ScreenIndicators
DAY AND HOUR SETTINGS
Thermostatto thebackand squeezeittowards theback.
Low Battery Warning: When the “ ” icon appears on the screen, it means
“low battery warning”. It is recommended to replace the batteries when this
warning appears.
ENGLISH
While your Room Thermostat is on, keep pressing ''Settings'' button for 3
seconds.
1
2
3
4
10
11
At the first screen that appears ''Hour'' part will be blinking. You may set
thetimewith“Up” and “Down”buttons.
DIGITAL ROOM THERMOSTAT
12
Warning: When the product is not used for a long period (more than 15 days),
remove the batteries. Otherwise, malfunctions that may occur would be out of
warranty.
After setting the time, ''Settings'' button needs to be pressed once. For
minute setting, minute part will be blinking. You may set the minute with
“Up” and “Down”buttons.
5
generallife.com.tr
6
7
8
9
Please throwyour dead batteries into thewaste bin forbatteries.
After setting the minute, ''Settings'' button needs to be pressed once to set
thedayof theweek.
ROOM THERMOSTAT WIRING DIAGRAM
THERMA 300S USER MANUAL
Mondayhas setasthefirstdayof theweekand indicated withnumber “1".
Numbers indicates the following days respectively 2-Tuesday, 3-
Wednesday, 4-Thursday, 5-Friday, 6-Saturdayand 7-Sunday
When setting is done you may exit by pressing for 3 seconds to “Settings”
button.
HEATING/COOLING UNIT
GENERAL SPECIFICATIONS
1
2
3
4
5
6
7
8
9
Day Indicator
Hours of Day
THERMA 300S is a wired room thermostat. The user can adjust the room
temperature with the required temperature and get more comfortable and
economicheating/cooling.
Hour Indicator
Screen Lock
Dailyand WeeklyProgram (7x24)
MODE SETTTINGS
Room Temperature
Set Temperature
Economy Mode
Comfort Mode
Programming Mode
Cooling Indicator
MODES
Different Mode Options (Comfort Mode and Economy Mode)
PreciseTemperatureMeasurement
Heating Calibration
ON/OFFControl
Wired Connection
TPIAlgorithm
NO COM
WEEKLY
PROGRAM
MODE
READY MODES
MANUAL MODE
Heating/Cooling Modes
THERMA 300S AND EQUIPMENTS
Warning!
Operations within the heating / cooling unit or the electrical installation
must be carriedout byprofessionally qualified persons.
- If the Cooling Indicator is blinking, the cooling
unit is working.
Comfort
Mode
Economy
Mode
Alkaline
Battery
Dowels and Screws
10
THERMA 300S
Room Thermostat
- If the Cooling Indicator is steady, the cooling unit
is not working.
Heating Indicator
Your Room Thermostat has 4 different modes. Two of them(Comfort and
Economy Mode) are preset modes. Other modes are manual mode and
programming mode.
ROOM THERMOSTATTEMPERATURE CALIBRATION
Temperature sensors which are used in Room Thermostats are highly
sensitive. You mayneed to calibrate yourRoom Thermostat if youwould like
to get the same temperature values with other thermometers in your living
space.
- If the Heating Indicator is blinking, the heating
unit is working.
In preset modes, temperature values are based on user's choices which has
been set in the beginning. Manual mode provides to operate the Room
Thermostat with temperature which user's required and set directly.
Programming mode continues to work according to the weekly program
determined bytheuser.
11
12
- If the Heating Indicator is steady, the heating
unit is not working.
Battery Indicator
While your device is turned off, press and hold the "On/Off"button for 3
seconds.
TECHNICAL DATA
Temperaturevaluesof presetmodes can be changed on “Settings” menu.
Press the "On/Off" button until the “
” menu appers. In order to see the
ROOM THERMOSTAT PLACEMENT
Dimensions
Operating Current
Relay NO Switching Current
100mm / 160mm / 18.2mm
In order to go to “Settings” menu, “Settings” button needs to be pressed
for 3 seconds. Date and time settings would appear in first screen, to skip
it“Settings” button should be pressed for 3 times.
desired temperature, set the temperature difference by press the
“Temperature Adjustment Buttons”. This value can be arranged between
“-8oC" and “+8oC".
3V DC (2 x AAA alkaline battery)
2A (30VDC – Resistive load)
0.5A (125VAC – Resistive load)
Room Thermostat needs to be placed in the room which is used most
frequently. For instance; living room or lounge. Placing the Room
Thermostat in a spot that have air circulation like entrance of a room or side
of window should be avoided. Also anywhere close to heating/cooling units
such as radiator, stove and spots which get direct sun lights would not be
suitable. Room Thermostat needs to be located above the floor 150 cm
height. Fewtrialsmaybe made to find themost convenientspot.
Comfort Mode's “
” temperature value would appear and temperature
Temperature Measurement Accuracy 0.1oC
To save the settings and exit, press the "On/Off" button until the device
turns off.
for Comfort Mode can be adjusted bypressing “Up” and “Down”buttons.
When setting is done, by pressing “Settings” button, Economy mode can
be set.
Operating Temperature Range
Battery Life
(5oC) – (30oC)
Note:Recommended tempreturecalibration is “0.0oC”.
1 Year (2 x AAA)
(-10oC) – (+50oC)
(-20oC) – (+60oC)
Operating Temperature
Storage Temperature
Economy Mode's “
” temperature value would appear and temperature
ROOM THERMOSTAT HEATING / COOLING MODES
Your Room Thermostat has heating and cooling modes. In order to switch
easilybetweenheating and cooling modes:
for Economy Mode can be adjusted bypressing “Up” and “Down”buttons.
Pressing “Settings” button for 3 seconds again would close “Settings”
screen.
While your device is turned off, press and hold the “On/Off” button for 3
seconds.
Manual mode temperature can be set by pressing “Up” and “Down”
buttons while on home screen. When “Up” or “Down” buttons are pressed
Room Thermostatwill be seton Manual Mode.
Pressthe“On / Off” button until the “
” menu appears.
ROOM THERMOSTAT
Buttons Functions
You can switch between “
” (heating) and “ ” (cooling) modes by
Youcanpressthe"Mode" buttontoswitchtoothermodes.
using the“Up” or "Down"buttons in the“
” menu.
To save the settings and exit, press the “On / Off” button or wait 10
seconds until thedeviceturns off.
PROGRAMMING MODE
You may choose which mode will be active, individually for each hour of the
day with programming mode. Weekly program mode includes 2 active
1
2
3
The settings you have made have been saved. Once you turned on your
device, itwill operatewiththe changed settings.
modes. Those areComfort Mode “
” and Economy Mode “
”.
In order to arrange the weekly program ''Programming” button needs to be
FACTORY SETTINGS RESET
pressed for 3 seconds.
4
5
6
You can reset your Room Thermostat to its default factory settings. This
operation resets the mode temperature values, calibration setting and
heating/coling modes to factory setting. To reset your Room Thermostat to
factory setting:
On the screen there will be icons for the day which wants to be
programmed, hours of thedayand activemode.
“By pressing “Mode” button, chosen mode for that specific hour may be
changed.
BATTERY PLACEMENT
Before starting, power off the device connected to the Room Thermostat
and make surethattheenergy is cut off.
While your device is turned off, press and hold the "On/Off"button for 3
seconds.
By pressing the up or down button, you can scroll through the hours of the
dayand program according to the activemode.
Press the “Setting” button to change the day of the week while making a
weeklyprogram.
1
2
3
4
5
6
On/Off Button
Pressthe“On/Off” button until “
While in the “ ” menu, select the “
buttons and pressthe“On/Off” button.
Your devicewill be turned off and resetto factory settings.
” menu appears.
Temperature Adjustment (To Increase)
Temperature Adjustment (To Decrease)
Weekly Program Button
” option by using “Up” or “Down”
After setting a weekly program press the ''Programming'' button for 3
seconds to saveit.
Setting Button
Mode Button – Unlock Button
KEY LOCK
In the Room Thermostatthereis akeylock function to avoidany unintended
contact.
As shown in the picture above, press the screwdriverforward from the space
shown, bend the tabs and separate the front cover. Insert 2 new AAA alkaline
batteries in the battery housing with the correct battery direction. Replace
both batteriesatthesametime. Then align thefront part of yourRoom
In order to unlock the Room Thermostat's key lock “Mode” button should be
pressed for 3 seconds. If buttons on Room Thermostat are not touched for
10seconds, keylock will be reactivated.
1
2
3
4
| General | Details |
|---|---|
| Name | GENERAL LIFE Therma 300S Wired Room Thermostat User Manual |
| Make | GENERAL LIFE |
| Language | English |
| Filetype | PDF (Download) |
| File size | 2.12 MB |

