Home > Lennox > LENNOX S40 Smart Thermostat User Guide

LENNOX S40 Smart Thermostat User Guide

Table 2. Home and Status Screens Icon Descriptions  
Purpose  
Function or  
Screen Text  
Icon  
Defrosting  
The heat pump system is defrosting the outdoor unit coil. Not available for non-heat pump systems.  
All heat pumps operating in northern climates below 35°F (1.6°C) normally need a supplemental heating source. Usually  
it is in the form of electric heating provided by the indoor unit. Other sources could be gas, oil, or hot-water back-up  
systems as well. The supplemental heat is also referred to as “second-stage” or “back-up” heating, with “first-stage” being  
the heat pump only. Emergency heat is supplemental heat (2nd stage) is used solely, without the use of a heat pump (1st  
stage heat). Not available for non-heat pump systems.  
Emergency  
Heat  
If outdoor temperature is above the high balance point, only the heat pump will operate - default 50°F (10°C) high. If  
outdoor temperature is below the low balance point, only auxiliary heating will operate - default 25°F (-4.0°C) low. If  
outdoor temperature is in-between the high and low balance point, both the heat pump and auxiliary heat sources can  
operate. Not available for non-heat pump systems.  
Auxiliary Heat  
Will start soon  
A five minute safety delay prevents the compressor from operating too soon after shut-down to allow internal pressures to  
equalize.  
This indicates that either the outdoor temperature is above or below the balance point temperature settings. The low  
balance point setting prevents heat pump heating below the set point and back up heat will be used. Typically the default  
is 25°F (-4.0°C), but that setting can be adjusted by the dealer. At 25°F (-4.0°C) or below for example, only auxiliary  
heating (electric or gas) is used. If the high balance point is set to 50°F (10°C) for example, which is also adjustable by  
the dealer, then auxiliary heat will not be allowed. Only heat pump heating will be used. Anytime the outdoor temperature  
is below or above the balance point temperature settings, the ambient lockout notice will appear on the Home screen.  
Ambient  
lockout  
Fan is running  
Fan set to ON. Fan is NOT following the schedule and runs continuously until it is changed from the selected mode.  
Fan in auto  
mode is active  
Fan set to Auto. Fan will follow the fan setting in the selected schedule.  
Fan in circulate  
mode is active  
Fan set to Circulate. Fan is following schedule and cycles during periods of equipment inactivity. Circulate run time is  
dependent on user settings.  
20  
GeneralDetails
NameLENNOX S40 Smart Thermostat User Guide
MakeLennox
LanguageEnglish
FiletypePDF (Download)
File size1.3 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
LENNOX L40 Smart Thermostat Owner’s Manual
LENNOX L40 Smart Thermostat Owner’s Manual
LENNOX EL18KCV Smart Wi-Fi Communicating Thermostat User Manual
LENNOX EL18KCV Smart Wi-Fi Communicating Thermostat User Manual

LENNOX S40 Smart Thermostat User Guide