Home > SALUS > SALUS Programmable Wired Thermostat VS30W/VS30B Installation Guide

SALUS Programmable Wired Thermostat VS30W/VS30B Installation Guide

VS30 thermostat in connection with a boiler with a “NO” voltage free  
terminal through the RM-16A relay  
Installation  
Proper thermostat placement  
The VS30 thermostat has been designed for flush mounting in  
a standard electrical box with a diameter of 60 mm.  
NSB function is not active.  
AC 230V  
1
2
3
L
M
M
T
NSB  
OUTPUT  
S1 S2  
SL  
L
N
NO  
COM  
NC  
SL  
OUTPUT  
VS30  
INPUT 230V AC  
Note: Use the rear plate of the VS30 thermostat only with this model.  
N
POWER SUPPLY  
230V AC / 50 Hz  
L
ual  
Wiring diagrams  
N
Button Functions  
An additional temperature sensor  
T
is optional.  
Button Function  
IMPORTER:  
QL CONTROLS Sp. z o.o. Sp. k.  
ul. Rolna 4, 43-262 Kobielice  
PRODUCER:  
Salus Limited  
6/F, Building 20E, Phase 3, Hong Kong  
Science Park, 20 Science Park East Avenue,  
Shatin, New Territories, Hong Kong  
VS30 thermostat in connection with actuator or pump  
Time and date setting  
Increasing / decreasing temperature or value  
AC 230V  
L
Note: During the first start-up, thermostat will automatically start time and date  
setting - in this case go to step 4.  
Selection of the operating mode, switching between values  
T
Press any button to highlight the screen, then follow the steps below:  
Short press - selection confirmation  
Long press - entry to or exit from the menu  
SALUS Controls is a member of the Computime Group  
NSB  
OUTPUT  
S1 S2  
SL  
L
N
OR  
M
1
2
Maintaining a policy of continuous product development SALUS Controls plc reserve the right to  
change specification, design and materials of products listed in this brochure without prior notice.  
+
Long press causes blocking or unlocking the thermostat  
Long press enters the installer mode  
VS30  
+
+
Introduction  
The VS30 thermostat controls temperatures of individual heating zone  
in underfloor heating systems. Thermostat allows for significant savings  
thanks to the possibility of maximum reduction the set temperature.  
The full version of the manual in PDF format is available on the website  
N
LCD Icon description  
3 sek.  
VS30 thermostat in connection with wiring centre  
3
4
1
2
3
4
5
6
7
8
In this diagram, the VS30 thermostat manages the NSB function,  
more details about NSB function can be found on the next page.  
Product Compliance  
This product complies with the following EU Directives: Electromagnetic  
Compatibility 2014/30/EU, Low Voltage Directive 2014/35/EU and  
RoHS 2011/65/EU. Full information is available on the website  
9
20  
19  
10  
11  
VS35  
VS30  
Safety Information  
Select the time format  
or buttons.  
to confirm the changes.  
INPUT  
NSB  
OUTPUT  
NSB  
Use in accordance with national and EU regulations. Use the device only as  
intended, keeping it in a dry condition. The product is for indoor use only.  
Installation must be carried out by a qualified person in accordance with  
national and EU regulations.  
S1 S2  
SL  
L
N
S1 S2  
SL  
L
N
with  
Press  
18  
17  
16  
15  
12  
13  
14  
T
T
5
6
L
L
N
N
SL  
L
N SL  
Terminals description  
11. Current / set temperature  
12. Program number  
13. AM/PM  
1.  
Current active mode  
KL08NSB  
KL06  
2. Comfort mode  
3. Standard mode  
4. Economic mode  
5. Automatic mode  
6. PARTY mode  
Terminal  
L,N  
Description  
14. Key lock  
Power Supply 230 V AC  
15. Day of the week  
16. Settings  
17. Time  
18. Additional temp. sensor  
19. Cooling  
20. Heating  
AC 230V  
L
Use  
or buttons  
to set the hour.  
Press  
to confirm the changes.  
NSB  
Night SetBack (output 230 V AC)  
Switched output (230 V AC)  
External temperature sensor  
N
7. Holiday mode  
SL  
8. Frost protection mode  
9. Temperature unit  
10. Manual mode / temp. override  
S1, S2  
7
Similarly to steps 5 and 6, set the minutes, year, month and day.  
Note: In the KL06 wiring centre, the SL terminal is marked with an arrow  
icon  
.
GeneralDetails
NameSALUS Programmable Wired Thermostat VS30W/VS30B Installation Guide
MakeSALUS
LanguageEnglish
FiletypePDF (Download)
File size0.81 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
SALUS IT800 WIFI Smart Thermostat Installation Guide
SALUS IT800 WIFI Smart Thermostat Installation Guide
SALUS 091FLRF Wireless Room Thermostat User Guide
SALUS 091FLRF Wireless Room Thermostat User Guide
SALUS Thermostat Sensor TS600 User Guide
SALUS Thermostat Sensor TS600 User Guide
SALUS Thermostat and Smart Plug Installation Guide
SALUS Thermostat and Smart Plug Installation Guide
SALUS Wired Thermostat Installation Guide
SALUS Wired Thermostat Installation Guide
SALUS Wired Digital Thermostat – Non-programmable HTRS230 User Manual
SALUS Wired Digital Thermostat – Non-programmable HTRS230 User Manual
SALUS RT520 Radiator Thermostat User Guide
SALUS RT520 Radiator Thermostat User Guide
SALUS RT310 Thermostat User Manual
SALUS RT310 Thermostat User Manual
SALUS Thermostat RT520 User Manual
SALUS Thermostat RT520 User Manual
SALUS BTR230 Room Thermostat User Guide
SALUS BTR230 Room Thermostat User Guide

