Home > GENERAL LIFE > GENERAL LIFE HT25 Smart Room Thermostat User Manual

GENERAL LIFE HT25 Smart Room Thermostat User Manual

ROOM THERMOSTAT  
SMART RECEIVER SETUP  
Remove the battery cover located on the back of your Room Thermostat. Insert 2  
new AAA alkaline batteries into the battery housing with the correct battery  
directionand close thebattery cover. Replaceboth batteriesatthesametime.  
ENGLISH  
For smart receiversetup, download the application fromApp Storeor Google Play  
or scan the QR code below with your smartphone. In this way, you will be able to  
download the mobile application from App Store or Google Play to your  
3
Low Battery Warning: When the “  
” icon appears on the screen, it means “low  
SMART ROOM THERMOSTAT  
1
2
smartphone. (You may be required to have  
a
QR code reader application  
battery warning”. It is recommended to replace the batteries when this warning  
appears.  
depending on thebrand and model of yourphone, for this process.)  
4
5
6
generallife.com.tr  
Warning: When the product is not used for a long period (more than 15 days), remove  
thebatteries. Otherwise, malfunctions thatmay occurwouldbeoutof warranty.  
Pleasethrowyourdead batteries into thewastebin forbatteries.  
SERIES:  
Click to download.  
MITRA, ARUNA, CERES, GAIA, ILLONA, NORA, SENNA, THERMA  
7
RECEIVER PLACEMENT  
1
2
3
4
Room Temperature  
HT25 SMART/HT25S SMART/HT26S SMART USER MANUAL  
WHAT IS A SMART ROOM THERMOSTAT?  
The important things to note for the Receiver placement are  
avoiding physical contact between the receiver and the  
heating/cooling unit, and protectingitagainst materialssuch  
asliquid, dust, etc.  
Open Window Detection Feature  
Battery Indicator  
Set Temperature  
Complete the user registration process by opening the mobile application that  
youdownloaded.  
A
smart room thermostat is  
a
device that allows you to control your heating  
Heating Indicator  
Open theBluetooth fromyourmobile phone's settings.  
5
- If the Heating Indicator is blinking, the heating unit is working.  
- If the Heating Indicator is steady, the heating unit is not working.  
Cooling Indicator  
- If the Cooling Indicator is blinking, the cooling unit is working.  
- If the Cooling Indicator is steady, the cooling unit is not working.  
ON/OFF and Temperature Setting Button  
equipment viaAPPwiththeinternetevenwhen youarenot athome.  
After you completed the user registration process, press the “+” button in the top-  
right corner of the main screen of the application, Press the receiver's Wi-Fi  
pairing button for 5 seconds.  
The devices should be placed to minimize the damage to the received and  
transmittedsignals bypayingattentiontothefollowingpoints;  
HOW DOES HT25 SMART/HT25S SMART/HT26S SMART WORK?  
6
7
HT25 SMART/HT25S SMART/HT26S SMART is a smart wireless room thermostat.  
You can control it with the mobile application after you pair your room thermostat  
withthereceiver, andcompletetheinstallationofthesmartreceiver.  
COM  
NO  
The LEDon thereceiverwillstart to blink green.  
Setup will begin with Bluetooth in the application. When the device is found, press  
theAdd” button.  
Note: During active use of the room thermostat, the symbols indicated by 4, 5 and 6  
willnot appear on thescreen.  
Press the “+” button near the W Modem device and press the “Next” button after  
making surethatyouenteredthecorrectWi-Fiinformation.  
Wait until the setup process is completed. When you saw the green approval  
symbol on theW Modem, presstheDone” button in thetop-right corner.  
WHAT ARE THE ADVANTAGES OF THE HT25 SMART/HT25S SMART/HT26S  
SMART?  
MİN. 50 CM  
RECEIVER  
You can control your home's temperature via its mobile application, no matter  
whereyouarein theworld.  
1-Manual Operation Button:  
Deactivates the receiver and allows users to  
manually use the heating/cooling unit.  
2-Wi-Fi Pairing Button:  
1
2
3
You can easilycreatedaily and weeklyschedules viaitsmobile application.  
