Description of screen indicators  
a.  
b.  
ZigBee icon. The ZigBee icon will flash when the thermostat  
searches for networks andlights up when connected.  
Time. This is set automatically after a short time  
when connected to the Futurehome Smarthub.  
c.  
Home and Away mode.  
Heating on / off indicator. If the thermostat heats the floor,  
the lines will move to the right.If maximum guard is used  
the lines flash if the temperature limit is exceeded.  
d.  
e. Indicator flashes when open window is detected.  
f. Manual / Auto indicator.  
g. Indicates that the temperature is set.  
h. Indicator for active child lock / button lock.  
Futurehome Smart Termostart PR  
User Manual - EN  
On/Off button  
Inc. temp  
Lower temp  
Mode button  
Zigbee pairing  
Functions  
To control the thermostat remotely it must be added to a ZigBee gateway  
Button  
Short press  
Long press  
1 . Start the process of adding new devices to your ZigBee gateway  
and follow the instructions.  
Confirm/go back  
Temperature increase  
Temperature decrease  
Turn ON/OFF  
Enter menu  
2 . To put the thermostat in pairing mode: Long press '-' until the  
ZigBee icon flashes.  
3 . Continue the process of adding new devices to the app.  
Start ZigBee pairing  
Change between home  
and away mode  
Display date in MM/DD  
format  
Advanced settings  
Long press ‘  
Long press ‘  
’ and‘  
’ and‘  
’ : Open advanced settings  
’ : Lock/Unlock  
When the thermostat is on, press and hold ‘ + ’ and ‘ - ’  
(5s) simultaneously to open advanced settings.  
Max guard function:  
1 . Sensor type  
Menu 1 / 02 Max guard. Floor sensor must be installed. The thermostat will  
regulate according to the room sensor, but interrupt heating if the floor  
sensor exceeds the maximum guard temperature. Standard is 27°C. This  
setting can be changed under Menu 3.  
00: Air sensor / Internal 01: Floor sensor / External  
02: Max guard / regulator on  
air temperature and limiter with floor sensor  
2 . Floor sensor type / External:  
There is also a maximum guard when the thermostat is set to floor sensor.  
The thermostat regulates according to the floor sensor, but will interrupt  
heating if the floor sensor exceeds the maximum guard temperature.  
Standard is 27°C. This setting can be changed under Menu 3.  
0: 10 kOhm | 1: 12 kOhm | 2: 15 kOhm | 3: 47 kOhm  
3 . Max Guarding TemperatureThis must be set in the thermostat.  
20-95 ° C, Standard is 27 ° C, '-' No limit.  
4 . Turn: 1-9 ° C, Standard is 2 ° C  
To control the thermostat remotely it must be added to a ZigBee gateway  
5 . Calibration: -9 to + 9 ° C, Standard is 0 ° C  
6 . Highest set point: 35-90 ° C, Standard is 35 °C  
7 . Lowest setpoint: 0-30 ° C, Standard is 5 °C  
8 . Home mode setpoint: The standard is 22 ° C  
9 . Setpoint for away mode: The default is 15 ° C  
10. Brightness in sleep mode: 1-10, default is 1  
11. Open window detection: 0 = Disabled / 1 = Active  
1 . Start the process of adding new devices to your ZigBee gateway and  
follow the instructions.  
2 . To put the thermostat in pairing mode: Long press ‘  
’ until the  
ZigBee icon flashes  
3 .  
Continue the process of adding new devices to the app.  
Electrical data  
Power: 230 V / 50 Hz  
Circuit breaker: Max 16 A  
Maximum load: 3600 W  
1-pole electronic relay  
12. Restart the system:  
Press + or - to change '-' to '==' and waitfor 5s  
13. Reset to factory settings  
Press + or - to change '-' to '==' and waitfor 5s  
Internal power supply with galvanic isloation  
Do not use self-regulating heating cable  
Do not use for contactor control  
You can change settings with ‘ + ’ or ‘ - ’  
Press ‘ ’ to select the settings and proceed.  
Futurehome AS  
P.O Box 72, 0801 Oslo, Norway  
To save the changes and exit advanced settings,  
press ‘ ’ .  
GeneralDetails
NameFuturehome Co020, Co021 Smart Thermostat PR Owner’s Manual
MakeFuturehome
LanguageEnglish
FiletypePDF (Download)
File size0.14 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...

Futurehome Co020, Co021 Smart Thermostat PR Owner’s Manual
Get the free PDF manual for the Futurehome Co020, Co021 Smart Thermostat PR Owner’s Manual and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

Futurehome Co020, Co021 Smart Thermostat PR Owner’s Manual Overview

Summary of Contents

  • Page 1: Description of screen indicators ZigBee icon will flash when the thermostat searches for networks and lights up when connected. Time is set automatically after a short time when connected to the Futurehome Smarthub. Heating on/off indicator shows if the thermostat heats the floor. Indicator flashes when an open window is detected. Manual/Auto indicator is present. Indicates that the temperature is set. Indicator for active child lock/button lock. To control the thermostat remotely, it must be added to a ZigBee gateway. Max guard function regulates according to the room sensor but interrupts heating if the floor sensor exceeds the maximum guard temperature. Electrical data includes power specifications and maximum load details.