Danfoss Next Plus Electronic Intelligent Timer Thermostat Installation Guide
| General | Details |
|---|---|
| Name | Danfoss Next Plus Electronic Intelligent Timer Thermostat Installation Guide |
| Make | Danfoss |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.69 MB |

Danfoss RET-MD Electronic Intelligent Dial Setting Thermostat Installation Guide
Danfoss VICUQ24M Icon Programmable II Room Thermostat Installation Guide

Danfoss MBC 8000, MBC 8100 Heavy Duty Thermostat Installation Guide

Danfoss UT 72-UT 73 Universal Thermostat Installation Guide

Danfoss ECtemp 530 Electronic Thermostat Installation Guide

Danfoss 014G0251 Eco Radiator Thermostat User Guide

Danfoss 014G0013 Z Wave Radiator Thermostat Installation Guide

Danfoss RET230P Electronic Thermostat Instruction Manual

Danfoss TP7000 Range Electronic 7 Day Programmable Room Thermostat Installation Guide

Danfoss RET1000 Series Electronic Thermostat User Guide

Danfoss Next Plus Manual: Questions and Answers
Danfoss Next Plus specifications
| Power supply | 85-250V~, 50/60 Hz |
| Maximum load | Max. 16 A / 3680 W @ 230 V |
| Floor temperature limit | Max. 35°C |
| Setpoint range | Room temperature: 5-35°C |
| Sensor | Floor Sensor NTC 15 kΩ |
| Operating temperature | -10°C to +60°C |
| Storage temperature | -20°C to +65°C |
| Dimensions | 86 x 86 x 16/40.5 mm |
| Weight | 103 g |
| Power consumption | 0,4 W |
What voltage does the Danfoss Next Plus operate at?
85-250V~, 50/60 Hz.
What do the symbols mean on a Danfoss Next display?
| Symbol | Meaning |
|---|---|
| Room temperature | Current air temperature measured by room sensor |
| Floor temperature | Current temperature measured by floor sensor |
| Temperature indication | Set temperature value |
| Away mode | Thermostat in away mode |
| Child safety lock | Controls locked to prevent accidental changes |
| Power ON/OFF | Thermostat powered on or off |
Can I use the Danfoss Next Plus with only a room sensor, or is a floor sensor required?
Only a floor sensor is mandatory under wooden floors to reduce overheating risk. Using only a room sensor is possible but not recommended due to increased floor overheating risk. Installation Guide, p. 6
What does SET mean when it appears on the Danfoss Next Plus display?
SET appears when you press the temperature adjustment buttons. It indicates a temporary temperature change that will be maintained only until the next programmed setting. Installation Guide, p. 11
Danfoss Next Plus compared with other Danfoss thermostats
| Specification | Danfoss Next Plus | Danfoss 220V Electronic Intelligent Timer Thermostat | Danfoss DEVIreg 316 | Danfoss DEVIreg 530 |
|---|---|---|---|---|
| Power supply | 85-250V~, 50/60 Hz | 220-240 V~, 50/60 Hz | 220 - 240V~, 50Hz | 220-240V~, 50Hz |
| Setpoint range | Room temperature: 5-35°C | Room temperature: 5-35°C | -10 ° to +50 °C | 5-45°C with floor |
| Sensor | Floor Sensor NTC 15 kΩ | NTC 6.8 k at 25°C | NTC 15 kOhm at 25 °C | NTC 15kOhm at 25°C |
| Operating temperature | -10°C to +60°C | 0° to +30°C | -10 °C to +45 °C | -10 to +30°C |
| Storage temperature | -20°C to +65°C | -20°C to +65°C | -20 °C to +65 °C | -20 to +65°C |
| Dimensions | 86 x 86 x 16/40.5 mm | 85 x 85 x 20-24 mm | 86 x 36 x 58 mm | 85 x 85 x 36 mm |
| Weight | 103 g | 103 g | 180 g | 90 g |
| Power consumption | 0,4 W | Max. 0.40 W | Max 0.25W | Max 0.25W |