You can place the room thermostat anywhere in your home, thanks to its use with  
batteries.  
ROOM THERMOSTATTEMPERATURE CALIBRATION  
Temperature sensors which are used in room thermostats are highly sensitive. You  
may need to calibrate your room thermostat if you would like to get the same  
temperaturevaluesasother thermometersin yourliving space.  
ISITMA/SOĞUTMA ÜNİTESİ  
Makes the receiver ready for smart installation.  
3-Receiver LED Light  
4- Receiver Power Cable Input  
It ensures that your living space stays at the desired temperature at any time. In  
this way, you can saveup to 30% on your bills by preventingyour heating unit from  
working unnecessarily.  
The devicesshould not be mounted on metalsurfaces.  
The devices should not be installed close to electrical cables and electronic  
equipment such ascomputers and televisionunits.  
While yourdeviceis turned off, pressthebutton for 3 seconds.  
5- Heating/Cooling Unit Connection Cable Input  
Press the button until the “  
” menu appears. To see the desired temperature,  
The devices should not be installed near large metal structures or other building  
materialsusing finemetalmeshes such asspecialglass or specialconcrete.  
Distance between the room thermostat and the Receiver should not exceed 20  
metersor 2 floors.  
set the temperaturedifferencebyturning the button right or left. This valuecan be  
arranged between-8° C" and “+8°C".  
RULES THAT NEED TO BE OBSERVED FOR SAFETY  
1-Be sureto readtheuser manual beforeusing thedeviceand itsequipment.  
2-Opening, disassembly, or use of plastic parts of the product and equipment other  
than theintended purpose areout of warranty.  
To savethesettingsand exit, pressthebutton until thedeviceturns off.  
Note:Recommended temperaturecalibration is“0.0oC”.  
The receivermust be installed atleast50cmawayfromtheheating/cooling unit.  
4
5
3-Please make sure that the sockets to which you connect your devices and  
equipment areattherecommendedvoltagevaluein theuser manual.  
4-Keep away and protect your product and its equipment from all kinds of external  
substances such asliquid, dust, heat, etc.  
ROOM THERMOSTAT HEATING / COOLING MODES  
Your Room Thermostat has heating and cooling modes. In order to switch easily  
betweenheating and cooling modes:  
RECEIVER LED DESCRIPTIONS  
RECEIVER INSTALLATION  
First, shut down your heating/cooling unit and your heating/cooling unit's power  
sourcewithallelectricalcurrent(fuse, socket, etc.)  
Blinking Red  
The receiver did not get any signal from the  
heating/cooling unit for 22 minutes or longer and  
the heating/ cooling unit has shut down.  
Waiting for a pairing signal from the room thermostat.  
The receiver and the room thermostat have been paired.  
Smart installation has not been completed.  
The receiver is in Bluetooth searching mode.  
Smart installation has been completed.  
The heating/cooling unit is not working.  
The heating/cooling unit is working.  
While yourdeviceis turned off, pressand hold thebutton for 3 seconds.  
5-Do not expose the device cables to any jamming and pressure. Take care to  
connect thedevices'energyconnection to thesocketsyoucan alwaysreach.  
6-Turn off the electrical power to prevent damage to your device and apparatus in  
caseof lightning and thunderstorms.  
As shown in the connection diagram, connect one end of the heating/cooling unit  
connection cableto theCOMand theother to theNO input of thereceiver.  
Connect the other ends of the cable -which you connected to the receiver- to the  
room thermostat connection terminal as shown in your heating/cooling unit's  
user manual.  
Pressthebutton until the“  
You can switch between “  
thebutton to right or leftin the“  
” menu appears.  
” (heating) and “  
” menu.  
Fast Blinking Red  
Steady Red  
” (cooling) modes by turning  
To savethesettings and exit, pressthebutton until thedeviceturns off.  
The settings you have made have been saved. Once you turned on your device, it  
willoperatewiththechanged settings.  
7-Turn off theelectricalpower when yourdeviceis not used for along time.  
