RECEIVERWIRINGDIAGRAM
ROOMTHERMOSTAT
1
AC
(230V)
ENGLISH
COM
NO
DIGITAL ROOM THERMOSTAT
2
generallife.com.tr
3
4
BATTERY PLACEMENT
5
6
MITRA 250S RF USER MANUAL
HEATING/COOLING UNIT
1
2
3
Battery Indicator
Room Temperature
Set Temperature
Cooling Indicator
- If the Cooling Indicator is blinking, the cooling unit is working.
- If the Cooling Indicator is steady, the cooling unit is not working.
Heating Indicator
- If the Heating Indicator is blinking, the heating unit is working.
- If the Heating Indicator is steady, the heating unit is not working.
ON/OFF and Temperature Setting Button
GENERALSPECIFICATIONS
Warning!
Operations within the heating / cooling unit or the electrical installation
must be carriedout byprofessionally qualified persons.
MITRA 250S RF is a wireless room thermostat. The user can adjust
the room temperature with the required temperature and get more
comfortable and economic heating/cooling.
4
PAIRINGTHEROOMTHERMOSTATANDTHERECEIVER
Primarily press the sync button of receiver for 2 seconds and see blinking
green light of receiver.
5
6
PreciseTemperatureMeasurement
Heating calibration
ON/OFFControl
WirelessConnection
TPIAlgorithm
While yourdeviceis turned off, press and hold thebutton for 3 seconds.
As shown in the picture above, press the screwdriverforward from the space
shown, bend the tabs and separate the front cover. Insert 2 new AAA alkaline
batteries in the battery housing with the correct battery direction. Replace
both batteries at the same time. Then align the front part of your Room
Thermostatto thebackand squeezeittowards theback.
Press thebutton until the“
” menu appears.
Heating/Cooling Modes
RECEIVER
Then turn up thebutton to right or leftway.
1-Manual Operation Button:
Deactivates the Receiver and allows you
If the pairing is successful, the green flashing LED on the receiver will be
constant.
1
2
3
MITRA 250SRF AND EQUIPMENTS
to use heating/cooling unit manually.
2-Pairing Button:
Receiverand Room Thermostathavebeen paired to eachother.
Low Battery Warning: When the “
” icon appears on the screen, it means
Holder
Alkaline
Battery
MITRA 250S RF
Room Thermostat
“low battery warning”. It is recommended to replace the batteries when this
warning appears.
Pairs the Receiver and the Room
ROOMTHERMOSTATTEMPERATURECALIBRATION
Temperature sensors which are used in Room Thermostats are highly
sensitive. You mayneed to calibrate yourRoom Thermostat if youwould like
to get the same temperature values with other thermometers in your living
space.
Thermostat.
Warning: When the product is not used for a long period (more than 15 days),
remove the batteries. Otherwise, malfunctions that may occur would be out of
warranty.
3-Receiver LED Light
4-Receiver Power Cable Input
5-Heating/Cooling Unit Connection
Cable Input
Pleasethrowyourdead batteries into thewastebin forbatteries.
While yourdeviceis turned off, press and hold thebutton for 3 seconds.
Press the button until the “ ” menu appers. In order to see the desired
RECEIVERPLACEMENT
temperature, set the temperature difference by turning the button to right
or left. This valuecan be arranged between“-8oC" and “+8oC".
To save the settings and exit, press the "On/Off" button until the device
turns off.
4
5
The important things to note for the Receiver
placement is avoidingphysical contact between the
Receiver and heating/cooling unit, and protecting it
against materialssuch asliquid, dust etc.
Dowels and
Screws
Receiver
RECEIVERLEDDESCRIPTIONS
Constant Red
Blinking Green
Constant Green
Receiver has power but Receiver and Room
Note:Recommended tempreturecalibration is “0.0oC”.
Thermostat are not paired.
Waiting for pairing signal from the
Room Thermostat.
ROOMTHERMOSTATHEATING/COOLINGMODES
Your Room Thermostat has heating and cooling modes. In order to switch
easilybetweenheating and cooling modes:
Receiver and Room Thermostat are paired.
Heating/cooling unit is not operating.
Operate the heating/cooling unit signal has
reached to the Receiver.
The devices should be placed in order to minimize the damage to the
receivedand transmittedsignals bypayingattentiontothefollowingpoints;
While yourdeviceis turned off, press and hold thebutton for 3 seconds.
The devicesshould not be mounted on metalsurfaces.
The devices should not be installed close to electrical cables and
electronic equipment such ascomputers and televisionunits.
The devices should not be installed near large metal structures or other
building materials using fine metal meshes such as special glass or
special concrete.
3 Short Orange
Blinking
Press thebutton until the“
You can switch between “
” menu appears.
” (heating) and “
” (cooling) modes by
Constant Orange
Heating/cooling unit is operating.
turning thebutton to right or leftin the“
” menu.
TECHNICALDATA
To savethesettingsand exit, press thebutton until thedeviceturns off.
The settings you have made have been saved. Once you turned on your
device, itwill operatewiththechanged settings.
3 Short Green
Blinking
Shut the heating/cooling unit down signal has
reached to the Receiver.
Room Thermostat
Distance between the Room Thermostat and the Receiver should not
exceed20metersor 2 floors.
Blinking Orange
Heating/Cooling unit operates in manual mode.
Dimensions
85mm / 125mm / 24mm
3V DC (2 x AAA alkaline battery)
0.1oC
FACTORY SETTINGS RESET
Operating Current
Temperature Measurement
Accuracy
Receiver must be installed at least 50 cm away from the heating/cooling
unit.
You can reset your Room Thermostat to its default factory settings.
This operation resets the calibration setting, heating/coling modes
and hysteresis settings to factory setting. To reset your Room
Thermostatto factory setting:
Blinking Red
Receiver did not get any signal from the Room
Thermostat for 22 minutes or longer.
Heating/cooling unit has shut down.
(5oC) – (30oC)
RECEIVERSETUP
Operating Temperature Range
Battery Life
First, shut down your heating/cooling unit and your heating/cooling unit's
power sourcewithallelectricalcurrent(fuse, socketetc.)
As shown in the connection diagram, connect one end of the
heating/cooling unit connection cable to the COM and the other to the NO
input of theReceiver.
1 Years (2 x AAA)
(-10oC) – (+50oC)
(-20oC) – (+60oC)
ROOMTHERMOSTATPLACEMENT
While your device is turned off, press and hold the button for 3
seconds.
Operating Temperature
Storage Temperature
Room Thermostat needs to be placed in the room which is used most
frequently. For instance; living room or lounge. Placing the Room
Thermostat in a spot that have air circulation like entrance of a room
or side of window should be avoided. Also anywhere close to
heating/cooling units such as radiator, stove and spots which get
direct sun lights would not be suitable. Room Thermostat needs to be
located above the floor 150 cm height. Few trials may be made to find
themost convenientspot.
Pressthebutton until the“
While in the “ “ menu, turn the button to right or left in order to
select“ “ option and pressthebutton.
” menu appears.
Connect the other ends of the cable -which you connected to the Receiver
to room thermostat connection terminal as shown in your
heating/cooling unit's user manual.
Your devicewillbe turned off and resetto factory settings.
Receiver
You must first connect the Receiver power cable to the Receiver and then
to thefuse to which theheating/cooling unit is connected.
After completing the cable connection process, firstly turn on your fuse
and then yourheating/cooling unit.
TPIROOMTHERMOSTATWORKINGLOGIC
Dimensions
90mm / 90mm / 25mm
230V AC
Your Room Thermostat works with the TPI algorithm. Room
Thermostats using TPI technology predict when the temperature of
your home will rise above or below the set temperature and turn the
heating / cooling unit on and off accordingly. This ensures that your
home stays at the temperature you set without maximum deviations
up and down.
Operation Current
Relay NO Switching Current
min. 20 cm
7A (240VAC – Resistive load)
10A (120VAC – Resistive load)
(-20oC) – (+60oC)
By pressing the Receiver's manual usage button for 2 seconds, youshould
see the Orange Light blinking on the Receiver. In this way, after making
sure that the heating/cooling unit is operating, press the same button
again for 2 seconds and seethattheOrangeLEDturns off.
Set up the Room Thermostat to pair the Receiver with the Room
Thermostat.
Storage Temperature
2
1
3
4
| General | Details |
|---|---|
| Name | GENERAL LIFE MITRA 250S RF Digital Room Thermostat User Manual |
| Make | GENERAL LIFE |
| Language | English |
| Filetype | PDF (Download) |
| File size | 2.18 MB |

