Home > SunTouch > SunTouch 500950-SB CommandPlus Touchscreen Programmable Smart Thermostat Instruction Manual
SunTouch 500950-SB CommandPlus Touchscreen Programmable Smart Thermostat Instruction Manual
television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one of the
following measures:
The following cautions must be observed:
CommandPlus Wiring
Before connecting the wires to the back of the thermostat, detach
the display front from the base.
SunStat Sensor Installation
• The SunStat sensor can be installed with or without electrical
conduit depending on code requirements. Conduit is
recommended for added protection against nails and screws.
SunStat® CommandPlus™
ALWAYS install the floor sensor included with the thermostat.
NEVER put the system into full operation until the tile or flooring installer
verifies all cement materials are fully cured (typically two to four weeks
after installation).
• Reorient or relocate the receiving antenna.
While holding the base section in one hand, with the other pull
gently up holding the sides of the thermostat towards the bottom
(near RESET button), pivoting away from the base.
• Increase the separation between the equipment and receiver.
• Consult the dealer or an experienced radio/TV technician for help.
• Do not place the sensor in the same conduit as the power
leads to avoid possible interference. Open a separate knock-
out in the bottom of the thermostat box. Feed the sensor (and
conduit, if used) through the knock-out, down through the
cut-out in the bottom plate, and out into the floor where the
heating cable will be installed.
Installation and
Operation Manual
ALWAYS use insulated copper wires rated for 90°C (194°F) and 600 V
minimum. Do not use aluminum.
Remove back cover plate to expose the power terminals.
Box Contents
• SunStat® CommandPlus Wi-Fi thermostat
ALWAYS wire all circuits as Class 1, electric light & power circuits.
Power Wiring
• Connect the ground wire from the power supply to the
ground wire from the floor heating power lead
Features:
• Floor or air-sensing
temperature control
• Remote access via
Home mobile app
ALWAYS mount the thermostat to a grounded electrical box.
or sensor
• If the sensor wire needs to be secured to the wall stud, wait
until after the wire or mat and sensor are completely installed
on the floor.
ALWAYS seek help if a problem arises. If ever in doubt about the correct
installation procedure, or if the product appears to be damaged, the
factory must be contacted before proceeding with the installation.
rewdriver
• If the electrical box is metal, use a short length of wire to
connect the ground wires to the bonding screw
tallation manual
chine screws (2), 6-32
• At the sensor location, measure at least 1' into the heated
area. Mark the spot where the sensor will be attached to the
floor. Be sure to place the sensor exactly between two of the
heating wires. Ensure the sensor wire does not cross over any
heating wires.
• Connect the floor heating power lead conductors to the
LOAD 1 and LOAD 2 terminals
• Large touchscreen d
• Easy-to-use schedu
• Portrait display
s Needed
• For 120 VAC connections, connect the power supply
black (L) wire to the L terminal and the white (N) wire to
the N terminal
To prevent the risk of personal injury and/or death,
make sure power is not applied to the product until
it is fully installed and ready for final testing. All work
must be done with power turned off to the circuit
being worked on.
ctrical box (must be UL listed and proper size)
Portrait: vertical 1-gang box
• Do not locate the sensor outside the heating area or in a gap
between heating wires that is wider than the rest of the floor.
Do not locate the sensor where direct sun, hot-water piping,
heat duct, or lighting below will cause inaccurate temperature
reading. Do not locate the sensor where an insulating item
such as a rug is likely to be placed.
• Guided setup
Landscape: square 2-gang box/plastic 1-gang mud ring
nduit, flexible or rigid (if required, must be UL listed and
oper size)
• For 240 VAC connections, connect one of the power supply
wires to the L1 terminal and the other to the L2 terminal
• Comprehensive help
screens
• Replace back cover plate to cover your connections.
To reduce the risk of electric shock, do not connect to a circuit
operating at more than 150 V to ground.
• Energy use monitori
• Voltage-level sensin
• Floor Sensor Include
ctrical wiring cable (UL listed)
Minimum 14 AWG to 12 A
12 AWG to 15 A
Power Supply
Pull power supply wiring to the control location.
• Leave about 6 to 8" (15 to 20 cm) of wire for connections.
• To make sure the sensor tip does not create a high spot in the
floor, it may be necessary to chisel a channel into the floor and
lay the sensor tip into the channel. Hot glue the tip into place.
• Wired connection to
SunStat® R4 Relay
(sold separately)
il plate
t glue gun and hot glue
• Do not cut the sensor wire or remove the black cable
protector. Strip the wire ends to 1⁄8" long.
