Room  
Temperature  
ROOM THERMOSTAT PLACEMENT  
ROOM THERMOSTAT HYSTERESIS NEGATIVE MENU  
The hysteresis negative factory setting of your Room Thermostat is  
-0.5°C. This value can be adjusted between “-0.1°C” and “-2.0°C”.  
While the hysteresis negative value is -0.5°C, your Room Thermostat  
will send a command to your heating unit when the room temperature  
drops 0.5°C below the set temperature. For example, when we set the  
Room Thermostat to 22.0°C, your heating unit will work when the  
room temperature drops to 21.5°C. To change the hysteresis negative  
setting  
ENGLISH  
Place your Room Thermostat in a room you use frequently in your  
living space. For example; like the hall or living room of your home.  
Avoid installing the Room Thermostat in places where there is a lot of  
air circulation, such as at the doorway or by the window. Also, do not  
place it close to heating units (heater core, fireplace, etc.) and in direct  
sunlight. We recommend that the room thermostat is placed at a  
height of 150cmfrom the floor.  
22.5oC  
22.0oC  
21.5oC  
Set  
Temperature  
UNDERFLOOR HEATING THERMOSTAT  
Heating  
Unit On  
generallife.com.tr  
SERIES:  
MITRA, ARUNA, CERES, GAIA, ILLONA, NORA, SENNA, THERMA  
Heating  
Unit Off  
Time  
min. 20 cm  
:While yourdeviceis off, press and hold the button for 3 seconds.  
FH25/FH25S USER MANUAL  
Pressthe button until the “  
In the hysteresis negative menu, you can adjust the operating  
sensitivitybyturning the button to the right or left.  
” menu appears.  
CoolingMode  
As soon as you energize your Room Thermostat, it will start working.  
Your room thermostat takes the average room temperature of last 40  
seconds as basis. If the ambient temperature rises above the  
hysteresis positive temperature you set, your Room Thermostat will  
start the cooling unit and if it drops below hysteresis negative  
temperature value, will stop the cooling unit. Thus, it is ensured that  
theambient temperatureremains within acertain range.  
GENERAL SPECIFICATIONS  
FH25/FH25S is a digital room thermostat designed for underfloor  
heating and cooling system. The user can get more comfortable and  
economic heating/cooling by adjusting the room thermostat with the  
required temperature.  
Press the button until the device turns off to save the settings and  
exit.  
The settings you have made have been saved. When you turn on  
yourdevice, itwillworkwiththeoperating sensitivityyouhaveset.  
SensitiveTemperatureMeasurement  
Temperature Calibration  
Hysteresis Adjustment  
ROOM THERMOSTATTEMPERATURE CALIBRATION  
ON/OFFControl  
Temperature sensors used in Room Thermostats are very sensitive.  
Based on the temperature on the thermometers in your living space  
youneed to calibrateyourRoom Thermostat. For this:  
FLOOR SENSOR TEMPERATURE SETTING MENU  
Wired connection  
If a floor sensor is installed with Room Thermostat, only GENERAL  
Life floor sensor should be installed. Otherwise, the product will be  
out of warranty.  
*Externaloor sensor is deactivatedin thecooling mode.  
Floor sensor temperaturesetting  
Heating/Cooling Modes  
Room  
Temperature  
While yourdeviceis off, pressand hold thebutton for 3 seconds.  
Press the button until you see the calibration menu that says “  
22.5oC  
*Incaseof floor sensor connected, the following settingsapply.  
The factory temperature setting for floor sensor is 28°C. This value  
can be adjusted between 23°C and 34°C. The floor sensor operating  
sensitivity is 1°C. For example, when you set the floor sensor  
temperature to 28°C, your Room Thermostat will stop the heating unit  
from working when the floor temperature rises to 29°C. When the floor  
temperature drops to 27°C, it starts the heating unit of the Room  
Thermostat. To change the floor sensor temperature:  
FH25/FH25S AND EQUIPMENTS  
Room Thermostat  
22.0oC  
Set  
Temperature  
press it. The temperature difference you want from the calibration  
menu, Adjust by turning the button to the right or left. This value can  
be adjusted between “-8°C” and “+8°C”.  
