HVAC Electrical Heating Thermostat M5.XX Installation Guide
M5.XX Electrical Thermostat
Mounting Manual
supply (e.g. power supply for heating cable) for avoiding the
interference of voltage signal to the heating thermostat. If there is
shielded cable in the extended cable, shielded cable should not be
connected to ground but to terminal 7. It is recommended that the
extended cable and casing should not be shared with others.
International Standard Electronic Heating
Thermostat Characteristics:
ò
ò
ò
Mounted on the surface of the wall indoors
Temperature control range +5/+40℃
Applied in the auto-control system of space
heating
Outer sensor and its resistance:
ò
ò
LED turned on while heating
Satisfying the requirements of safety, energy
saving and comfort.
Temperature(℃)
Resistance(Ω)
22070
5
10
20
30
40
17960
Types Table:
12091
Types
Load
Current
Methods of
Temperature
Measurement
Outside Sensor
8312
Applications
5827
Mounting Location Recommended:
M5.03
The heating thermostat should be mounted on the wall with
air flowing freely around.
Inside Sensor
M5.03I
3A
Outside
&
M5.03D
M5.16
Warning: The mounting location should not be influenced by
other heat source (e.g. sunlight), air flow through doors &
windows or temperature of outer wall.
Heating cable and
other power heat
loads
Inside Sensors
Outside Sensor
M5.16I
16A
Inside Sensor
Outside
&
M5.16D
Inside Sensors
Technique Parameters:
Voltage: 220VAC
Power consumption: 5VA
Temperature control range: 5~40℃
Temperature limit range: 25~55℃
Power save mode temperature: 5℃
Temperature deviation: 0.5K
Ambient temperature: -5~50℃
Degree of protection provided by enclosure: IP20
Outer sensor: length of cable 3m
Specification:
Temperature Set:
The factory default of temperature control range is +5/+40℃.
For convenient adjusting the LED will be turned on while heating.
For the first use, please set the thermostat at the highest
temperature, when the room or floor temperature approaches the
expected, please turn the knob back until the LED is turned off.
One or two days after, user could do fine turning if necessary.
Handling Instruction:
ꢀ on and off
:
off
on
ꢂ
ꢁ
ꢂ
temperature set
5~40
indicator
:
℃
30
40
:
20
LED turned on while
heating.
ꢁ
ꢀ
10
Mounting of Outer Sensor:
℃
Please place the casing under the floor with the outer sensor
in, the terminal of which should be thickened and placed on the
top of the concrete layer. Sensor cable can be extended to 50m
with other cables if necessary. If multi-core cable is used as
extended cable, extra cable core should not be used for power
German OshlandAutomatic Technology Co., Ltd.
Electrical Heating Thermostat
HVAC CONTROLS PRODUCTS
| General | Details |
|---|---|
| Name | HVAC Electrical Heating Thermostat M5.XX Installation Guide |
| Make | HVAC |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.11 MB |

Electrical M5.XX Manual: Questions and Answers
Electrical M5.XX specifications
| Power supply | 220VAC |
| Setpoint range | 5~40℃ |
| Operating temperature | -5~50℃ |
| Power consumption | 5VA |
Can I extend the outer sensor cable on the Electrical M5.XX beyond its standard length?
Yes, the sensor cable can be extended up to 50m using other cables if necessary. If multi-core cable is used as the extension, extra cable cores should not be used for power. Installation Guide, p. 1
What should I do with shielded cable in the extended sensor cable for the Electrical M5.XX?
Connect shielded cable to terminal 7, not to ground. Installation Guide, p. 1
Where should the outer sensor be positioned on the Electrical M5.XX installation?
Place the sensor casing under the floor with the outer sensor inside. The sensor terminal should be positioned on top of the concrete layer. Installation Guide, p. 1