• This wiring should be size 12 or 14 AWG, in compliance with
local code requirements.
• 3 Year warranty
Location
• Indoor location only
• A qualified person should run a dedicated circuit from
the main circuit breaker panel to the control location. If a
dedicated circuit is not possible, it is acceptable to tap into
an existing circuit. However, there must be enough capacity
to handle the load (amps) of the floor heating system being
installed, and any appliance likely to be used on the circuit
such as a hair dryer or vacuum cleaner.
SunTouch® Model# 500950-SB/BB/WB/PB
• Do not install where there is a draft, direct sun, hot-water
piping, ducting, or other cause for inaccurate temperature
readings
Specifications:
Power supply
120/240 VAC, 60 Hz, 3 W
15 A, resistive
• Do not install where there is electrical interference from
equipment, appliances, or other sources
Maximum load
Maximum power
1800 W at 120 VAC
3600 W at 240 VAC
Class A (5 mA trip)
• Install away from all water sources such as sinks and at least
4 ft (1.2 m) away from showers and bathtubs
• Avoid circuits that have ballasted lighting, motors,
exhaust fans, or hot tub pumps to reduce the likelihood
of interference.
• Consider easy access for wiring, viewing, and adjusting
GFCI
Dimensions
4.73" H x 3.11" W x 1.9" D (120 x 79 x 48 mm)
0.620" D (16 mm) from wall
• Install at a suitable height, normally about 4-1/2 ft to 5 ft
(1.4 m to 1.5 m) from the floor
• The circuit breaker should be rated 20 amps for total circuit
loads up to 15 amps. A 15-amp circuit breaker may be used
for total circuit loads up to 12 amps.
Low Voltage Wiring
Type 1 or Type 2 action
Sensor, R4 Relay, and Home Automation connections are made
to the terminal block by inserting the wires into the openings and
tightening the screws. Three holes are provided for wire access
from the back. Wires must be routed in the channel to the right of
the terminal block so that the display front can be re-attached. Any
low voltage wiring that passes through the inside of the electrical
box must be rated at least 90°C 300 V.
and additional features Type 2.B
Rated impulse voltage 2500 V
Control pollution degree PD2
Important Safety Information
• A GFCI (ground-fault circuit interrupter) or AFCI (arc-fault
circuit interrupter) type circuit breaker may be used, but is not
necessary.
Floor Heating Mat or Cable Power Lead Installation
• The shielded power lead can be installed with or without
electrical conduit (recommended for added protection against
nails or screws), depending on code requirements.
This is a safety-alert symbol. The safety-alert symbol
is shown alone or used with a signal word (DANGER,
WARNING, or CAUTION), a pictorial and/or a safety
message to identify hazards.
Approvals
UL 943, UL/CSA 60730, UL 991
Ambient conditions
Floor Sensor
32°F to 86°F (0°C to 30°C), < 90% RH non-condensing
Thermistor, 10kΩ NTC type, 300 V jacketed cable, 15 ft
• Remove one of the knock-outs in the electrical box to route
the power lead. If electrical conduit is not required by code,
install a wire collar to secure the power leads where they enter
the box. If conduit is required by code, install 1⁄2" (minimum)
conduit from the bottom plate up to the electrical box. For
multiple power leads (multiple cables), install 3⁄4" conduit.
Make sure 120 VAC is supplied to 120 VAC cables and 240 VAC
is supplied to 240 VAC mat or wire. Otherwise, dangerous over-
heating and a fire hazard could result. Do not exceed 15-amps
on this control.
When you see this symbol alone or with a signal word on your
equipment or in this manual, be alert to the potential for death or
serious personal injury.
• Sensor—connect to the SENSOR terminals, not polarity
sensitive
• R4 Relay—connect to RELAY and COM terminals, matching
connections on the R4 Relay
Read this manual BEFORE using this equipment.
Bottom Plate Work
• Home Automation—connect to AWAY and COM terminals,
refer to home automation control instructions
• Secure a steel nail plate over the cutout in the bottom plate to
protect the wires against baseboard nails later.
Failure to read and follow all safety and
use information can result in death, serious
personal injury, property damage, or damage to
the equipment.
This pictorial alerts you to electricity,
electrocution, and shock hazards.
• Drill or chisel holes at the bottom plate as indicated. One hole
is for routing the power lead conduit and the other is for the
thermostat sensor. These holes should be directly below the
electrical box(es).