GENERAL LIFE HT330S RF Room Thermostat User Manual

GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual

GENERAL LIFE HT250 RF Digital Room Thermostat User Manual

GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual

GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual

GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual

GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual

GENERAL LIFE HT220S RF Digital Room Thermostat User Manual

GENERAL LIFE 270S RF Room Thermostat User Manual

GENERAL LIFE 270 Wireless Room Thermostat User Manual

GENERAL LIFE MITRA 250S RF Digital Room Thermostat User Manual Overview
Summary of Contents
- Page 1: Battery placement is essential for the digital room thermostat. The user can adjust the room temperature for more comfortable heating and cooling. If the cooling indicator is blinking, the cooling unit is working; if steady, it is not. Heating calibration is necessary for accurate temperature control. The receiver and room thermostat must be paired for proper operation. Low battery warning indicates the need for battery replacement. Temperature calibration may be needed for accurate readings. The receiver should be placed away from heating/cooling units and electronic devices. The room thermostat should be located at a height of 150 cm above the floor. The TPI algorithm ensures stable temperature control by predicting temperature changes.
- Page 2: warranty conditions outline the coverage for manufacturing defects for 5 years from the invoice date. tpi technology ensures optimal energy efficiency by measuring and applying the best timings to maintain the desired temperature. devices are delivered in working condition, with on-site commissioning subject to a service fee. repairs under warranty are conducted at the company factory, with transportation costs borne by the customer for on-site services. maintenance of devices is also performed by the company, with travel expenses covered by the customer. the tpi room thermostat adapts to temperature changes and learns how to maintain the desired room temperature efficiently. if the placement of the tpi room thermostats is changed, the learning process restarts and takes about 7 days. malfunctions caused by customer misuse are not covered by the warranty, and all expenses in such cases are the customer's responsibility. the warranty is void if devices are damaged by the customer or if they are used contrary to the user manual. customers can appeal to consumer courts regarding warranty disputes, and the warranty document must be retained throughout the warranty period.