Home > Honeywell > Honeywell TH5000 Series FocusPRO Non-Programmable Digital Thermostat Installation Guide
Honeywell TH5000 Series FocusPRO Non-Programmable Digital Thermostat Installation Guide
Installation
Guide
TM
FocusPRO TH5000 Series
Non-Programmable Digital Thermostat
This manual covers the following models
• TH5110D: For 1 Heat/1 Cool systems
• TH5220D: For up to 2 Heat/2 Cool systems
• TH5320U: For up to 3 Heat/2 Cool systems
(Remove battery holder to find model number)
• Heat only — two-wire systems,
three-wire zone valves (Series
20), and normally open zone
valves
System Types
• Gas, oil, or electric heat with air
conditioning
• Warm air, hot water, high-
efficiency furnaces, heat pumps,
steam, gravity
• Heat only with fan
• Cool only
• 750 mV heating systems
Must be installed by a trained, experienced technician
Read these instructions carefully. Failure to follow these instructions
can damage the product or cause a hazardous condition.
Need Help?
For assistance with this product please visit http://yourhome.honeywell.com
or call Honeywell Customer Care toll-free at 1-800-468-1502
® U.S. Registered Trademark. Patents pending.
Copyright © 2006 Honeywell International Inc.
All rights reserved.
69-1922ES
| General | Details |
|---|---|
| Name | Honeywell TH5000 Series FocusPRO Non-Programmable Digital Thermostat Installation Guide |
| Make | Honeywell |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.53 MB |