Dowels and  
Screws  
21.5oC  
Cooling  
Unit On  
Press the button until the device turns off to save the settings and  
exit.  
Note:Recommended temperaturecalibration settingis “0.0oC”.  
Cooling  
Unit Off  
Time  
ROOM THERMOSTAT HEATING / COOLING MODES  
Your Room Thermostat has heating and cooling modes. In order to  
switcheasilybetweenheating and cooling modes:  
While your device is turned off, press and hold the button for 3  
seconds.  
Press and hold thebutton for 3 seconds while yourdeviceis off.  
TECHNICAL DATA  
Press thebutton until the “  
” menu appears.  
Dimensions ( H / L / W )  
Operating Current  
Relay NO Switching Current  
85.7mm / 85.7mm / 33.5mm  
230V AC  
7A (240VAC – Resistive load)  
10A (120VAC – Resistive load)  
0.1oC  
Adjust the operating temperature by turning the “  
” button to the  
right or leftin theoor sensor temperaturemenu thatappears.  
Press the button until the device turns off to save the settings and  
exit.  
Pressthe button until the“  
” menu appears.  
” (heating) and “  
Temperature Measurement  
Accuracy  
Operating Sensitivity  
Operating Temperature Range  
Operating Temperature  
Storage Temperature  
You can switch between “  
” (cooling) modes  
” menu.  
The settings you have made have been saved. When you turn on  
your device, it will operate at the floor sensor temperature you have  
set.  
(-2.0oC) – (+2.0oC)  
(5oC) – (30oC)  
byturning the button to right or leftin the“  
To save the settings and exit, press the button until the device turns  
off.  
(-10oC) – (+50oC)  
(-20oC) – (+60oC)  
The settings you have made have been saved. Once you turned on  
yourdevice, itwilloperatewiththe changed settings.  
FACTORY RESET  
You can reset the Room Thermostat to its factory default settings.  
This action resets the calibration setting and hysteresis settings to  
the factory setting. To factory resetyourRoom Thermostat:  
While yourdeviceis off, press and hold the button for 3 seconds.  
ROOM THERMOSTAT  
ROOM THERMOSTAT HYSTERESIS POSITIVE MENU  
The hysteresis positive factory setting of your Room Thermostat is  
0.5°C. This value can be adjusted between “0.1°C” and “2.0°C”. While  
the hysteresis positive value is 0.5°C, your Room Thermostat will  
send a command to your heating unit when the room temperature  
rises 0.5°C above the set temperature. For example, when we set the  
Room Thermostat to 22.0°C, your heating unit will stop when the  
room temperature rises to 22.5°C. To change the hysteresis positive  
setting:  
1
2
Press thebutton until the “  
While in the “ ” menu, turn the button to the right or left, select the  
” option and pressthe button.  
” menu appears.  
3
4
5
Your devicewillturn off and resetto factory settings.  
ROOM THERMOSTAT WORKING PRINCIPLE  
HeatingMode  
1
2
3
Room Temperature  
Underfloor Heating Temperature*  
Set Temperature  
Heating Indicator  
- If the Heating Indicator is blinking, the heating unit is  
As soon as you energize your Room Thermostat, it will start working.  
Your room thermostat takes the average room temperature of last 40  
seconds as basis. If the ambient temperature rises above the  
hysteresis positivetemperature youset, yourRoom Thermostat turns  
off the heating unit, and if it drops below hysteresis negative  
temperature value, it turns on the heating unit. Thus, it is ensured that  
the ambient temperatureremains within acertain range.  
If the floor sensor measures temperature above 28°C, it turns off the  
heating unit.*  
While yourdeviceis off, pressand hold thebutton for 3 seconds.  
“Pressthebutton until the“  
In the hysteresis positive menu, you can adjust the operating  
sensitivitybyturning the “ ” button to the right or left.  
” menu appears.  
4
5
working.  
