Secure ThermoPlus PRT1 Manual: Questions and Answers
Secure ThermoPlus PRT1 specifications
| Maximum load | 3(1)Amps (230 V AC) |
| Setpoint range | 5˚C - 30˚C (1˚C Steps) |
| Differential | <0.5˚C (At 4˚C/hour) |
What fuse rating does the Secure ThermoPlus PRT1 require?
3 Amp fused spur. Instruction Manual, p. 5
What do the Warm/Cool button and temperature adjustment buttons do on the Secure ThermoPlus PRT1?
The centre button toggles between warm and cool modes. Red lights indicate warm mode; use '+' to increase temperature or '-' to decrease it. Blue light indicates cool mode; temperature buttons don't work when blue is on. Instruction Manual, p. 7
How do I reset the Secure ThermoPlus PRT1 to factory settings?
Press the UP and DOWN arrow buttons together, then release them.
- Press the UP and DOWN arrow buttons simultaneously.
- Release the buttons; the thermostat returns to preset factory settings and time defaults to 1st January 2005. Instruction Manual, p. 6
What does the flashing display mean on Secure ThermoPlus during time setup?
The display flashes each component in sequence: minute, then hour, then date, then month, then year. Adjust each using the Up/down buttons, pressing Set to move to the next component. Instruction Manual, p. 9
Can I modify the warm and cool times in profiles one through five?
No, profiles one to five have fixed periods with no alteration possible. Use profile six if you need to change the warm or cool times to exact requirements. Instruction Manual, p. 11
What's the difference between profile one and profile four on Secure ThermoPlus?
Profile one runs the same schedule every day. Profile four uses different schedules for weekdays (MON-FRI) and weekends (SAT/SUN).
How many preset heating profiles does Secure ThermoPlus PRT1 offer?
Six. Five are fixed and one is adjustable by the installer. Profile one is the default. Instruction Manual, p. 10
Secure ThermoPlus PRT1 compared with other room thermostats
| Specification | Secure ThermoPlus PRT1 | EPH Controls CP4B | EPH Controls HRT |
|---|---|---|---|
| Maximum load | 3(1)Amps (230 V AC) | 8A 230Vac | 8(3)A 230Vac |
| Setpoint range | 5˚C - 30˚C (1˚C Steps) | 5 … 35˚C | 5 … 35˚C |
| Differential | <0.5˚C (At 4˚C/hour) | 0.4˚C | Adjustable from 0.0 – 1.0°C |