Honeywell T6 Pro Programmable Thermostat User Manual

Honeywell D1-528 Direct Thermostat Installation Guide

Honeywell FocusPRO P200 Programmable Thermostat User Guide

Honeywell RCHT8610WF Series Smart Thermostat Installation Guide

Honeywell T9 Smart Thermostat Installation Guide

Honeywell TH2320WF4011 FocusPRO Smart S200 Series Thermostat User Guide

Honeywell TL116A Thermostat Installation Guide

T10 Pro Smart Thermostat with Redlink Room Sensor

Honeywell TH6320WF2003 Lyric T6 Pro Wi-Fi Programmable Thermostat User Guide

Honeywell RTH9580 Wi-Fi Color Touchscreen Programmable Thermostat User Guide

Honeywell TH5000 Series FocusPRO Non-Programmable Digital Thermostat Installation Guide Overview
Summary of Contents
- Page 1: Installation guide for the FocusPRO TH5000 series non-programmable digital thermostat. This manual covers the following models: TH5110D for 1 Heat/1 Cool systems, TH5220D for up to 2 Heat/2 Cool systems, and TH5320U for up to 3 Heat/2 Cool systems. System types include gas, oil, or electric heat with air conditioning, warm air, hot water, high-efficiency furnaces, heat pumps, steam, gravity, heat only with fan, cool only, and 750 mV heating systems. Must be installed by a trained, experienced technician. Read these instructions carefully. Failure to follow these instructions can damage the product or cause a hazardous condition.
- Page 2: Installation guide Wallplate installation Separate wallplate from thermostat. Mount wallplate as shown below. It's easier to grasp the wallplate and remove it after completely removing the battery holder. Drill 3/16 holes for drywall. Drill 7/32 holes for plaster. CAUTION: Electrical hazard can cause electrical shock or equipment damage. Disconnect power before beginning installation. MERCURY NOTICE: If this product is replacing a control that contains mercury in a sealed tube, do not place the old control in the trash.
- Page 3: FocusPRO TH5110 / TH5220 / TH5320 Power options Keep wires in the shaded area. Remove factory-installed jumper only for two-transformer systems. Insert batteries for primary or backup power. Connect C for primary AC power (optional if batteries are installed). Wiring Terminal designations Shaded areas below apply only to TH5320U/TH5220D or as otherwise noted. Conventional Terminals: Heat Pump Terminals: Auxiliary heat relay* Emergency heat relay* *Aux and E terminals combined on TH5320U only.
- Page 4: Installation guide Wiring guide — conventional systems Shaded areas below apply only to TH5320U/TH5220D or as otherwise noted. 1H/1C system (1 transformer) Heat-only system with fan Cool-only system 2H/2C system (1 transformer) Heat-only system (normally open zone valve) 2H/2C system (2 transformers) Wire specifications: Use 18- to 22-gauge thermostat wire. Provide disconnect means and overload protection as required.
- Page 5: FocusPRO TH5110 / TH5220 / TH5320 Wiring guide — heat pump systems Shaded areas below apply only to TH5320U/TH5220D or as otherwise noted. 1H/1C Heat Pump System (TH5320U only) 2H/2C Heat Pump System 2H/1C Heat Pump System (TH5220D only) 3H/2C Heat Pump System (TH5320U only) Compressor contactor (stage 1) Compressor contactor (stage 2) Auxiliary heat relay Emergency heat relay Thermostat mounting instructions
- Page 6: Installation guide for configuring the thermostat to match the heating/cooling system. Press s or t to change settings and NEXT to advance to the next function. Press DONE to exit and save settings. Begin by pressing and holding the s and FAN buttons until the display changes. Setup function settings and options are provided, with factory defaults in bold. Different system types include various configurations for heat pumps and conventional systems. Changeover valve settings determine whether it is energized in cooling or heating. Fan control settings specify whether the thermostat or equipment controls the fan in heating. Cycle rates for heating systems vary based on efficiency and type of furnace. Emergency heat cycle rates are specified for different heating systems.
- Page 7: FocusPRO TH5110 / TH5220 / TH5320 Installer setup Settings & options (factory default in bold) Stage 1 compressor cycle rate (CPH) is recommended at 3 for most compressors. Stage 2 compressor cycle rate (CPH) is recommended at 3 for most compressors. Manual/Auto changeover options include manual changeover and auto changeover. Temperature display options include Fahrenheit and Celsius. Compressor protection includes a five-minute compressor off time. Auxiliary heat control has comfort and economy settings. Heat temperature range stops at a maximum of 90 °F (32 °C). Cool temperature range stops at a minimum of 50 °F (10 °C). System test instructions include pressing and holding specific buttons to begin testing.
- Page 8: Installation guide Auxiliary heat control (Setup Function 26): Comfort setting: The thermostat will prioritize comfort over economy depending on heat pump performance, load conditions, and whether the thermostat is calling for the heat pump. Economy setting: The thermostat will attempt to reach the temperature setting without activating the auxiliary heat. Accessories & replacement parts: Please contact your distributor to order replacement parts. Specifications Temperature ranges: Heat: 40° to 90°F (4.5° to 32°C), Cool: 50° to 99°F (10° to 37°C). Operating ambient temperature: 32° to 120°F (0° to 48.9°C). Shipping temperature: -20° to 120°F (-28.9° to 48.9°C). Operating relative humidity: 5% to 90% (non-condensing). Physical dimensions: TH5320U/TH5220D - 3-9/16 H x 5-13/16 W x 1-1/2 D. TH5110D - 3-7/16 H x 4-1/2 W x 1-5/16 D.