GENERAL LIFE HT330S RF Room Thermostat User Manual

GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual

GENERAL LIFE HT250 RF Digital Room Thermostat User Manual

GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual

GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual

GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual

GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual

GENERAL LIFE HT220S RF Digital Room Thermostat User Manual

GENERAL LIFE 270S RF Room Thermostat User Manual

GENERAL LIFE 270 Wireless Room Thermostat User Manual

GENERAL LIFE Therma 300S Wired Room Thermostat User Manual Overview
Summary of Contents
- Page 1: Day and hour settings are crucial for proper thermostat operation. Low battery warning indicates the need for battery replacement. Pressing the settings button for 3 seconds allows access to time settings. The first screen shows the hour part blinking for time adjustment. After setting the time, the settings button must be pressed again for minute adjustments. The room thermostat is a wired device that allows temperature adjustments for comfort and efficiency. Different mode options include comfort mode and economy mode. The thermostat has heating and cooling modes, which can be switched easily. Temperature calibration may be necessary for accurate readings. Weekly programming allows for individualized settings for each hour of the day.
- Page 2: TPI room thermostat working logic Your room thermostat works with the TPI algorithm, predicting temperature changes to maintain your set temperature with minimal deviation. If the placement of the TPI room thermostats is changed, the learning process will restart and should be considered as 7 days. The warranty period starts from the invoice date and covers manufacturing defects for 5 years. Devices and apparatus are delivered in working condition, and on-site commissioning is subject to a service fee. In case of malfunctioning devices under warranty, the cause will be tested and reported by the company. The connection between your room thermostat and the heating/cooling unit should be made by professionally qualified persons. TPI technology ensures energy efficiency by measuring and applying optimal timings for maintaining the desired temperature. Malfunctions caused by customer misuse are not covered by the warranty. The warranty document must be kept by the customer during the warranty period; a second document will not be issued if lost. The manufacturer is not responsible for compliance with directives if changes are made to the product without approval.