Danfoss REPI Series Digital Thermostat User Manual
Data sheet
REPI Series Digital Thermostat Manual
Description
REPI series thermostats are used to control
room temperature in industrial, commercial and
residential environment via controlling electric
modulating valve with 0-10VDC (4-20mA) control
signal or floating control as well as damper
actuator of VAV system.
Electronic control technology is adopted, with
green backlit LCD display of: working mode
(cooling “ ”, heating “ ”, ventilating “ ”, auto
“
“
” ); fan speed (low “ ”, med “ ”, high “ ”, auto
”); room temperature; setting temperature
etc. push button: On/Off “ ”; mode changeover
”; fan speed choose “ ” and temperature
“
adjustment “ ” and “ ”.
Shell: PC + ABS retardant material.
Function
Detect and Display room temperature
Room temperature setting
Fahrenheit or Celsius degree display
Timing sleep
Control On/Off of cooling and heating
equipment
Selectable single speed or three speed fan
control
Order Guide
Output signal
Model
Fan
(Single/3-speed)
RS485
Network
Input
Control
Remote
Sensor
Floating
Modulation
REPI-2
REPI-2N
REPI-4
Cooling/Heating
Cooling/Heating
Cooling/Heating
Cooling/Heating
REPI-4N
Fan: thermostat with fan functions, can be selected with single speed fan or three speed fan by setting parameter.
Remote Control: input signal can be selected by setting parameter.
Specification
Set temperature range: 0 - 99.5 °C adjustable
Accuracy displayed: 0.1 °C
Accuracy: 0.5 °C
Rated Power: < 1 W
Sensor type: NTC
Output signal: AC 24V×2 (0.5A resistive) ,
0 - 10VDC(5mA) / 4 - 20mA (600Ω)
Relay load: 2A (resistive load), 1A (inductive
load)
Input signal: dry contact (NO)
Dimensions: 86×86×23mm (W×H×D)
Fixing screw width : 60mm (Standard)
Display: LCD
Power: AC 24V 10%, 50Hz/60Hz
© Danfoss | 2022.05
AI097986404620en-010102 | 1
| General | Details |
|---|---|
| Name | Danfoss REPI Series Digital Thermostat User Manual |
| Make | Danfoss |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.24 MB |

Danfoss RET-MD Electronic Intelligent Dial Setting Thermostat Installation Guide
Danfoss VICUQ24M Icon Programmable II Room Thermostat Installation Guide

Danfoss MBC 8000, MBC 8100 Heavy Duty Thermostat Installation Guide

Danfoss UT 72-UT 73 Universal Thermostat Installation Guide

Danfoss ECtemp 530 Electronic Thermostat Installation Guide

Danfoss 014G0251 Eco Radiator Thermostat User Guide

Danfoss 014G0013 Z Wave Radiator Thermostat Installation Guide

Danfoss RET230P Electronic Thermostat Instruction Manual

Danfoss TP7000 Range Electronic 7 Day Programmable Room Thermostat Installation Guide

Danfoss RET1000 Series Electronic Thermostat User Guide

Danfoss REPI Manual: Questions and Answers
Danfoss REPI specifications
| Power supply | AC 24V 10%, 50Hz/60Hz |
| Maximum load | 2A (resistive load), 1A |
| Accuracy | 0.5 °C |
| Sensor | NTC |
| Dimensions | 86×86×23mm (W×H×D) |
Can I use the Danfoss REPI thermostat to control both heating and cooling equipment?
Yes. The Danfoss REPI can control room temperature via electric modulating valves with 0-10VDC or 4-20mA control signals, or floating control and damper actuators in both heating and cooling modes. User Manual, p. 1
What do the buttons on the Danfoss REPI thermostat control?
One button turns the unit on and off. Others adjust setpoint temperature, change working mode, select fan speed, and access the parameter menu. User Manual, p. 2
How does auto fan speed differ from fixed fan speed on Danfoss REPI?
Auto speed adjusts fan output based on temperature difference from setpoint. Fixed speeds run at one constant level regardless of temperature. User Manual, p. 2
How do I set the sleep timer?
Press the designated button for 3 seconds until the sleep display appears, then adjust the countdown time up to 48 hours and confirm.
- Press the sleep button for 3 seconds until the sleep display shows.
- Use the adjustment buttons to set desired sleep time up to 48 hours.
- Thermostat returns to working status after 5 seconds with the sleep icon flashing. User Manual, p. 2
Danfoss REPI compared with other Danfoss thermostats
| Specification | Danfoss REPI | Danfoss 220V Electronic Intelligent Timer Thermostat | Danfoss ECtemp 132 | Danfoss ECtemp Next Plus |
|---|---|---|---|---|
| Power supply | AC 24V 10%, 50Hz/60Hz | 220-240 V~, 50/60 Hz | 220-240 V~, 50 Hz | 85-250V~, 50/60 Hz |
| Maximum load | 2A (resistive load), 1A | Max. 16 A / 3680 W @ 230 V | Max 16 A / 3680 W @ 230 V | Max. 16 A / 3680 W @ 230 V |
| Sensor | NTC | NTC 6.8 k at 25°C | NTC 15 kOhm at 25 °C | Floor Sensor NTC 15 kΩ |
| Dimensions | 86×86×23mm (W×H×D) | 85 x 85 x 20-24 mm | 82 x 82 x 36 mm | 86 x 86 x 16/40.5 mm |