REPI Series Digital Thermostat Manual  
Operations  
Sleep: Thermostat will get into sleep function  
after programming.The set Temperature should  
to be.  
On/Off: Press “ ” buttons to turn on;  
press “ ” again to turn off.  
Setpoint: With thermostat on, press “ ” to  
reduce the setpoint, press “ ” to increase the  
setpoint, the setpoint step is  
To set: Press “ ” button for 3 seconds till  
” display, there’s a number of count down  
in the center of LCD, Use “ ” or “ ” to adjust  
the desired sleep time: the max. = 48 hours;  
thermostat will return to the working status after  
5 seconds, “ ” is flashing to start counting down.  
The setpoint should be replaced by the sleep  
setpoint.  
To quit: When thermostat get into Sleep  
function, “ ” will flash, press “ ” or “ ” to quit.  
Keypad lock: press “ ” and “ ” for 10  
seconds till to “ ” display to activate, under this  
function, any keypad is locked.  
0.5 °C, the setpoint will be confirmed  
automatically after 5 seconds, and then return to  
dispay status, press “ ” or “ ” to check setpoint.  
Mode: With thermostat on, press “ ” to  
change the working mode – Cooling “ ”,  
Heating “ ”, Vent “ “, Auto “  
( Auto is available REPI-4/ REPI-4N).  
Fan Speed: With thermostat on, press “ ” to  
select the desired speed – low speed “ ”, Med  
speed “ ”, High speed “ ”, auto “ ”. If single  
speed fan available, there’s only med speed “ ”.  
Under auto speed fan, the fan speed will be  
changed automatically as below: in low speed  
when room temperature  
is 1 °C difference with setpoint;in med speed  
when room temperature is 2 °C difference with  
setpoint; in High speed when  
Press “ ” and “ ” for 10 seconds till “  
disappear to quit the function.  
Set Parameters: With thermostat off, press  
” for 10 seconds to enter menu to set the  
parameters.  
room temperature is 3 °C difference with  
setpoint.  
Parameter table  
Parameter Description  
Default  
Range  
0 - 2  
Step  
1
2
Power on status (0: Off; 1: On; 2: Hold)  
Fan speed (0: Single Speed; 1: Three Speed)  
Fan mode (DA; DB)  
2
1
0 - 1  
3
0
4
Sensor selection (0: Internal; 1: Remote)  
Temperature format (0: Celsius; 1: Fahrenheit)  
Temperature calibration  
1
0 - 1  
0 - 1  
5
0
0
0.1  
0.1  
0.5  
0.5  
0.5  
0.5  
0.5  
1
6
-20.0 - +20.0  
0 - 99.5  
0 - 99.5  
0 - 10  
7
Minimum setpoint  
5 °C/41 °F  
35 °C/96  
2
8
Maximum setpoint  
9
Dead band (REPI-4)  
10  
11  
12  
Heating & Auto sleep setpoint  
Cooling sleep setpoint  
7 °C/45 °F  
28 °C/82  
1
0 - 99.5  
0 - 99.5  
1 - 32  
Comms# (REPI-2N;REPI-4N)  
Input Signal Mode 0: Invalid  
1: Changeover(REPI-2)  
2: thermostat will be sleep without input signal  
3: thermostat will be Off without input signal  
13  
0
0 - 3  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
Heating reset time  
90 sec.  
90 sec.  
0
10 - 300 sec.  
10 - 300 sec.  
0 - 1  
10 sec.  
10 sec.  
Cooling reset time  
Ports mode (0: Modulation & Floating; 1: On/Off)  
Valve status as turn off (0: Close; 1:Hold; 2: Open )  
Port1 Modulation direction (0:10V Open; 1:10V Close)  
Port1 Modulation minimum signal  
Port1 Modulation proportional  
0
0 - 2  
0
0 - 1  
0Bit  
2
0-128Bit(5V/10mA) 0.04V/Bit(0.08mA/Bit)  
1 - 20  
0 - 1  
0.5  
Port2 Modulation direction (0:10V Open; 1:10V Close)  
Port2 Modulation minimum Signal  
Port2 Modulation proportional  
0
0 Bit  
2
0-128Bit(5V/10mA) 0.04V/Bit(0.08mA/Bit)  
1 - 20  
0.5  
Port1 Floating minimum time  
1 sec.  
30 sec.  
1 sec.  
30 sec.  
1 - 9 sec.  
1 sec.  
10 sec.  
1 sec.  
10 sec.  
Port1 Floating maximum time  
10 - 300 sec.  
1-9 sec.  
Port1 Floating minimum time  
Port1 Floating maximum time  
10 - 300 sec.  
Disable / Enable bypass PID control  
(0: Disable; 1: Enable)  
28  
29  
0
0-1  
Override output value when bypass PID control  
Display output value when enable PID control  
0 - 255  
2 | AI097986404620en-010102  
© Danfoss | 2022.05  
GeneralDetails
NameDanfoss REPI Series Digital Thermostat User Manual
MakeDanfoss
LanguageEnglish
FiletypePDF (Download)
File size0.24 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
Danfoss RET-MD Electronic Intelligent Dial Setting Thermostat Installation Guide
Danfoss RET-MD Electronic Intelligent Dial Setting Thermostat Installation Guide
Danfoss VICUQ24M Icon Programmable II Room Thermostat Installation Guide
Danfoss VICUQ24M Icon Programmable II Room Thermostat Installation Guide
Danfoss MBC 8000, MBC 8100 Heavy Duty Thermostat Installation Guide
Danfoss MBC 8000, MBC 8100 Heavy Duty Thermostat Installation Guide
Danfoss UT 72-UT 73 Universal Thermostat Installation Guide
Danfoss UT 72-UT 73 Universal Thermostat Installation Guide
Danfoss ECtemp 530 Electronic Thermostat Installation Guide
Danfoss ECtemp 530 Electronic Thermostat Installation Guide
Danfoss 014G0251 Eco Radiator Thermostat User Guide
Danfoss 014G0251 Eco Radiator Thermostat User Guide
Danfoss 014G0013 Z Wave Radiator Thermostat Installation Guide
Danfoss 014G0013 Z Wave Radiator Thermostat Installation Guide
Danfoss RET230P Electronic Thermostat Instruction Manual
Danfoss RET230P Electronic Thermostat Instruction Manual
Danfoss TP7000 Range Electronic 7 Day Programmable Room Thermostat Installation Guide
Danfoss TP7000 Range Electronic 7 Day Programmable Room Thermostat Installation Guide
Danfoss RET1000 Series Electronic Thermostat User Guide
Danfoss RET1000 Series Electronic Thermostat User Guide

Danfoss REPI Series Digital Thermostat User Manual