Home > GENERAL LIFE > GENERAL LIFE Therma 300S RF Wireless Room Thermostat User Manual
GENERAL LIFE Therma 300S RF Wireless Room Thermostat User Manual
ScreenIndicators
BATTERY PLACEMENT
If the pairing is successful, the green flashing LED on the receiver will be
constant.
ENGLISH
1
2
3
4
Receiverand Room Thermostathavebeen pairedto eachother.
10
11
DIGITAL ROOM THERMOSTAT
ROOM THERMOSTATTEMPERATURE CALIBRATION
12
Temperature sensors which are used in Room Thermostats are highly sensitive.
You may need to calibrate your Room Thermostat if you would like to get the same
temperaturevalueswithother thermometersin yourliving space.
5
generallife.com.tr
6
7
8
9
While yourdeviceis turned off, pressand hold the"On/Off"button for 3 seconds.
Press the "On/Off" button until the “ ” menu appers. In order to see the desired
As shown in the picture above, press the screwdriver forward from the space
shown, bend the tabs and separate the front cover. Insert 2 new AAA alkaline
batteries in the battery housing with the correct battery direction. Replace both
batteries at the same time. Then align the frontpart of your Room Thermostat to the
backand squeezeittowardstheback.
THERMA 300S RF USER MANUAL
temperature, set the temperature difference by press the “Temperature
AdjustmentButtons”. This valuecan be arranged between“-8oC" and “+8oC".
To savethesettingsand exit, pressthe"On/Off" button until thedeviceturns off.
GENERAL SPECIFICATIONS
Note:Recommended tempreturecalibration is “0.0oC”.
1
2
3
4
5
6
7
8
9
Day Indicator
Hours of Day
Hour Indicator
Screen Lock
Low Battery Warning: When the “
” icon appears on the screen, it means “low
THERMA 300S RF is a wireless room thermostat. The user can adjust the room
temperature with the required temperature and get more comfortable and
economic heating/cooling.
ROOM THERMOSTAT HEATING / COOLING MODES
Your Room Thermostat has heating and cooling modes. In order to switch easily
betweenheating and cooling modes:
battery warning”. Itis recommendedto replacethebatterieswhen this warning
appears.
Room Temperature
Set Temperature
Economy Mode
Comfort Mode
Programming Mode
Cooling Indicator
- If the Cooling Indicator is blinking, the cooling unit is working.
- If the Cooling Indicator is steady, the cooling unit is not working.
Heating Indicator
Warning: When the product is not used for a long period (more than 15 days), remove
thebatteries. Otherwise, malfunctions thatmay occurwouldbeoutof warranty.
Pleasethrowyourdead batteries into thewastebin forbatteries.
Dailyand WeeklyProgram(7x24)
While yourdeviceis turned off, pressand hold the“On/Off” button for 3 seconds.
Pressthe“On / Off” button until the“ ” menu appears.
” (heating) and “ ” (cooling) modes by using the
” menu.
DifferentMode Options (Comfort Mode and EconomyMode)
PreciseTemperatureMeasurement
Heating Calibration
ON/OFFControl
WirelessConnection
TPIAlgorithm
You can switch between “
“Up” or "Down"buttons in the“
RECEIVER PLACEMENT
Heating/Cooling Modes
To save the settings and exit, press the “On / Off” button or wait 10 seconds until
thedeviceturns off.
10
11
The important things to note for the Receiver placement is
avoiding physical contact between the Receiver and
heating/cooling unit, and protectingit against materials such
asliquid, dust etc.
THERMA 300S RF AND EQUIPMENTS
THERMA 300S RF
Room Thermostat
The settings you have made have been saved. Once you turned on your device, it
willoperatewiththechanged settings.
Holder
Alkaline
Battery
- If the Heating Indicator is blinking, the heating unit is working.
- If the Heating Indicator is steady, the heating unit is not working.
Battery Indicator
FACTORY SETTINGS RESET
12
You can reset your Room Thermostat to its default factory settings. This operation
resets the mode temperature values, calibration setting, heating/coling modes and
hysteresis settings to factory setting. To reset your Room Thermostat to factory
setting:
RECEIVER
The devices should be placed in order to minimize the damage to the received and
transmittedsignals bypayingattentiontothefollowingpoints;
The devicesshould not be mounted on metalsurfaces.
1-ManualOperationButton:
1
2
3
The devices should not be installed close to electrical cables and electronic
equipment such ascomputers and televisionunits.
Deactivates the Receiver and allows you to use
heating/cooling unit manually.
2-PairingButton:
While yourdeviceis turned off, pressand hold the"On/Off"button for 3 seconds.
Dowels and Screws
Receiver
Pressthe“On/Off” button until “
” menu appears.
The devices should not be installed near large metal structures or other building
materialsusing finemetalmeshes such as specialglass or specialconcrete.
Distance between the Room Thermostat and the Receiver should not exceed 20
metersor 2 floors.
While in the “
” menu, select the “
” option by using “Up” or “Down” buttons
Allows to pair the Receiver with the Room
Thermostat.
3-Receiver LED Light
4-ReceiverPowerCable Input
5-Heating/CoolingUnit ConnectionCable Input
and pressthe“On/Off” button.
Your devicewillbe turned off and resetto factory settings.
Receivermust be installed atleast50cmawayfromtheheating/cooling unit.
KEY LOCK
In the Room Thermostat there is a key lock function to avoid any unintended
contact.
RECEIVER SETUP
First, shut down your heating/cooling unit and your heating/cooling unit's power
sourcewithallelectricalcurrent(fuse, socketetc.)
TECHNICAL DATA
Room Thermostat
