide