Home > GENERAL LIFE > GENERAL LIFE Therma 300S RF Wireless Room Thermostat User Manual

GENERAL LIFE Therma 300S RF Wireless Room Thermostat User Manual

ScreenIndicators  
BATTERY PLACEMENT  
If the pairing is successful, the green flashing LED on the receiver will be  
constant.  
ENGLISH  
1
2
3
4
Receiverand Room Thermostathavebeen pairedto eachother.  
10  
11  
DIGITAL ROOM THERMOSTAT  
ROOM THERMOSTATTEMPERATURE CALIBRATION  
12  
Temperature sensors which are used in Room Thermostats are highly sensitive.  
You may need to calibrate your Room Thermostat if you would like to get the same  
temperaturevalueswithother thermometersin yourliving space.  
5
generallife.com.tr  
6
7
8
9
While yourdeviceis turned off, pressand hold the"On/Off"button for 3 seconds.  
Press the "On/Off" button until the “ ” menu appers. In order to see the desired  
As shown in the picture above, press the screwdriver forward from the space  
shown, bend the tabs and separate the front cover. Insert 2 new AAA alkaline  
batteries in the battery housing with the correct battery direction. Replace both  
batteries at the same time. Then align the frontpart of your Room Thermostat to the  
backand squeezeittowardstheback.  
THERMA 300S RF USER MANUAL  
temperature, set the temperature difference by press the “Temperature  
AdjustmentButtons”. This valuecan be arranged between-8oC" and “+8oC".  
To savethesettingsand exit, pressthe"On/Off" button until thedeviceturns off.  
GENERAL SPECIFICATIONS  
Note:Recommended tempreturecalibration is “0.0oC”.  
1
2
3
4
5
6
7
8
9
Day Indicator  
Hours of Day  
Hour Indicator  
Screen Lock  
Low Battery Warning: When the “  
” icon appears on the screen, it means “low  
THERMA 300S RF is a wireless room thermostat. The user can adjust the room  
temperature with the required temperature and get more comfortable and  
economic heating/cooling.  
ROOM THERMOSTAT HEATING / COOLING MODES  
Your Room Thermostat has heating and cooling modes. In order to switch easily  
betweenheating and cooling modes:  
battery warning”. Itis recommendedto replacethebatterieswhen this warning  
appears.  
Room Temperature  
Set Temperature  
Economy Mode  
Comfort Mode  
Programming Mode  
Cooling Indicator  
- If the Cooling Indicator is blinking, the cooling unit is working.  
- If the Cooling Indicator is steady, the cooling unit is not working.  
Heating Indicator  
Warning: When the product is not used for a long period (more than 15 days), remove  
thebatteries. Otherwise, malfunctions thatmay occurwouldbeoutof warranty.  
Pleasethrowyourdead batteries into thewastebin forbatteries.  
Dailyand WeeklyProgram(7x24)  
While yourdeviceis turned off, pressand hold theOn/Off” button for 3 seconds.  
PresstheOn / Off” button until the menu appears.  
” (heating) and “ ” (cooling) modes by using the  
” menu.  
DifferentMode Options (Comfort Mode and EconomyMode)  
PreciseTemperatureMeasurement  
Heating Calibration  
ON/OFFControl  
WirelessConnection  
TPIAlgorithm  
You can switch between “  
“Up” or "Down"buttons in the“  
RECEIVER PLACEMENT  
Heating/Cooling Modes  
To save the settings and exit, press the “On / Off” button or wait 10 seconds until  
thedeviceturns off.  
10  
11  
The important things to note for the Receiver placement is  
avoiding physical contact between the Receiver and  
heating/cooling unit, and protectingit against materials such  
asliquid, dust etc.  
THERMA 300S RF AND EQUIPMENTS  
THERMA 300S RF  
Room Thermostat  
The settings you have made have been saved. Once you turned on your device, it  
willoperatewiththechanged settings.  
Holder  
Alkaline  
Battery  
- If the Heating Indicator is blinking, the heating unit is working.  
- If the Heating Indicator is steady, the heating unit is not working.  
Battery Indicator  
FACTORY SETTINGS RESET  
12  
You can reset your Room Thermostat to its default factory settings. This operation  
resets the mode temperature values, calibration setting, heating/coling modes and  
hysteresis settings to factory setting. To reset your Room Thermostat to factory  
setting:  
RECEIVER  
The devices should be placed in order to minimize the damage to the received and  
transmittedsignals bypayingattentiontothefollowingpoints;  
The devicesshould not be mounted on metalsurfaces.  
1-ManualOperationButton:  
1
2
3
The devices should not be installed close to electrical cables and electronic  
equipment such ascomputers and televisionunits.  
Deactivates the Receiver and allows you to use  
heating/cooling unit manually.  
2-PairingButton:  
While yourdeviceis turned off, pressand hold the"On/Off"button for 3 seconds.  
Dowels and Screws  
Receiver  
PresstheOn/Off” button until “  
” menu appears.  
The devices should not be installed near large metal structures or other building  
materialsusing finemetalmeshes such as specialglass or specialconcrete.  
Distance between the Room Thermostat and the Receiver should not exceed 20  
metersor 2 floors.  
While in the “  
” menu, select the “  
” option by using “Up” or “Down” buttons  
Allows to pair the Receiver with the Room  
Thermostat.  
3-Receiver LED Light  
4-ReceiverPowerCable Input  
5-Heating/CoolingUnit ConnectionCable Input  
and presstheOn/Off” button.  
Your devicewillbe turned off and resetto factory settings.  
Receivermust be installed atleast50cmawayfromtheheating/cooling unit.  
KEY LOCK  
In the Room Thermostat there is a key lock function to avoid any unintended  
contact.  
RECEIVER SETUP  
First, shut down your heating/cooling unit and your heating/cooling unit's power  
sourcewithallelectricalcurrent(fuse, socketetc.)  
TECHNICAL DATA  
Room Thermostat  
In orderto unlock the Room Thermostat's keylock “Modebutton should be pressed  
for 3 seconds. If buttons on Room Thermostat are not touched for 10 seconds, key  
lockwillbe reactivated.  
4
5
As shown in the connection diagram, connect one end of the heating/cooling unit  
connection cabletotheCOMand theother to theNOinput of theReceiver.  
Connect the other ends of the cable -which youconnected to the Receiverto room  
thermostat connection terminal as shown in your heating/cooling unit's user  
manual.  
Dimensions  
Operating Current  
Temperature Measurement Accuracy  
Operating Temperature Range  
Battery Life  
100mm / 160mm / 18.2mm  
3V DC (2 x AAA alkaline battery)  
RECEIVER LED DESCRIPTIONS  
0.1oC  
Steady Red  
Receiver has power but Receiver and Room  
Thermostat are not paired.  
(5oC) – (30oC)  
1 Year (2 x AAA)  
(-10oC) – (+50oC)  
(-20oC) – (+60oC)  
DAY AND HOUR SETTINGS  
While your Room Thermostat is on, keep pressing ''Settings'' button for  
seconds.  
3
Blinking Green  
Steady Green  
Waiting for pairing signal from the Room Thermostat.  
Receiver and Room Thermostat are paired.  
Heating/cooling unit is not operating.  
Operate the heating/cooling unit signal has  
reached to the Receiver.  
Heating/cooling unit is operating.  
Shut the heating/cooling unit down signal has  
reached to the Receiver.  
Operating Temperature  
Storage Temperature  
You must first connect the Receiver power cable to the Receiver and then to the  
fuse to which theheating/cooling unit is connected.  
At the first screen that appears ''Hour'' part will be blinking. You may set the time  
withUp” and “Downbuttons.  
3 Short Orange  
Blinking  
Steady Orange  
3 Short Green  
Blinking  
After completing the cable connection process, firstly turn on your fuse and then  
yourheating/cooling unit.  
After setting the time, ''Settings'' button needs to be pressed once. For minute  
setting, minute part will be blinking. You may set the minute with “Up” and “Down”  
buttons.  
Receiver  
By pressing the Receiver's manual usage button for 2 seconds, you should see  
the Orange Light blinking on the Receiver. In this way, after making sure that the  
heating/cooling unit is operating, press the same button again for 2 seconds and  
seethattheOrange LEDturns off.  
Dimensions  
Operation Current  
Relay NO Switching Current  
90mm / 90mm / 25mm  
230V AC  
7A (240VAC – Resistive load)  
10A (120VAC – Resistive load)  
(-20oC) – (+60oC)  
Blinking Orange  
Heating/Cooling unit operates in manual mode.  
Aftersetting the minute, ''Settings'' button needs to be pressedonce to set the day  
of theweek.  
Blinking Red  
Receiver did not get any signal from the Room  
Thermostat for 22 minutes or longer.  
Heating/cooling unit has shut down.  
Storage Temperature  
Mondayhas setastherstdayof theweekand indicated withnumber “1".  
Numbers indicates the following days respectively 2-Tuesday, 3-Wednesday,  
4-Thursday, 5-Friday, 6-Saturdayand 7-Sunday  
Setup theRoom Thermostatto pair theReceiverwiththeRoom Thermostat.  
AC  
RECEIVER WIRING DIAGRAM  
ROOM THERMOSTAT  
Buttons Functions  
ROOM THERMOSTAT PLACEMENT  
COM  
NO  
(230V)  
When settingis done youmayexitbypressingfor 3 seconds to “Settingsbutton.  
Room Thermostat needs to be placed in the room which is used most frequently.  
For instance; living room or lounge. Placing the Room Thermostat in a spot that  
have air circulation like entrance of a room or side of window should be avoided.  
Also anywhere close to heating/cooling units such as radiator, stove and spots  
which get direct sun lights would not be suitable. Room Thermostat needs to be  
located above the floor 150 cm height. Few trials may be made to find the most  
convenientspot.  
MODE SETTTINGS  
MODES  
1
2
3
PRESET MODES  
MANUAL MODE  
WEEKLY  
PROGRAM  
MODE  
4
5
6
Comfort  
Mode  
Economy  
Mode  
HEATING/COOLING UNIT  
Your Room Thermostat has 4 different modes. Two of them(Comfort and Economy  
Mode)arepresetmodes. Othermodes aremanual mode and programmingmode.  
In preset modes, temperature values are based on user's choices which has been  
set in the beginning. Manual mode provides to operate the Room Thermostat with  
temperature which user's required and set directly. Programming mode continues  
toworkaccordingto theweeklyprogramdetermined bytheuser.  
Warning!  
Operations within the heating / cooling unit or the electrical installation must be  
carriedout byprofessionally qualified persons.  
1
2
3
4
5
6
On/Off Button  
PAIRING THE ROOM THERMOSTAT AND THE RECEIVER  
Temperature Adjustment (To Increase)  
Temperature Adjustment (To Decrease)  
Weekly Program Button  
Setting Button  
Mode Button – Unlock Button  
Primarily press the sync button of receiver for 2 seconds and see blinking green  
light of receiver.  
Temperaturevaluesof presetmodes can be changed on “Settingsmenu.  
In order to go to “Settings” menu, “Settings” button needs to be pressed for 3  
seconds. Date and time settings would appear in first screen, to skip it “Settings”  
button should be pressedfor 3 times.  
While yourdeviceis turned off, pressand hold the"On/Off"button for 3 seconds.  
Pressthebutton until the“  
” menu appears.  
Press the “Up” or “Down” button of your Room Thermostat while the LED is  
flashing green.  
Comfort Mode's “  
” temperature value would appear and temperature for  
Comfort Mode can be adjusted bypressingUp” and “Downbuttons.  
1
2
3
4
GeneralDetails
NameGENERAL LIFE Therma 300S RF Wireless Room Thermostat User Manual
MakeGENERAL LIFE
LanguageEnglish
FiletypePDF (Download)
File size2.23 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
GENERAL LIFE HT330S RF Room Thermostat User Manual
GENERAL LIFE HT330S RF Room Thermostat User Manual
GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual
GENERAL LIFE HT250 RF Digital Room Thermostat User Manual
GENERAL LIFE HT250 RF Digital Room Thermostat User Manual
GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual
GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual
GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual
GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual
GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual
GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual
GENERAL LIFE HT220S RF Digital Room Thermostat User Manual
GENERAL LIFE HT220S RF Digital Room Thermostat User Manual
GENERAL LIFE 270S RF Room Thermostat User Manual
GENERAL LIFE 270S RF Room Thermostat User Manual
GENERAL LIFE 270 Wireless Room Thermostat User Manual
GENERAL LIFE 270 Wireless Room Thermostat User Manual

GENERAL LIFE Therma 300S RF Wireless Room Thermostat User Manual
Get the free PDF manual for the GENERAL LIFE Therma 300S RF Wireless Room Thermostat User Manual and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

GENERAL LIFE Therma 300S RF Wireless Room Thermostat User Manual Overview

Summary of Contents

  • Page 1: Battery placement is essential for the device's operation. If pairing is successful, the green flashing LED on the receiver will be constant. Temperature sensors in room thermostats are highly sensitive and may require calibration. Recommended temperature calibration is “0.0°C”. The device has heating and cooling modes that can be switched easily. A low battery warning appears when the battery is low, indicating it's time for replacement. The receiver must be installed at least 50 cm away from the heating/cooling unit. The room thermostat should be placed in a frequently used room, avoiding areas with direct sunlight or near heating/cooling units. Operations within the heating/cooling unit must be carried out by qualified persons. The room thermostat has a key lock function to prevent unintended contact.
  • Page 2: WARRANTY CONDITIONS The warranty period starts from the invoice date and is warranted against manufacturing defects for 5 years. Devices and apparatus are delivered to the customer in working condition. On-site commissioning is subject to a service fee. The repair of the devices and apparatus covered by the warranty is carried out in our company factory. The maintenance of devices and apparatus is done in our company, and the round travel fares belong to the customer. In case of malfunctioning of the devices and apparatus whose warranty period continues, it is tested in our company whether the malfunction is caused by a customer or manufacturer fault. Customers should be aware of damages of the product and warn the manufacturer since the day warranty duration starts. Malfunctions resulting from the use of devices and apparatus contrary to the matters stated in the User Manual are not covered by the warranty. Devices and their apparatus are out of warranty if they are beaten, broken, or scratched by the customer. Your Room Thermostat works with the TPI algorithm, predicting when the temperature of your home will rise above or below the set temperature. TPI technology is designed to ensure that you get the best possible energy efficiency from your heating/cooling system.