In orderto unlock the Room Thermostat's keylock “Mode”button should be pressed
for 3 seconds. If buttons on Room Thermostat are not touched for 10 seconds, key
lockwillbe reactivated.
4
5
As shown in the connection diagram, connect one end of the heating/cooling unit
connection cabletotheCOMand theother to theNOinput of theReceiver.
Connect the other ends of the cable -which youconnected to the Receiverto room
thermostat connection terminal as shown in your heating/cooling unit's user
manual.
Dimensions
Operating Current
Temperature Measurement Accuracy
Operating Temperature Range
Battery Life
100mm / 160mm / 18.2mm
3V DC (2 x AAA alkaline battery)
RECEIVER LED DESCRIPTIONS
0.1oC
Steady Red
Receiver has power but Receiver and Room
Thermostat are not paired.
(5oC) – (30oC)
1 Year (2 x AAA)
(-10oC) – (+50oC)
(-20oC) – (+60oC)
DAY AND HOUR SETTINGS
While your Room Thermostat is on, keep pressing ''Settings'' button for
seconds.
3
Blinking Green
Steady Green
Waiting for pairing signal from the Room Thermostat.
Receiver and Room Thermostat are paired.
Heating/cooling unit is not operating.
Operate the heating/cooling unit signal has
reached to the Receiver.
Heating/cooling unit is operating.
Shut the heating/cooling unit down signal has
reached to the Receiver.
Operating Temperature
Storage Temperature
You must first connect the Receiver power cable to the Receiver and then to the
fuse to which theheating/cooling unit is connected.
At the first screen that appears ''Hour'' part will be blinking. You may set the time
with“Up” and “Down”buttons.
3 Short Orange
Blinking
Steady Orange
3 Short Green
Blinking
After completing the cable connection process, firstly turn on your fuse and then
yourheating/cooling unit.
After setting the time, ''Settings'' button needs to be pressed once. For minute
setting, minute part will be blinking. You may set the minute with “Up” and “Down”
buttons.
Receiver
By pressing the Receiver's manual usage button for 2 seconds, you should see
the Orange Light blinking on the Receiver. In this way, after making sure that the
heating/cooling unit is operating, press the same button again for 2 seconds and
seethattheOrange LEDturns off.
Dimensions
Operation Current
Relay NO Switching Current
90mm / 90mm / 25mm
230V AC
7A (240VAC – Resistive load)
10A (120VAC – Resistive load)
(-20oC) – (+60oC)
Blinking Orange
Heating/Cooling unit operates in manual mode.
Aftersetting the minute, ''Settings'' button needs to be pressedonce to set the day
of theweek.
Blinking Red
Receiver did not get any signal from the Room
Thermostat for 22 minutes or longer.
Heating/cooling unit has shut down.
Storage Temperature
Mondayhas setasthefirstdayof theweekand indicated withnumber “1".
Numbers indicates the following days respectively 2-Tuesday, 3-Wednesday,
4-Thursday, 5-Friday, 6-Saturdayand 7-Sunday
Setup theRoom Thermostatto pair theReceiverwiththeRoom Thermostat.
AC
RECEIVER WIRING DIAGRAM
ROOM THERMOSTAT
Buttons Functions
ROOM THERMOSTAT PLACEMENT
COM
NO
(230V)
When settingis done youmayexitbypressingfor 3 seconds to “Settings”button.
Room Thermostat needs to be placed in the room which is used most frequently.
For instance; living room or lounge. Placing the Room Thermostat in a spot that
have air circulation like entrance of a room or side of window should be avoided.
Also anywhere close to heating/cooling units such as radiator, stove and spots
which get direct sun lights would not be suitable. Room Thermostat needs to be
located above the floor 150 cm height. Few trials may be made to find the most
convenientspot.
MODE SETTTINGS
MODES
1
2
3
PRESET MODES
MANUAL MODE
WEEKLY
PROGRAM
MODE
4
5
6
Comfort
Mode
Economy
Mode
HEATING/COOLING UNIT
Your Room Thermostat has 4 different modes. Two of them(Comfort and Economy
Mode)arepresetmodes. Othermodes aremanual mode and programmingmode.
In preset modes, temperature values are based on user's choices which has been
set in the beginning. Manual mode provides to operate the Room Thermostat with
temperature which user's required and set directly. Programming mode continues
toworkaccordingto theweeklyprogramdetermined bytheuser.
Warning!
Operations within the heating / cooling unit or the electrical installation must be
carriedout byprofessionally qualified persons.
1
2
3
4
5
6
On/Off Button
PAIRING THE ROOM THERMOSTAT AND THE RECEIVER
Temperature Adjustment (To Increase)
Temperature Adjustment (To Decrease)
Weekly Program Button
Setting Button
Mode Button – Unlock Button
Primarily press the sync button of receiver for 2 seconds and see blinking green
light of receiver.
Temperaturevaluesof presetmodes can be changed on “Settings”menu.
In order to go to “Settings” menu, “Settings” button needs to be pressed for 3
seconds. Date and time settings would appear in first screen, to skip it “Settings”
button should be pressedfor 3 times.
While yourdeviceis turned off, pressand hold the"On/Off"button for 3 seconds.
Pressthebutton until the“
” menu appears.
Press the “Up” or “Down” button of your Room Thermostat while the LED is
flashing green.
Comfort Mode's “
” temperature value would appear and temperature for
Comfort Mode can be adjusted bypressing“Up” and “Down”buttons.
1
2
3
4
| General | Details |
|---|---|
| Name | GENERAL LIFE Therma 300S RF Wireless Room Thermostat User Manual |
| Make | GENERAL LIFE |
| Language | English |
| Filetype | PDF (Download) |
| File size | 2.23 MB |

