EXPANDED SOUND DATA  
Octave Band Sound Power Levels dBA, re 10-12 Watts  
Center Frequency - HZ  
1 Sound  
² Estimated Sound Pressure Level at  
Rating Distance From Unit (dBA at distance in ft.)  
Number  
(dBA)  
Size  
125  
250  
500  
1000  
2000  
4000  
8000  
3
5
10  
15  
50  
024 Min.  
024 Max.  
036 Min.  
036 Max.  
048 Min.  
048 Max.  
060 Min.  
060 Max.  
54  
53.5  
62  
58.5  
58.5  
63  
66.5  
62.5  
68  
63.5  
61  
62  
60.5  
56.5  
66.5  
53  
56.5  
56  
70  
63  
60  
69  
59  
69  
65  
72  
60  
58  
55  
64  
54  
64  
60  
67  
55  
52  
49  
58  
48  
58  
54  
61  
49  
49  
46  
55  
45  
55  
51  
58  
46  
38  
35  
44  
34  
44  
40  
47  
35  
59  
67  
71  
70.5  
58  
61  
76  
53  
56  
60.5  
70.5  
67.5  
72  
5
9
54  
66  
56  
65  
69.5  
67.5  
73.5  
59  
67.5  
63.5  
70.5  
60.5  
67.5  
61.5  
71  
57  
76  
56.5  
59  
62  
58  
72  
64.5  
58  
57.5  
51  
79  
52.5  
63  
56.5  
67  
NOTE - The octave sound power data does not include tonal correction.  
1 Tested according to AHRI Standard 270-2008 test conditions. Sound rating Number is the overall A-Weighted Sound Power Level, (LWA), dB (100 Hz to 10,000 Hz).  
2 Estimated sound pressure level at distance based on AHRI Standard 275-2010 method for equipment located on the ground, roof, or on side of building wall with no  
adjacent reflective surface within 9.8 feet. Sound pressure levels will increase based on changes to assumptions. For other applications, refer to AHRI Standard 275.  
FIELD WIRING  
A - Two Wire Power  
B - Two Wire Power (see Electrical Data)  
C - Lennox® Communicating Thermostat:  
- Four Wire, 18AWG (RSBus)  
DISCONNECT  
SWITCH  
(By Others)  
DISCONNECT  
SWITCH  
(By Others)  
THERMOSTAT  
(Required)  
C - Conventional Thermostat:  
A
- Four Wire Low Voltage, 18AWG  
B
D
D - Lennox® Communicating Thermostat:  
- Four Wire, 18 to 22AWG (RSGBus) standard thermostat  
cable for terminals (R, C, I+, I-).  
C
D - Conventional Thermostat:  
LENNOX  
AIR  
CONDITIONER  
LENNOX  
HEATING UNIT  
OR  
AIR HANDLER  
UNIT  
- Six Wire Low Voltage, 18AWG  
NOTE - All wiring must conform to NEC or CEC and local electrical  
codes.  
NOTE - Refer to the S40 Installation Instructions for optional wir-  
ing connections for communicating thermostats.  
NOTE - Field wiring not furnished.  
INSTALLATION CLEARANCES  
See NOTES  
NOTES:  
• Service Clearance − 30 in. (762 mm) on one of the sides  
adjacent to the Control Box.  
• One of other three sides must be 36 in. (914 mm).  
• One of the two remaining sides may be 12 in. (305 mm).  
• The remaining side may be 6 in. (152 mm).  
See  
NOTES  
See  
NOTES  
• 48 in. (1219 mm) clearance required on top of unit  
• 24 in. (610 mm) required between two units  
Control  
Box  
See NOTES  
EL18KCV | 2 to 5 Ton Air Conditioner | Page 9  
GeneralDetails
NameLENNOX EL18KCV Smart Wi-Fi Communicating Thermostat User Manual
MakeLennox
LanguageEnglish
FiletypePDF (Download)
File size2.82 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
LENNOX L40 Smart Thermostat Owner’s Manual
LENNOX L40 Smart Thermostat Owner’s Manual
LENNOX S40 Smart Thermostat User Guide
LENNOX S40 Smart Thermostat User Guide

LENNOX EL18KCV Smart Wi-Fi Communicating Thermostat User Manual