SALUS Programmable Wired Thermostat VS30W/VS30B Installation Guide
VS30 thermostat in connection with a boiler with a “NO” voltage free
terminal through the RM-16A relay
Installation
Proper thermostat placement
The VS30 thermostat has been designed for flush mounting in
a standard electrical box with a diameter of 60 mm.
NSB function is not active.
AC 230V
1
2
3
L
M
M
T
NSB
OUTPUT
S1 S2
SL
L
N
NO
COM
NC
SL
OUTPUT
VS30
INPUT 230V AC
Note: Use the rear plate of the VS30 thermostat only with this model.
N
POWER SUPPLY
230V AC / 50 Hz
L
ual
Wiring diagrams
N
Button Functions
An additional temperature sensor
T
is optional.
Button Function
IMPORTER:
QL CONTROLS Sp. z o.o. Sp. k.
ul. Rolna 4, 43-262 Kobielice
PRODUCER:
Salus Limited
6/F, Building 20E, Phase 3, Hong Kong
Science Park, 20 Science Park East Avenue,
Shatin, New Territories, Hong Kong
VS30 thermostat in connection with actuator or pump
Time and date setting
Increasing / decreasing temperature or value
AC 230V
L
Note: During the first start-up, thermostat will automatically start time and date
setting - in this case go to step 4.
Selection of the operating mode, switching between values
T
Press any button to highlight the screen, then follow the steps below:
Short press - selection confirmation
Long press - entry to or exit from the menu
SALUS Controls is a member of the Computime Group
NSB
OUTPUT
S1 S2
SL
L
N
OR
M
1
2
Maintaining a policy of continuous product development SALUS Controls plc reserve the right to
change specification, design and materials of products listed in this brochure without prior notice.
+
Long press causes blocking or unlocking the thermostat
Long press enters the installer mode
VS30
+
+
Introduction
The VS30 thermostat controls temperatures of individual heating zone
in underfloor heating systems. Thermostat allows for significant savings
thanks to the possibility of maximum reduction the set temperature.
The full version of the manual in PDF format is available on the website
N
LCD Icon description
3 sek.
VS30 thermostat in connection with wiring centre
3
4
1
2
3
4
5
6
7
8
In this diagram, the VS30 thermostat manages the NSB function,
more details about NSB function can be found on the next page.
Product Compliance
This product complies with the following EU Directives: Electromagnetic
Compatibility 2014/30/EU, Low Voltage Directive 2014/35/EU and
RoHS 2011/65/EU. Full information is available on the website
9
20
19
10
11
VS35
VS30
Safety Information
Select the time format
or buttons.
to confirm the changes.
INPUT
NSB
OUTPUT
NSB
Use in accordance with national and EU regulations. Use the device only as
intended, keeping it in a dry condition. The product is for indoor use only.
Installation must be carried out by a qualified person in accordance with
national and EU regulations.
S1 S2
SL
L
N
S1 S2
SL
L
N
with
Press
18
17
16
15
12
13
14
T
T
5
6
L
L
N
N
SL
L
N SL
Terminals description
11. Current / set temperature
12. Program number
13. AM/PM
1.
Current active mode
KL08NSB
KL06
2. Comfort mode
3. Standard mode
4. Economic mode
5. Automatic mode
6. PARTY mode
Terminal
L,N
Description
14. Key lock
Power Supply 230 V AC
15. Day of the week
16. Settings
17. Time
18. Additional temp. sensor
19. Cooling
20. Heating
AC 230V
L
Use
or buttons
to set the hour.
Press
to confirm the changes.
NSB
Night SetBack (output 230 V AC)
Switched output (230 V AC)
External temperature sensor
N
7. Holiday mode
SL
8. Frost protection mode
9. Temperature unit
10. Manual mode / temp. override
S1, S2
7
Similarly to steps 5 and 6, set the minutes, year, month and day.
Note: In the KL06 wiring centre, the SL terminal is marked with an arrow
icon
.
| General | Details |
|---|---|
| Name | SALUS Programmable Wired Thermostat VS30W/VS30B Installation Guide |
| Make | SALUS |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.81 MB |

