Danfoss Next Plus Electronic Intelligent Timer Thermostat Installation Guide
Danfoss ECtemp Next Plus
P03 Maximum floor
temperature
20-30˚C (only for 01 in
P02)**
35˚C
P04 Frost protection
01: Enable; 02: Disable
5-9˚C
01
P05 Frost protection
setpoint
5˚C
P06 Timer display option 01: 24h; 02 12h
01
01
P07 Room temp. display
option at shutdown
01: No display surrent
temp.;
02: Display current temp.
* It will be possible to use only a room sensor. However, this option is not recom-
mendable due to an increased risk of overheating the floor. See 4.9 Change to
Room control only
** P03 appears on relevant temperature control mode. See 4.10 Extending
Maximum floor temperature limitations to 45°C
4.3 Advanced Programmable Timer
The Advanced Programmable Timer mode enables the set-
ting of a timer-controlled program for automatic comfort
temperature, and an energy-saving lower setback tempera-
ture if standard room comfort temperature is not required.
The function consists of 2 programs:
P1 with 4 events in 5 days
(Mon. Tue. Wed. Thu. Fri.)
P2 with 4 events in 2 days (Sat.
Sun.).
10
Installation Guide
| General | Details |
|---|---|
| Name | Danfoss Next Plus Electronic Intelligent Timer Thermostat Installation Guide |
| Make | Danfoss |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.69 MB |

Danfoss RET-MD Electronic Intelligent Dial Setting Thermostat Installation Guide
Danfoss VICUQ24M Icon Programmable II Room Thermostat Installation Guide

Danfoss MBC 8000, MBC 8100 Heavy Duty Thermostat Installation Guide

Danfoss UT 72-UT 73 Universal Thermostat Installation Guide

Danfoss ECtemp 530 Electronic Thermostat Installation Guide

Danfoss 014G0251 Eco Radiator Thermostat User Guide

Danfoss 014G0013 Z Wave Radiator Thermostat Installation Guide

Danfoss RET230P Electronic Thermostat Instruction Manual

Danfoss TP7000 Range Electronic 7 Day Programmable Room Thermostat Installation Guide

Danfoss RET1000 Series Electronic Thermostat User Guide