Home > GENERAL LIFE > GENERAL LIFE FH104 Underfloor Heating Thermostat User Manual
GENERAL LIFE FH104 Underfloor Heating Thermostat User Manual
ROOM THERMOSTAT PLACEMENT
WIRING DIAGRAM FOR ACTUATOR
ENGLISH
Place your Room Thermostat in a room you use frequently in your
living space. For example; like the hall or living room of your home.
Avoid installing the Room Thermostat in places where there is a lot of
air circulation, such as at the doorway or by the window. Also, do not
place it close to heating units (heater core, fireplace, etc.) and in direct
sunlight. We recommend that the room thermostat is placed at a
height of 150cmfrom thefloor.
N
L
L1
N1
UNDERFLOOR HEATING THERMOSTAT
generallife.com.tr
FH104 USER MANUAL
min. 20 cm
GENERAL SPECIFICATIONS
FH104 is
UNDERFLOOR HEATING THERMOSTAT
a
floor heating room thermostat. User provides more
comfortable and affordable heating by setting needed room
temperature.
SensitiveTemperatureMeasurement
Wired Connection
ACTUATOR
ON/ OFFControl
ROOM THERMOSTAT WORKING PRINCIPLE
FH104
USER MANUAL
As soon as you energize your Room Thermostat, it will start working.
Your Room Thermostat measures the temperature of the
environment it is in every 5 seconds. If the ambient temperature rises
0.5 degrees above the temperature you set, your Room Thermostat
turns off the heating unit, and if it falls below 0.5 degrees, it turns on
theheating unit.
FH104 AND EQUIPMENTS
230V AC
FH104 Room Thermostat
Dowels and
Screws
WIRING DIAGRAM FOR WIRING CENTER
If the floor sensor measures temperature above 28°C, it turns off the
heating unit. The floor sensor operating sensitivityis ±1°C.*
Thus, it is ensured that the ambient temperature remains within a
certain range.
N
L
L1
N1
*Externalfloor sensor is only activewhen itis connected.
TECHNICAL DATA
Note: If a floor sensor is installed with Room Thermostat, only
GENERAL Life floor sensor should be installed. Otherwise, the
product willbe out of warranty.
Dimensions ( H / L / W )
Operating Current
Relay NO Switching Current
85.7mm / 85.7mm / 33.5mm
230V AC
7A (240VAC – Resistive load)
10A (120VAC – Resistive load)
0.1oC
ROOM THERMOSTAT WIRING DIAGRAM
Temperature Measurement
Accuracy
1
2
3
4
Operating Sensitivity
Operating Temperature Range
Operating Temperature
Storage Temperature
0.5oC
(5oC) – (30oC)
(-10oC) – (+50oC)
(-20oC) – (+60oC)
WIRING
CENTER
230V AC
ROOM THERMOSTAT
WARNING!
Indicator LED
Set Button
Operations related to the control panel, heating unit or electrical
installation must be carried out by persons with professional
qualifications.
5
N
L
NTC
L1
N1
WARNING!
6
RoomThermostatIndicator LED Descriptions
The assembly of product
LED light is on
LED light is off
Heating unit is working
should be done according to
the image above.
Heating unit is not working
For electrical connection,
please see diagram 5.
Should not be used in case
the usage of a wiring center.
generallife.com.tr
1
2
3
| General | Details |
|---|---|
| Name | GENERAL LIFE FH104 Underfloor Heating Thermostat User Manual |
| Make | GENERAL LIFE |
| Language | English |
| Filetype | PDF (Download) |
| File size | 1.97 MB |

GENERAL LIFE HT330S RF Room Thermostat User Manual

GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual

GENERAL LIFE HT250 RF Digital Room Thermostat User Manual

GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual

GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual

GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual

GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual

GENERAL LIFE 270S RF Room Thermostat User Manual

GENERAL LIFE 270 Wireless Room Thermostat User Manual

GENERAL LIFE HT220S RF Digital Room Thermostat User Manual

GENERAL LIFE FH104 Underfloor Heating Thermostat User Manual Overview
Summary of Contents
- Page 1: Room thermostat placement Place your Room Thermostat in a room you use frequently in your living space. Avoid installing the Room Thermostat in places where there is a lot of air circulation, such as at the doorway or by the window. General specifications FH104 is a floor heating room thermostat. User provides more comfortable and affordable heating by setting needed room temperature. Room thermostat working principle As soon as you energize your Room Thermostat, it will start working. Your Room Thermostat measures the temperature of the environment it is in every 5 seconds. If the floor sensor measures temperature above 28°C, it turns off the heating unit. The floor sensor operating sensitivity is ±1°C. Technical data If a floor sensor is installed with Room Thermostat, only General Life floor sensor should be installed. Warning! Operations related to the control panel, heating unit or electrical installation must be carried out by persons with professional qualifications. Room thermostat indicator LED descriptions Heating unit is working when the LED light is on. Heating unit is not working when the LED light is off. For electrical connection, please see the diagram. Should not be used in case of the usage of a wiring center.
- Page 2: Warranty certificate Declaration of conformity Devices and their apparatus are out of warranty if they are beaten, broken, or scratched by the customer. Damages resulting from the use of devices and apparatus belonging to other brands and models without the approval of the manufacturer are not covered by the warranty. Battery leakage and errors due to rust, oxidation, and liquid contact by working in acidic/humid environments are not covered by the warranty. Damages that may occur during the transportation of devices and apparatus are not covered by the warranty. The warranty period starts from the invoice date and is valid against manufacturing defects for 2 years. The repair of the devices and apparatus covered by the warranty is carried out in the company factory. In case of malfunctioning of the devices and apparatus whose warranty period continues, it is tested in the company whether the malfunction is caused by a customer or manufacturer fault. Malfunctions resulting from the use of devices and apparatus contrary to the matters stated in the user manual are not covered by the warranty.