8-Your devices and equipment should be used by paying attention to the matters  
stated in the user manual. In case of damage and malfunctions, arising from  
improper use (contact with liquid, falling to the ground, etc.) definitely ask for the  
installer's help.  
Blinking Green  
Steady Green  
You must first connect the receiver power cable to the receiver and then to the  
fuse to which theheating/cooling unit is connected.  
Steady Turquoise  
After completing the cable connection process, first, turn on your fuse and then  
yourheating/cooling unit.  
ROOM THERMOSTAT HYSTERESIS POSITIVE MENU  
3 Short Red Blinking  
Shut the heating/cooling unit down signal has  
reached the receiver.  
The hysteresis positive factory setting of your room thermostat is 0.5°C. This value  
may be adjusted between “0.1°C” and “2.0°C”. While the hysteresis positive value is  
0.5°C, if the room temperature goes above 0.5°C of the set temperature, your room  
thermostat will send a signal to your heating/cooling unit. For instance, when you  
set your room thermostat to 22.0°C, if the room temperature goes above 22.5°C, on  
the heating mode your heating unit will stop working; on the cooling mode your  
cooling unit willstart working. To change thehysteresispositivesetting:  
9-Call our service for maintenance and repair of HT25 SMART/HT25S  
SMART/HT26S SMART and its equipment. Maintenance and repair of the device  
and equipment should be carried out only by the technical service of ISIPARK A.S.  
and its authorized services, spare parts, and accessories specified by the company  
should be used.  
Finish the installation of the room thermostat to pair the receiver with the room  
thermostat.  
3 Short Green Blinking Operate the heating/cooling unit signal has  
reached the receiver.  
Blinking Red and Green The heating/cooling unit is working in manual mode.  
AC  
RECEIVER WIRING DIAGRAM  
COM  
NO  
(230V)  
ROOM THERMOSTAT PLACEMENT  
The room thermostat needs to be placed in the room which is used most frequently.  
For instance; the living room or lounge. Placing the room thermostat in a spot that  
has air circulation like the entrance of a room or the side of the window should be  
avoided. Also anywhereclose to heating/cooling units such as a radiator, stove, and  
spots that get directsun lights would not be suitable. The room thermostat needs to  
be located abovethe floor 150 cm in height. Few trials may be made to find the most  
convenientspot.  
HT25 SMART/HT25S SMART/HT26S SMARTand EQUIPMENT  
Room Thermostat  
While yourdeviceis turned off, pressand hold thebutton for 3 seconds.  
Pressthebutton until the menu appears.  
Adjust the operating sensitivity by turning the button right or left in the “  
Holder  
Alkaline  
Battery  
Receiver  
Dowels and  
Screws  
hysteresis positive menu. To save the settings and exit, press the button until the  
deviceturns off.  
Changes have been saved. Your room thermostat will be working with set  
operating sensitivitywhen youopen yourdevice.  
HEATING/COOLING UNIT  
Warning!  
ROOM THERMOSTAT HYSTERESIS NEGATIVE MENU  
TECHNICAL DATA  
Room Thermostat  
Operations within the heating/cooling unit or the electrical installation must be  
carriedout byprofessionally qualified persons.  
The hysteresis negative factorysettingof your room thermostatis -0.5°C.This value  
may beadjustedbetween-0.1°Cand-2.0°C”.Whilethehysteresisnegativevalueis  
-0.5°C, if the room temperature goes below 0.5°C of the set temperature, your room  
thermostat will send a signal to your heating/cooling unit. For instance, when you  
set your room thermostatto 22°C, if the room temperature goesbelow21.5°C,on the  
heating mode your heating unit will start working; on the cooling mode your cooling  
unitwillstopworking.To changethehysteresisnegativesetting:  
Dimensions (H/L/W)  
Operating Current  
85.7mm / 85.7mm / 33.5mm  
3V DC (2 x AAA Alkaline Battery)  
PAIRING THE ROOM THERMOSTAT WITH THE RECEIVER  
Temperature Measurement Accuracy 0.1oC  
To pair the room thermostat with the receiver, press the “Manual Operation  
Button” and “Wi-Fi Pairing Button” together at the same time and see the  
receiver's fastblinking redLED.  
