Danfoss Next Plus Electronic Intelligent Timer Thermostat Installation Guide
Danfoss ECtemp Next Plus
The thermostat should not be placed in wet rooms.
Place it in an adjacent room and use floor sensor
only. Always place the thermostat according to local
regulation on IP classes and use floor sensor only.
Do not place the thermostat on the inner side of an
exterior wall.
Always install the thermostat at least 50 cm. from
windows and doors.
Do not place the thermostat in a way that it will be
exposed to direct sunlight.
Note: A floor sensor enables a more accurate
temperature control and is recommended in all floor
heating applications and mandatory under wooden
floors to reduce the risk of over-heating the floor.
•
Place the floor sensor in a conduit in an appropriate place
where it is not exposed to sunlight or draft from door
openings.
•
•
Equally distant and >2cm from two heating cables.
The conduit should be flush with the floor surface -
countersink the conduit if necessary.
•
Route the conduit to the connection box.
6
Installation Guide
| General | Details |
|---|---|
| Name | Danfoss Next Plus Electronic Intelligent Timer Thermostat Installation Guide |
| Make | Danfoss |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.69 MB |

Danfoss RET-MD Electronic Intelligent Dial Setting Thermostat Installation Guide
Danfoss VICUQ24M Icon Programmable II Room Thermostat Installation Guide

Danfoss MBC 8000, MBC 8100 Heavy Duty Thermostat Installation Guide

Danfoss UT 72-UT 73 Universal Thermostat Installation Guide

Danfoss ECtemp 530 Electronic Thermostat Installation Guide

Danfoss 014G0251 Eco Radiator Thermostat User Guide

Danfoss 014G0013 Z Wave Radiator Thermostat Installation Guide

Danfoss RET230P Electronic Thermostat Instruction Manual

Danfoss TP7000 Range Electronic 7 Day Programmable Room Thermostat Installation Guide

Danfoss RET1000 Series Electronic Thermostat User Guide