- Page 9: Guía de instalación TM Serie FocusPRO TH5000 Termostato digital no programable. Este manual incluye los siguientes modelos: TH5110D, TH5220D, TH5320U. Tipos de sistema: sólo calor, calefacción a gas, a aceite o eléctrico con aire acondicionado, sólo frío, calefacción de aire, agua caliente, sistemas de calefacción de alta efectividad. Debe ser instalado por un técnico capacitado y experimentado. Lea estas instrucciones atentamente. Si no sigue estas instrucciones, puede dañar el producto u ocasionar un riesgo.
- Page 10: Guía de instalación Instalación de la placa para pared Quite la placa para pared del termostato. Es más fácil quitar la placa para pared una vez que se extrae completamente el soporte de la batería. Monte la placa para pared como muestra la ilustración de abajo. En tablarroca, realice agujeros de 3/16. En yeso, realice agujeros de 7/3. PRECAUCIÓN: riesgo eléctrico. Puede ocasionar descargas eléctricas o dañar el equipo. Desconéctelo de la fuente de energía antes de comenzar la instalación. AVISO SOBRE EL MERCURIO. En caso de que este producto reemplace a un control que contenga mercurio en tubo sellado, evite arrojar el viejo control a la basura.
- Page 11: FocusPRO TH5110 / TH5220 / TH5320 Opciones de fuentes de energía Mantenga los cables en esta área sombreada. Quite el puente instalado en la fábrica sólo en los sistemas con dos transformadores. Coloque las baterías para suministro de energía principal o de respaldo. Conecte C para suministrar corriente CA (opcional si las baterías están instaladas). Designación de terminales. Las áreas sombreadas que aparecen abajo sólo se utilizan para los modelos TH5320U y TH5220D o según se indique. Terminales convencionales. Terminales de la bomba de calor. Para los sistemas de 2 transformadores, utilice cables comunes desde el transformador de la refrigeración.
- Page 12: Guía de instalación Cableado Guía de cableado: sistemas convencionales Las áreas sombreadas que aparecen abajo sólo se utilizan en el caso de los modelos TH5320U y TH5220D o según se indique. Sistema de 1 calentador y 1 refrigerador (1 transformador) Sistema de calefacción únicamente con ventilador Sistema de 2 calentadores y dos refrigeradores (1 transformador) Sistema de calefacción únicamente (Serie 20) Sistema de 2 calentadores y dos refrigeradores (2 transformadores) Especificaciones del cable Durante la configuración de instalación, coloque el tipo de sistema en Bomba de calor de 2 calentadores y 1 refrigerador.
- Page 13: FocusPRO TH5110 / TH5220 / TH5320 Guía de cableado: sistemas de bomba de calor Las áreas sombreadas que aparecen abajo sólo se utilizan para los modelos TH5320U y TH5220D o según se indique. Sistema de bomba de calor de 1 calentador y 1 refrigerador Sistema de bomba de calor de 2 calentadores y 2 refrigeradores Interruptor automático del compresor 24 V CA Válvula inversora Relé del ventilador (únicamente TH5320U) Cuando se fija en Em. Heat, envía un flujo de aire caliente Montaje del termostato Alinee las 4 lengüetas de la placa de pared con las ranuras de la parte posterior del termostato y presione levemente hasta que el termostato encaje en su lugar.
- Page 14: Guía de instalación Siga el procedimiento que aparece a continuación para configurar el termostato. Presione s o t para cambiar la configuración. Presione NEXT para avanzar a la siguiente función. Presione DONE para salir y guardar la configuración. Funciones de la configuración Configuraciones y opciones (las que vienen desde la fábrica aparecen en negrita). Las áreas sombreadas que aparecen abajo sólo se utilizan para los modelos TH5320U y TH5220D o según se indique. Tipo de sistema Válvula inversora (terminal O/B). Control del ventilador (calefacción). Velocidad del ciclo térmico de la primera etapa.
- Page 15: FocusPRO TH5110 / TH5220 / TH5320 Configuración de instalación Funciones de la configuración Configuraciones y opciones (las que vienen desde la fábrica aparecen en negrita) Rango de ciclos del compresor de la etapa 1 (CPH) recomendado para la mayoría de los compresores. Conversión manual/automática Visor de temperatura en Fahrenheit y Celsius Protección del compresor con tiempo de apagado de 5 minutos. Limitador de rango de temperatura del sistema de calefacción con configuración máxima de 90 °F (32 °C). Limitador de rango de temperatura del sistema de enfriamiento con configuración mínima de 50 °F (10 °C). Prueba del sistema y estado del sistema.
- Page 16: Guía de instalación Funciones especiales Control de calor auxiliar: Configuración comfort: El termostato priorizará el confort sobre la economía dependiendo del funcionamiento de la bomba de calor. Configuración económica: El termostato intentará alcanzar la temperatura de configuración sin activar el calentador auxiliar. Accesorios y piezas de repuesto: Póngase en contacto con su distribuidor para solicitar piezas de repuesto. Descripción de las piezas: Soporte de la batería, ensamblado de la placa de cubierta. Especificaciones: Rangos de temperatura y eléctricos. Temperatura ambiente de funcionamiento: 32 °F a 120 °F (0 ºC a 48,9 °C). Humedad relativa operativa: 5% a 90% (no condensable). Dimensiones físicas: Variaciones según el modelo. Soluciones para automatización y control.