- If the Heating Indicator lights up constantly, the heating  
unit is not working.  
Cooling Indicator  
- If the Cooling Indicator is blinking, the cooling unit is  
working.  
Press the button until the device turns off to save the settings and  
exit.  
The settings you have made have been saved. When you turn on  
yourdevice, itwillworkwiththeoperating sensitivityyouhaveset.  
*Externaloor sensor is only activewhen itis connected.  
- If the Cooling Indicator is steady, the cooling unit is not  
working.  
*Externaloor sensor is only activewhen itis connected.  
1
2
3
4
GeneralDetails
NameGENERAL ARUNA FH25S Underfloor Heating Thermostat User Manual
MakeGENERAL
LanguageEnglish
FiletypePDF (Download)
File size1.98 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
GENERAL ARUNA 300S Smart Room Thermostat User Manual
GENERAL ARUNA 300S Smart Room Thermostat User Manual
GENERAL HT250S Digital Room Thermostat User Manual
GENERAL HT250S Digital Room Thermostat User Manual
GENERAL FH260S Underfloor Heating Thermostat User Manual
GENERAL FH260S Underfloor Heating Thermostat User Manual
GENERAL HT100S Digital Room Thermostat User Manual
GENERAL HT100S Digital Room Thermostat User Manual
GENERAL SOLARA 330S SMART Smart Room Thermostat User Manual
GENERAL SOLARA 330S SMART Smart Room Thermostat User Manual
GENERAL HT250 Digital Room Thermostat User Manual
GENERAL HT250 Digital Room Thermostat User Manual
GENERAL SENNA 300 Digital Room Thermostat User Manual
GENERAL SENNA 300 Digital Room Thermostat User Manual
GENERAL ARUNA 300S RF Digital Room Thermostat User Manual
GENERAL ARUNA 300S RF Digital Room Thermostat User Manual
GENERAL SENNA 300 Smart Room Thermostat User Manual
GENERAL SENNA 300 Smart Room Thermostat User Manual
GENERAL MITRA 250S Digital Room Thermostat User Manual
GENERAL MITRA 250S Digital Room Thermostat User Manual

GENERAL ARUNA FH25S Underfloor Heating Thermostat User Manual
Get the free PDF manual for the GENERAL ARUNA FH25S Underfloor Heating Thermostat User Manual and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

GENERAL ARUNA FH25S Underfloor Heating Thermostat User Manual Overview

Summary of Contents

  • Page 1: Room thermostat placement is important for accurate temperature readings. The hysteresis negative factory setting is -0.5°C, adjustable between -0.1°C and -2.0°C. The room thermostat will activate heating when the temperature drops 0.5°C below the set temperature. It is recommended to place the thermostat at a height of 150 cm from the floor and away from air circulation areas. The device takes the average room temperature of the last 40 seconds as a basis for operation. The factory temperature setting for the floor sensor is 28°C, adjustable between 23°C and 34°C. The room thermostat has heating and cooling modes that can be switched easily. Calibration of the room thermostat is necessary based on the temperature readings in your living space. You can reset the room thermostat to its factory default settings if needed. The hysteresis positive factory setting is 0.5°C, adjustable between 0.1°C and 2.0°C.
  • Page 2: Warranty conditions state that the warranty period starts from the invoice date and covers manufacturing defects for 2 years. Devices are delivered in working condition, and on-site commissioning is subject to a service fee. Repairs covered by the warranty are carried out at the company's factory, with transportation costs borne by the customer. Maintenance of devices is also conducted at the company, with travel fares belonging to the customer. Malfunctions are tested to determine if they are caused by customer or manufacturer faults, with a report issued by the company. If manufacturer-induced errors are detected, the customer can request a replacement or repair at the manufacturer's expense. If faults are caused by the customer, all expenses will be the customer's responsibility. Customers must report any damages to the manufacturer within the warranty period to maintain their rights. Malfunctions resulting from improper use are not covered by the warranty. Devices are out of warranty if damaged by the customer or if used with other brands without manufacturer approval.