SALUS IT800 WIFI Smart Thermostat Installation Guide

SALUS 091FLRF Wireless Room Thermostat User Guide

SALUS Thermostat Sensor TS600 User Guide

SALUS Thermostat and Smart Plug Installation Guide

SALUS Wired Thermostat Installation Guide

SALUS Wired Digital Thermostat – Non-programmable HTRS230 User Manual

SALUS RT520 Radiator Thermostat User Guide

SALUS RT310 Thermostat User Manual

SALUS Thermostat RT520 User Manual

SALUS BTR230 Room Thermostat User Guide

SALUS Programmable Wired Thermostat VS30W/VS30B Installation Guide Overview
Summary of Contents
- Page 1: VS30 thermostat in connection with a boiler with a “NO” voltage free terminal through the RM-16A relay. The VS30 thermostat has been designed for flush mounting in a standard electrical box with a diameter of 60 mm. Programmable, wired thermostat with digital display for the control of temperature in UFH & RAD systems. Note: Use the rear plate of the VS30 thermostat only with this model. During the first start-up, the thermostat will automatically start time and date setting. The VS30 thermostat controls temperatures of individual heating zones in underfloor heating systems. This product complies with the following EU Directives: Electromagnetic Compatibility 2014/30/EU, Low Voltage Directive 2014/35/EU and RoHS 2011/65/EU. Installation must be carried out by a qualified person in accordance with national and EU regulations. Use the device only as intended, keeping it in a dry condition. The product is for indoor use only. The full version of the manual in PDF format is available on the website.
- Page 2: Default value and function descriptions are provided for temperature settings. The NSB function can automatically change temperatures on VS35 daily thermostats via a programmable thermostat. To activate automatic mode, select the appropriate icon on the display. The thermostat can correct wrong temperature readings by adjusting the offset temperature. Using a floor temperature sensor is necessary for certain functions. The thermostat measures temperature only on the external sensor. Frost protection mode is available for longer periods of absence or holidays. The thermostat has multiple operating modes, including comfort, standard, economic, and frost protection. Error codes are provided for troubleshooting, including temperature sensor faults. Factory settings can be restored by setting the PSuu code to 47.
- Page 3: Relay module RM-16A opens and closes the circuit to affect the work of other devices. Some uses of the module RM-16A with other Salus products include connection of the thermostat with the high voltage relay 230V. Connection of the SALUS temperature regulator with the NO/COM relay is required for solid fuel boiler controls. The maximum electricity consumption of the receiver cannot exceed 16A. Devices other than electro thermal actuators can be connected with the wiring centre. The product code for the relay module is RM-16A. Selecting electric electronic gear must comply with waste disposal regulations. The declaration of compliance is available on the Salus Controls website. The relay module is made in Poland.
- Page 4: Safety information emphasizes the importance of ensuring that the relay module's parameters match the specifications to avoid hazards. The relay module RM-16A is designed to open and close circuits to control other devices. It is crucial that connections are made by a qualified installer with current eligibility. The module can connect various devices, including thermostats and boilers, with specific output requirements. The maximum electricity consumption for connected devices should not exceed 16A. The power supply for the RM-16A module is 230V AC at 50 Hz. The module supports a control input with a voltage output of 230V. Specifications include a power rating of 16A / 250V AC and a maximum power of 4000VA. Measurements of the module are 47x47x21. The document outlines various connection scenarios for the RM-16A module with other Salus products.
- Page 5: Connection of the thermostat with a voltage relay 230V to a gas boiler which requires free-voltage output NO/COM. Connection of the SALUS temperature regulator with NO/COM relay with a boiler control which requires NC/COM output. NC/COM output is normally required in solid fuel boilers controls. A boiler with a free-voltage relay. A boiler with NC/COM input.
- Page 6: Connection diagrams Connection of the receiver transmitting power higher than it is allowed by the relay in a regulator. The maximum electricity consumption of the receiver cannot exceed 16A. Connection of devices other than electro thermal actuators with the wiring centre. Wiring centre: KL06-M / KL08NSB / KL08RF / KL10 / KL10RF. A thermostat with a free-voltage relay. A thermostat with a high voltage relay. Pump -> max 16Amps. Heating mat -> max 16Amps. Actuators -> max 16Amps.