Danfoss 220V Electronic Intelligent Timer Thermostat Installation Guide
| General | Details |
|---|---|
| Name | Danfoss 220V Electronic Intelligent Timer Thermostat Installation Guide |
| Make | Danfoss |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.74 MB |

Danfoss RET-MD Electronic Intelligent Dial Setting Thermostat Installation Guide
Danfoss VICUQ24M Icon Programmable II Room Thermostat Installation Guide

Danfoss MBC 8000, MBC 8100 Heavy Duty Thermostat Installation Guide

Danfoss UT 72-UT 73 Universal Thermostat Installation Guide

Danfoss ECtemp 530 Electronic Thermostat Installation Guide

Danfoss 014G0251 Eco Radiator Thermostat User Guide

Danfoss 014G0013 Z Wave Radiator Thermostat Installation Guide

Danfoss RET230P Electronic Thermostat Instruction Manual

Danfoss TP7000 Range Electronic 7 Day Programmable Room Thermostat Installation Guide

Danfoss RET1000 Series Electronic Thermostat User Guide

Danfoss 220V Electronic Intelligent Timer Thermostat Manual: Questions and Answers
Danfoss 220V Electronic Intelligent Timer Thermostat specifications
| Power supply | 220-240 V~, 50/60 Hz |
| Maximum load | Max. 16 A / 3680 W @ 230 V |
| Floor temperature limit | 5-45°C |
| Setpoint range | Room temperature: 5-35°C |
| Sensor | NTC 6.8 k at 25°C |
| Operating temperature | 0° to +30°C |
| Storage temperature | -20°C to +65°C |
| Dimensions | 85 x 85 x 20-24 mm |
| Weight | 103 g |
| Power consumption | Max. 0.40 W |
Can I set the maximum floor temperature higher than 35°C when using a wooden floor?
No. With a wooden floor or similar material, never set maximum floor temperature above 35°C, even if using a floor sensor. This reduces the risk of overheating the floor. Installation Guide, p. 5
What is the maximum resistive load the Danfoss 220V relay can handle?
16 A at 230 V, or 3680 W. Installation Guide, p. 3
How do I enable the timer function on a Danfoss 220V Electronic Intelligent Timer Thermostat?
During setup wizard at step 12, use the arrows to select whether timer activation is on or off, then press to confirm. Installation Guide, p. 13
What does the forecast feature do on a Danfoss 220V Electronic Intelligent Timer Thermostat?
Forecast starts heating before your comfort period begins so the room reaches your target temperature at the scheduled time, and optimises when heating stops when switching to economy mode. Installation Guide, p. 13
Danfoss 220V Electronic Intelligent Timer Thermostat compared with other Danfoss thermostats
| Specification | Danfoss 220V Electronic Intelligent Timer Thermostat | Danfoss ECtemp Next Plus | Danfoss DEVIreg 316 | Danfoss DEVIreg 530 |
|---|---|---|---|---|
| Power supply | 220-240 V~, 50/60 Hz | 85-250V~, 50/60 Hz | 220 - 240V~, 50Hz | 220-240V~, 50Hz |
| Setpoint range | Room temperature: 5-35°C | Room temperature: 5-35°C | -10 ° to +50 °C | 5-45°C with floor |
| Sensor | NTC 6.8 k at 25°C | Floor Sensor NTC 15 kΩ | NTC 15 kOhm at 25 °C | NTC 15kOhm at 25°C |
| Operating temperature | 0° to +30°C | -10°C to +60°C | -10 °C to +45 °C | -10 to +30°C |
| Storage temperature | -20°C to +65°C | -20°C to +65°C | -20 °C to +65 °C | -20 to +65°C |
| Dimensions | 85 x 85 x 20-24 mm | 86 x 86 x 16/40.5 mm | 86 x 36 x 58 mm | 85 x 85 x 36 mm |
| Weight | 103 g | 103 g | 180 g | 90 g |
| Power consumption | Max. 0.40 W | 0,4 W | Max 0.25W | Max 0.25W |