SunStat Relay Rough-in Wiring
SunStat® R4 Relays are used when more than 15 A must be controlled
by one CommandPlus thermostat. The CommandPlus can connect
wirelessly to the R4 Relay (see Operation > Wireless Pairing). If a
wired connection is desired, follow these steps.
This symbol identifies hazards which, if not
avoided, could result in death or serious injury.
Keep this manual for future reference.
Make sure the wire connections are secure by gently tugging
on them. Otherwise, arcing could occur, causing dangerous
overheating and a possible fire hazard.
Wire
The antenna used for this radio must be properly installed and maintained
and must provide a separation distance of at least 7.9 inches (20 cm) from
all persons.
Power lead
clip
This symbol identifies practices, actions, or
failure to act, which could result in property
damage or damage to the equipment.
• Pull 18 AWG to 24 AWG 2-conductor wire from the R4 Relay
location to the CommandPlus location
conduit
Finish CommandPlus Installation
• Ensure all connections are secure
Sensor wire
This device complies with Part 15 of the FCC Rules and with Industry Canada
license-exempt RSS standard(s). Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this
device must accept any interference received, including interference that
may cause undesired operation.
• The wire may be up to 100 ft (30 m) long
• Strip the wire ends to 1⁄8" long
• Carefully press the wires into the electrical box
• Do not use the thermostat to push the wires
Installation
Power
lead
• Refer to the R4 Relay manual for additional details
• Secure the thermostat base to the electrical box with the
screws included
Home Automation System Rough-in Wiring
A short or 24 VAC applied between the AWAY and COM terminals
will switch the thermostat into ‘Away’ mode.
Installation must be performed by qualified persons, in accordance
with local codes, ANSI/NFPA 70 (NEC Article 424) and CEC Part 1
Section 62 where applicable. Prior to installation, please consult
the local codes in order to understand what is acceptable. To the
extent this information is not consistent with local codes, the local
codes should be followed. Regardless, electrical wiring is required
from a circuit breaker or other electrical circuit to the control. It
is recommended that an electrician perform these installation
steps. Please be aware local codes may require this product to
be installed by an electrician.
Changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
Sensor wire
• Do not overtighten
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates uses and can radiate
radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
• Re-attach the display front
- Line up the top edge with the base
• Pull 18 AWG to 24 AWG 2-conductor wire from the home
automation location to the CommandPlus location
• Strip the wire ends to 1⁄8" long
For retrofit installations, cut
out drywall and chisel out the
bottom plate to route wires
to control.
-
Rotate the bottom towards the base and snap it into position
See over for operation details
| General | Details |
|---|---|
| Name | SunTouch 500950-SB CommandPlus Touchscreen Programmable Smart Thermostat Instruction Manual |
| Make | SunTouch |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.31 MB |

SunTouch 113901 SunStat ConnectPlus Thermostat User Manual

SUNTOUCH SunStat 1140-01 R4 Relay Thermostat User Manual

SunTouch SunStat CommandPlus Programmable Thermostat Instruction Manual

SunTouch 500950-SB CommandPlus Touchscreen Programmable Smart Thermostat Instruction Manual Overview
Summary of Contents
- Page 1: television reception can be determined by turning the equipment off and on. The user is encouraged to try to correct the interference by various measures. Before connecting the wires to the back of the thermostat, detach the display front from the base. The SunStat sensor can be installed with or without electrical conduit depending on code requirements. Always install the floor sensor included with the thermostat. Never put the system into full operation until the tile or flooring installer verifies all cement materials are fully cured. Always use insulated copper wires rated for 90°C and 600 V minimum. Always wire all circuits as Class 1, electric light & power circuits. Do not place the sensor in the same conduit as the power leads to avoid possible interference. A qualified person should run a dedicated circuit from the main circuit breaker panel to the control location. Read this manual before using this equipment.
- Page 2: Floor sensor error indicates the floor sensor is disconnected or needs to be replaced. Make sure the mortar has had time to fully cure before operating the system for more than a brief test. Programming may be lost—verify all settings. The default schedule has a weekdays program and a weekends program. To create a new schedule, select Change Days. Smart Start will begin heating the floor early to meet the scheduled temperature on time. Press the TEST button on the GFCI monthly to verify that it is operational. If the GFCI trips during normal operation, press the RESET button to resume operation. It is strongly recommended that a qualified, licensed electrician install the heating cables and related electrical components. Warm Weather Shut Down saves energy by turning off the heating system when the outdoor temperature is above the setting.