Home > Vaillant > Vaillant senso Comfort Thermostat Instructions

Vaillant senso Comfort Thermostat Instructions

Works with Vaillant’s  
heat pump range  
Heating  
Hot water  
Renewables  
sensoCOMFORT  
The sensoCOMFORT is Vaillant’s latest control for multi-zone heating systems. It’s been designed to be simple to install and use, and  
operates with Vaillant’s proprietary eBUS protocol. This ensures all the components of the system can easily communicate with each  
other to provide optimum system performance. It’s perfect for multi-zone gas-fuelled systems, and hybrid, or renewable installations.  
The sensoCOMFORT has been designed to be simple to install, with guided commissioning that detects all the components of  
a system and proposed pre-defined settings. The system will propose pre-defined settings to optimise your customers heating,  
simplifying commissioning and saving you time during installation.  
A simplified interface means that your customers will also find this control more intuitive to use. Time programs can be created in  
minutes by answering a few questions, and when used with the myVAILLANT connect gateway, the myVAILLANT app makes it easy  
to use on the go. The sensoCOMFORT also features an energy dashboard, which provides valuable insights into energy consumption  
over a two-year period. This data will include an overview on renewable gain when a Vaillant heat pump is fitted as part of the  
heating system.  
To provide a weather compensated solution, the sensoCOMFORT comes complete with an outdoor sensor that will automatically  
adjust the flow rate of the boiler for ultimate efficiency.  
The sensoCOMFORT is available in a wireless version (RF) that can control up to three heating zones. With the ability to cascade up  
to seven boilers, the sensoCOMFORT is perfect for the larger, commercial rig installations.  
GeneralDetails
NameVaillant senso Comfort Thermostat Instructions
MakeVaillant
LanguageEnglish
FiletypePDF (Download)
File size0.37 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
Vaillant VRC 700 Weather Compensating Thermostat Instruction Manual
Vaillant VRC 700 Weather Compensating Thermostat Instruction Manual
Vaillant VRT15 Room Thermostat User Guide
Vaillant VRT15 Room Thermostat User Guide
Vaillant VRC 700 Programmable Weather Compensating Thermostat Owner’s Manual
Vaillant VRC 700 Programmable Weather Compensating Thermostat Owner’s Manual
vaillant VR 92f/3 Wireless Additional Room Thermostat Instructions
vaillant VR 92f/3 Wireless Additional Room Thermostat Instructions
Vaillant VRT 51f sensoROOM Wireless Room Thermostat Instruction Manual
Vaillant VRT 51f sensoROOM Wireless Room Thermostat Instruction Manual

Vaillant senso Comfort Thermostat Instructions
Get the free PDF manual for the Vaillant senso Comfort Thermostat Instructions and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

Vaillant senso Comfort Thermostat Instructions Overview

Summary of Contents

  • Page 1: Works with Vaillant’s heat pump range. The sensoCOMFORT is Vaillant’s latest control for multi-zone heating systems. It operates with Vaillant’s proprietary eBUS protocol for optimum system performance. The system proposes pre-defined settings to optimize heating, simplifying commissioning. A simplified interface allows customers to create time programs quickly. The myVAILLANT app enhances usability on the go. The sensoCOMFORT features an energy dashboard for insights into energy consumption. It includes an outdoor sensor for weather compensation and efficiency. The wireless version can control up to three heating zones. It is suitable for larger commercial rig installations with the ability to cascade up to seven boilers.
  • Page 2: Features & benefits Boiler modulation ensures peak performance and optimum efficiency for a Vaillant heating system. Effortlessly set heating programmes using the time programme assistant. The sensoCOMFORT comes with an outdoor sensor that adjusts flow temperatures for optimal efficiency. The myVAILLANT app can be used to manage heating and hot water requirements on the go. The touch interface provides a simplistic method of navigating the control. The wired sensoCOMFORT can support up to 5 heating zones, while the wireless version can support up to 3. The energy dashboard provides enhanced insight into heating system performance and energy consumption. The sensoCOMFORT is available wired and wireless. Technical data includes article numbers and dimensions for various models. Adjustable temperature range is from 5 to 30 degrees Celsius.
  • Page 3: Control a combination boiler with one wired/wireless heating zone and control everything from a single programmable thermostat. Control a system or open vent boiler with one wired/wireless heating zone and hot water, and control everything from a single programmable thermostat. Control a combination, system or open vent boiler with two wired/wireless heating zones and hot water using programmable thermostats. Control a combination, system or open vent boiler with three wired/wireless heating zones using programmable thermostats. Add myVAILLANT connect for additional connectivity functions. sensoCOMFORT article numbers include 0010036819 and 0010036820. Wireless SensoCOMFORT RF article numbers include 0010036820 and VR 92f 0020260940. Wired and wireless system control options are available. Various model numbers are referenced, including VR 71 0020184847 and VR 92 0020260925. Programmable thermostats are essential for managing heating zones.
  • Page 4: Control a combination, system or open vent boiler with four wired heating zones and hot water using programmable thermostats. Control a combination, system or open vent boiler with five wired heating zones and hot water using programmable thermostats. System control. Upgrade any system by installing myVAILLANT connect. How to video. Heating. Hot water. Renewables. Note: items sold individually, these are suggestions for use. sensoCOMFORT.