Operating Sensitivity  
Operating Temperature Range  
Battery Life  
Operating Temperature  
Storage Temperature  
(-2.0oC) – (+2.0oC)  
(5oC) – (40oC)  
BATTERY PLACEMENT  
1 Year (2 x AAA)  
(-10oC) – (+50oC)  
(-20oC) – (+60oC)  
Pressthebutton for 3 seconds while yourdeviceis turned off.  
While yourdeviceis turned off, pressand hold thebutton for 3 seconds.  
Pressthebutton until the menu appears.  
Adjust the operating sensitivity by turning the button right or left in the“  
Pressthebutton until “  
” thepairing menu appears.  
Turn yourroomthermostat's button while theLEDis fastblinking red.  
Ifthepairing is successful, thefastredashing LEDon thereceiverwillbe steady.  
The receiverand room thermostathavebeen pairedwitheachother.  
Receiver  
hysteresisnegative menu. To savethe settings and exit, press the button until the  
deviceturns off.  
Dimensions (H/L/W)  
Operating Current  
Relay NO Switching Current  
90mm / 90mm / 25mm  
230V AC  
7A (240VAC – Resistive Load)  
10A (120VAC – Resistive Load)  
(-20oC) – (+60oC)  
Changes have been saved. Your room thermostat will be working with set  
operating sensitivitywhen youopen yourdevice.  
Storage Temperature  
2
1
3
4
GeneralDetails
NameGENERAL LIFE HT25 Smart Room Thermostat User Manual
MakeGENERAL LIFE
LanguageEnglish
FiletypePDF (Download)
File size2.1 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
GENERAL LIFE HT330S RF Room Thermostat User Manual
GENERAL LIFE HT330S RF Room Thermostat User Manual
GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual
GENERAL LIFE HT250 RF Digital Room Thermostat User Manual
GENERAL LIFE HT250 RF Digital Room Thermostat User Manual
GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual
GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual
GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual
GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual
GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual
GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual
GENERAL LIFE HT220S RF Digital Room Thermostat User Manual
GENERAL LIFE HT220S RF Digital Room Thermostat User Manual
GENERAL LIFE 270S RF Room Thermostat User Manual
GENERAL LIFE 270S RF Room Thermostat User Manual
GENERAL LIFE 270 Wireless Room Thermostat User Manual
GENERAL LIFE 270 Wireless Room Thermostat User Manual

GENERAL LIFE HT25 Smart Room Thermostat User Manual
Get the free PDF manual for the GENERAL LIFE HT25 Smart Room Thermostat User Manual and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

GENERAL LIFE HT25 Smart Room Thermostat User Manual Overview

Summary of Contents

  • Page 1: Room thermostat setup involves removing the battery cover and inserting new AAA alkaline batteries. For smart receiver setup, download the application from App Store or Google Play. A low battery warning appears when the icon shows on the screen, indicating it's time to replace the batteries. When the product is not used for over 15 days, remove the batteries to avoid malfunctions. The receiver should be placed away from heating/cooling units and protected from liquids and dust. The smart room thermostat allows control of heating equipment via a mobile application. The heating indicator shows whether the heating unit is working or not. You can create daily and weekly schedules through the mobile application. The room thermostat should be placed in frequently used rooms, avoiding areas with direct sunlight or air circulation issues. The hysteresis positive factory setting of the room thermostat is 0.5°C, adjustable between 0.1°C and 2.0°C.
  • Page 2: Room temperature Open window detection feature The warranty period starts from the invoice date and is warranted against manufacturing defects for 2 years. If a window is left open, cold air will enter and the temperature in the room will drop rapidly. The open window detection feature allows the Room Thermostat to operate the heating/cooling system more efficiently. The Room Thermostat switches to alarm status if it detects a sudden drop in room temperature. The maintenance of devices and apparatus is done in our company. Malfunctions resulting from the use of devices contrary to the user manual are not covered by the warranty. The warranty document must be kept by the customer during the warranty period. The customer can make complaints and appeals to consumer courts or consumer arbitration committees. The product can be reset to its default factory settings.