GENERAL LIFE HT330S RF Room Thermostat User Manual

GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual

GENERAL LIFE HT250 RF Digital Room Thermostat User Manual

GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual

GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual

GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual

GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual

GENERAL LIFE HT220S RF Digital Room Thermostat User Manual

GENERAL LIFE 270S RF Room Thermostat User Manual

GENERAL LIFE 270 Wireless Room Thermostat User Manual

GENERAL LIFE Therma 300S RF Wireless Room Thermostat User Manual Overview
Summary of Contents
- Page 1: Battery placement is essential for the device's operation. If pairing is successful, the green flashing LED on the receiver will be constant. Temperature sensors in room thermostats are highly sensitive and may require calibration. Recommended temperature calibration is “0.0°C”. The device has heating and cooling modes that can be switched easily. A low battery warning appears when the battery is low, indicating it's time for replacement. The receiver must be installed at least 50 cm away from the heating/cooling unit. The room thermostat should be placed in a frequently used room, avoiding areas with direct sunlight or near heating/cooling units. Operations within the heating/cooling unit must be carried out by qualified persons. The room thermostat has a key lock function to prevent unintended contact.
- Page 2: WARRANTY CONDITIONS The warranty period starts from the invoice date and is warranted against manufacturing defects for 5 years. Devices and apparatus are delivered to the customer in working condition. On-site commissioning is subject to a service fee. The repair of the devices and apparatus covered by the warranty is carried out in our company factory. The maintenance of devices and apparatus is done in our company, and the round travel fares belong to the customer. In case of malfunctioning of the devices and apparatus whose warranty period continues, it is tested in our company whether the malfunction is caused by a customer or manufacturer fault. Customers should be aware of damages of the product and warn the manufacturer since the day warranty duration starts. Malfunctions resulting from the use of devices and apparatus contrary to the matters stated in the User Manual are not covered by the warranty. Devices and their apparatus are out of warranty if they are beaten, broken, or scratched by the customer. Your Room Thermostat works with the TPI algorithm, predicting when the temperature of your home will rise above or below the set temperature. TPI technology is designed to ensure that you get the best possible energy efficiency from your heating/cooling system.