Network Thermostat X7C-WIFI Smart Touchscreen Thermostat Instruction Manual
CO2: 855 ppm
X7C-WIFI
• Commercial Grade Wi-Fi Thermostat
• Gas/Electric to 2H/2C, Heat Pump to 3H/2C
• Humidity Sensing and Control
• CO2 Sensing and Control
• Advanced Remote Sensor Bus
• Two Configurable Relays
• Full Color Touchscreen
• 7 Day Programmable ~ 4 Events/Day
• 80 Additional Event Schedules
• Onboard Data Logging
• BACnet/IP and Modbus TCP/IP Included
Complete Stand-Alone Solution
GENERAL DESCRIPTION:
The X7C-WIFI is a commercial grade Wi-Fi color touchscreen thermostat with an advanced remote sensor bus, designed
for new or replacement applications. Use the X7C for either conventional and heat pump applications (Gas/Elect 2H/2C,
HP 3H/2C), along with humidification, fresh air damper, IAQ controls and more. The X7C also includes a revolutionary
CO2 sensor, with no field calibration needed for five (5) years. DirectConnect™ helps deliver a near-effortless setup of
your daily schedules (4 events per day) and up to 80 Additional Events (40 Special and 40 Calendar Events). The unique
scheduling structure also supports the powerful features of adjustable temporary override times and temperature ranges,
occupied and unoccupied events, keypad lockout, and many more features. The X7C-WIFI also includes full BACnet/IP
support over Wi-FI, directly on the thermostat.
The X7C-WIFI is designed to operate with our CloudConnect™ Online Management software or, for maximum security,
behind your firewall using DirectConnect™ or our PCConnect™ Software. Since all HVAC functions are stored in the
thermostat, the X7C will continue to operate even during network outages, allowing you to maintain your energy savings.
For ultimate control over energy usage, the X7C offers a digital lockout that can permit limited temperature overrides based
on your requirements. Our on-board data collection allows for historical review, sub-metering, and run-time reporting.
CloudConnect™ & CloudManager™ Available
STANDARD FEATURES:
Energy Savings
Facility Management
●
Efficient Equipment Restart™ randomizes equipment starts to minimize
multiple units turning on simultaneously when there are multiple NetX
thermostats at the location
●
●
●
4 independent schedules per day
80 Additional Schedules (40 Special and 40 Calendar Events)
Commercial Lockout with Programmable Temporary Override Time and
Temp Adjustment
●
●
Random Restart on power up staggers restart of HVAC system after a
power outage to minimize peak inrush current
●
●
Email & Text Message Alerting for 4 Recipients
Alerts include Hi/Lo Temps for Indoor, Outdoor, Supply, Return, and Aux
Temps, Inefficient Equipment Runs, Change Filter Notifications, and Two
Digital Inputs: 19 Alerts in All
Adaptive Recovery for Schedules allows system to achieve desired
setpoint at the beginning of the schedule
Monitoring
●
14 Remote Sensors: up to 6 indoor, 1 humidity, 1 outdoor, up to 3
General
auxiliary sensors for monitoring supply air, return air, walk-in
refrigerators and freezers, etc., plus water leak sensing.
CO2 current and max level display and recording. Meets CA Energy
Commission requirements.
●
●
●
Color Selectable Touchscreen Display, Black or White Case
Modes: Heat, Cool, Automatic Changeover
Integrated Humidity Sensor & Humidification and Dehumidification
Control
●
●
●
●
2 Digital Inputs for Fault Condition Alerting
●
●
Fan Selector for Automatic and Manual Operation; Programmable
Recirculation Fan
Occupancy Sensor Input
On-board Data Logging with Sub-Metering Support
Relay 1 & Relay 2 Flexible Control
○
○
○
○
Humidification and Dehumidification Control
Fresh-Air Damper Control
IAQ Equipment Control Control
Auxiliary General Purpose Relays
with Scheduling
Connectivity
●
●
●
●
●
●
CloudConnect™ Internet-Based Cloud Service
PCConnect™ Software Local Network & Port Forwarded Access
DirectConnect™ Integrated Web Server
●
Integrated Weather with Current Conditions and
7-Day Forecasts
Integrated NetX™ API, Supports 3rd Party Apps
BACnet/IP and Modbus TCP/IP Embedded
Optional Modbus RTU Interface via NT-485 Module
972-580-8001
© 2023 Network Thermostat, Grapevine, TX
P/N 240324-04
| General | Details |
|---|---|
| Name | Network Thermostat X7C-WIFI Smart Touchscreen Thermostat Instruction Manual |
| Make | Network Thermostat |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.25 MB |

Network Thermostat X7-Series Thermostat Installation Guide

Network Thermostat X5-WIFI Smart Touchscreen Thermostat Instruction Manual

Network Thermostat NetXTM X-Series Thermostat Installation Guide

network thermostat NetX X5-CFA Universal Setback Thermostat Instruction Manual

network thermostat NetX X Series Thermostat Instruction Manual

network thermostat NetX X-Series Ethernet Thermostat Owner’s Manual

network thermostat X-Series Ethernet Thermostat Instruction Manual

Network Thermostat NetX X7 Series Thermostat Instruction Manual

network thermostat X X7-WIFI Smart Touchscreen Thermostat Instructions

Network Thermostat X7C-WIFI Smart Touchscreen Thermostat Instruction Manual Overview
Summary of Contents
- Page 1: CO2: 855 ppm X7C-WIFI Commercial grade Wi-Fi thermostat Gas/Electric to 2H/2C, heat pump to 3H/2C Humidity sensing and control CO2 sensing and control Advanced remote sensor bus Full color touchscreen 7 day programmable with 4 events per day Onboard data logging
- Page 2: Specifications: Rated voltage: 20V to 30VAC, 24VAC nominal. Rated A.C. / D.C. current: 0.05 to 0.75 AC / 0.0 to 0.75 DC Amp continuous, surges to 3 Amps maximum. Temperature control range: Heating 38 to 88°F (6 to 30°C), Cooling 60 to 108°F (16 to 40°C). Thermostat sensing range: 20 to 124°F (0 to 48°C) with control accuracy of +/-1°F @ 68°F. Humidity sensing range: 0% - 100% RH with accuracy of ±3% from 10% - 90%. Humidity control range: Humidify 10% to 60%RH, Dehumidify 35% to 75%RH. Dimensions: 5.1”H x 4.7”W x 1.15”D (128mm x 119mm x 29mm). Wireless radio protocols: 2.4GHz 802.11b/g/n, with security options including Open, WEP, WPA-PSK, WPA2-PSK. Terminal functions include various inputs and outputs for HVAC connections. Note: Check heat pump installation instructions for reversing valve connection.