SALUS Programmable Wired Thermostat VS30W/VS30B Installation Guide
Get the free PDF manual for the SALUS Programmable Wired Thermostat VS30W/VS30B Installation Guide and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

SALUS Programmable Wired Thermostat VS30W/VS30B Installation Guide Overview

Summary of Contents

  • Page 1: VS30 thermostat in connection with a boiler with a “NO” voltage free terminal through the RM-16A relay. The VS30 thermostat has been designed for flush mounting in a standard electrical box with a diameter of 60 mm. Programmable, wired thermostat with digital display for the control of temperature in UFH & RAD systems. Note: Use the rear plate of the VS30 thermostat only with this model. During the first start-up, the thermostat will automatically start time and date setting. The VS30 thermostat controls temperatures of individual heating zones in underfloor heating systems. This product complies with the following EU Directives: Electromagnetic Compatibility 2014/30/EU, Low Voltage Directive 2014/35/EU and RoHS 2011/65/EU. Installation must be carried out by a qualified person in accordance with national and EU regulations. Use the device only as intended, keeping it in a dry condition. The product is for indoor use only. The full version of the manual in PDF format is available on the website.
  • Page 2: Default value and function descriptions are provided for temperature settings. The NSB function can automatically change temperatures on VS35 daily thermostats via a programmable thermostat. To activate automatic mode, select the appropriate icon on the display. The thermostat can correct wrong temperature readings by adjusting the offset temperature. Using a floor temperature sensor is necessary for certain functions. The thermostat measures temperature only on the external sensor. Frost protection mode is available for longer periods of absence or holidays. The thermostat has multiple operating modes, including comfort, standard, economic, and frost protection. Error codes are provided for troubleshooting, including temperature sensor faults. Factory settings can be restored by setting the PSuu code to 47.
  • Page 3: Relay module RM-16A opens and closes the circuit to affect the work of other devices. Some uses of the module RM-16A with other Salus products include connection of the thermostat with the high voltage relay 230V. Connection of the SALUS temperature regulator with the NO/COM relay is required for solid fuel boiler controls. The maximum electricity consumption of the receiver cannot exceed 16A. Devices other than electro thermal actuators can be connected with the wiring centre. The product code for the relay module is RM-16A. Selecting electric electronic gear must comply with waste disposal regulations. The declaration of compliance is available on the Salus Controls website. The relay module is made in Poland.
  • Page 4: Safety information emphasizes the importance of ensuring that the relay module's parameters match the specifications to avoid hazards. The relay module RM-16A is designed to open and close circuits to control other devices. It is crucial that connections are made by a qualified installer with current eligibility. The module can connect various devices, including thermostats and boilers, with specific output requirements. The maximum electricity consumption for connected devices should not exceed 16A. The power supply for the RM-16A module is 230V AC at 50 Hz. The module supports a control input with a voltage output of 230V. Specifications include a power rating of 16A / 250V AC and a maximum power of 4000VA. Measurements of the module are 47x47x21. The document outlines various connection scenarios for the RM-16A module with other Salus products.
  • Page 5: Connection of the thermostat with a voltage relay 230V to a gas boiler which requires free-voltage output NO/COM. Connection of the SALUS temperature regulator with NO/COM relay with a boiler control which requires NC/COM output. NC/COM output is normally required in solid fuel boilers controls. A boiler with a free-voltage relay. A boiler with NC/COM input.
  • Page 6: Connection diagrams Connection of the receiver transmitting power higher than it is allowed by the relay in a regulator. The maximum electricity consumption of the receiver cannot exceed 16A. Connection of devices other than electro thermal actuators with the wiring centre. Wiring centre: KL06-M / KL08NSB / KL08RF / KL10 / KL10RF. A thermostat with a free-voltage relay. A thermostat with a high voltage relay. Pump -> max 16Amps. Heating mat -> max 16Amps. Actuators -> max 16Amps.