LENNOX EL18KCV Smart Wi-Fi Communicating Thermostat User Manual
A I R C O N D I T I O N E R S
EL18KCV
ELITE® SERIES
Variable Capacity | Precise Comfort® Technology | Environ™ Coil | R-454B | 60Hz
R E S I D E N T I A L
P R O D U CT S P E C I F I C AT I O N S ( E H B )
2 to 5 Tons
SEER2 up to 19.5
Cooling Capacity | 22,000 to 58,500 Btuh
2025 COMPLIANT
REFRIGERANT
S40 Smart Wi-Fi
Communicating Thermostat
(not furnished - ordered separately)
MODEL NUMBER IDENTIFICATION
EL 18 K C V - 036 - 230 A 01
Product Tier
Revision Level
EL = Elite® Series
Nominal SEER2
18 = 18.0 to 18.9
Ratings Revision Level
Refrigerant Type
Voltage
230 = 208/230V-1 phase-60Hz
K = R-454B
Unit Type
C = Air Conditioner (Condenser)
Nominal Cooling Capacity
024 = 2 tons
036 = 3 tons
Cooling Stages
V = Variable Capacity Compressor
048 = 4 tons
060 = 5 tons
Form Number 211055 | January 2025
Supersedes all previous versions
| General | Details |
|---|---|
| Name | LENNOX EL18KCV Smart Wi-Fi Communicating Thermostat User Manual |
| Make | Lennox |
| Language | English |
| Filetype | PDF (Download) |
| File size | 2.82 MB |

LENNOX L40 Smart Thermostat Owner’s Manual

LENNOX S40 Smart Thermostat User Guide

Lennox EL18KCV Manual: Questions and Answers
What do the red and green LEDs on the Lennox EL18KCV DC Inverter Control indicate?
They indicate inverter operating status and aid in troubleshooting. User Manual, p. 5
Can the Lennox EL18KCV operate in temperatures below freezing?
Yes, it can operate down to 0°F outdoor air temperature, though a freezestat is recommended for extra protection during low ambient operation. User Manual, p. 5
What does the seven-segment display on the Lennox EL18KCV show?
Information about outdoor unit type and capacity, plus alerts for common fault conditions (electrical and mechanical). User Manual, p. 5
How do I check the refrigerant charge on a Lennox EL18KCV?
Refer to the unit-mounted charging sticker to determine the correct amount of charge required. User Manual, p. 3
What is the compressor warranty period for Lennox EL18KCV in residential use?
Limited ten years in residential installations. User Manual, p. 3
How will I know if the system has lost refrigerant charge?
The low pressure transducer shuts off the unit if suction pressure falls below its setting, providing loss of charge protection. User Manual, p. 3