SECURE ThermoPlus PRT1 Programmable Room Thermostat Instruction Manual
Electrical Connections
All necessary electrical connections should now be made.
Flush wiring can enter from the rear through the aperture in the
Backplate. Surface wiring can only enter from beneath the
ThermoPlus and must be securely clamped.
The mains supply terminals are intended to be connected to the
supply by means of fixed wiring.
The ThermoPlus is mains powered and requires a 3Amp fused
spur.The recommended cable sizes are 1.0mm2 or 1.5mm2.
The ThermoPlus is double insulated and does not require an
Earth connection, an Earth connection block is provided on the
Backplate for terminating any cable Earth conductors.
Earth continuity must be maintained and all bare Earth
conductors must be sleeved. Ensure that no conductors are left
protruding outside the central space enclosed by the Backplate.
Commissioning the Thermostat
Ensure all dust and debris has been cleared away from the work
area before removing the ThermoPlus PRT1 from its
packaging.