Home > SALUS > SALUS RT520 Radiator Thermostat User Guide

SALUS RT520 Radiator Thermostat User Guide

13  
14a  
14b  
Button Functions  
RT520TX Wiring Diagram  
RT520 / RT520RF Thermostat  
RXRT520 Receiver  
BOILER  
AC 230V  
OR  
L
RT520, RT520TX, RT520RF  
L
RT520TX  
L
COM  
NO  
3V  
2 x AA  
RXRT520  
Using UP or DOWN, select your  
temperature accuracy.  
PLEASE NOTE: Using the UP or DOWN keys, you can  
select the TPI or Hysteresis heating control algorithm.  
Choosing one option excludes the other.  
7
9
8
N
N
10  
14a  
N
TPI (Time Proportional & Integral) is a self-learning, time proportional  
control algorithm. TPI type control ensures economical operation of  
the system thanks to more precise temperature maintenance during  
the control process. In addition to an accurate and stable room  
temperature, the advantage of this system is the minimization of  
energy consumption and significant savings. RT520 offers 3 types of  
TPI controls:  
1.for radiators (6CPH);  
2. for underfloor heating (3CPH);  
3. for electric heating (9CPH).  
PUMP  
1
2
3
4
5
6
AC 230V  
7. ON - When in Manual Mode, ON will  
turn the boiler on.  
8. OFF - When in Manual Mode, OFF  
will turn the boiler off.  
9. AUTO - Receiver operates in automatic  
mode according to the thermostat.  
10. MANUAL - Receiver output is  
controlled by the On/Off slide switch.  
1. MENU - enter the menu options, press and hold  
for 3 sec to return to main screen or to  
deactivate Boost Mode.  
2. SELECT - confirm changes and enter menus.  
3. DOWN - decrease the temperature and  
move through the menus.  
4. UP - increase the temperature and move  
through menus.  
5. BOOST - activate Boost Mode.  
6. MANUAL - activate / deactivate Manual Mode.  
L
RT520TX  
L
COM  
NO  
3V  
2 x AA  
OR  
RXRT520  
MAX  
16 (5) A  
Press OK button.  
N
15
1
15c  
N
Quick Guide  
OpenTherm Power Up and Configuration  
1
Text Bar  
Temperature Unit  
LCD Icon Description  
2
Please make the receiver connections and power the receiver before inserting the batteries  
into the thermostat.  
3A Day of the week (numeric)  
3B Day of the week (alphabetic)  
Introduction  
1
2
The RT520 and RT520RF are the latest additions to SALUS’ tried and tested RT range of thermostat  
heating controls. With a new on-board load compensation feature, they offer the most cost effective  
fully compliant Boiler Plus solution on the market providing the homeowner with optimum efficiency  
and maximum heating control comfort. Available in both wired and wireless RF versions, the new RT520  
series include all the features of the previous RT series with a larger more intuitive LCD display and a  
handy new suite of additional operational and efficiency functions.  
4
5
6
7
8
9
Clock  
AM / PM  
Cooling Mode On  
Holiday Mode On  
Manual Mode On  
Heating Mode On  
Using UP or DOWN, select the TPI algorithm you want to use for heating control. Press OK to confirm.  
1
2
3
7
9
4
6
8
3A 3B  
14b  
5
10  
12  
11  
Hysteresis is the temperature difference between which the thermostat  
works, keeping the set temperature. For example, if you set the  
temperature to 20°C and if the hysteresis is 0.5°C, the heating will be  
turned on when the room temperature drops to 19.5°C and turned off  
when the temperature reaches 20.5°C.  
13  
10 Low battery status  
11 Wireless connection with the  
receiver  
Before use please read this manual carefully.  
Product Compliance  
17  
12 Service Mode On  
13 Temperature measured / set  
14 Program number  
15 Settings  
14  
This product complies with the essential requirements and other relevant provisions of the following EU Directives:  
EMC 2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU and RoHS 2011/65/EU. Full text of the EU Declaration of  
15  
16  
After inserting the batteries, the  
thermostat will power up.  
Press OK.  
Using UP or DOWN, choose your  
language and then press OK.  
Press OK button.  
16 Program indicator  
17 Boost function  
15a  
15b  
868.0-868.6MHz; <13dBm  
4
5
6
Safety Information  
RT520 Thermostat Terminals Description  
Use in accordance to national and EU regulations. Use the device as intended, keeping it in dry condition.  
Product for indoor use only. Installation must be carried out by a qualified person in accordance to national  
and EU regulations.  
Terminal  
Description  
Always ensure the AC mains power is switched off before installing or working on any  
components (this includes replacing the batteries). Use only AA 1.5 V alkaline batteries in the  
thermostat. Place the batteries into the battery slot located in the back of the thermostat. Do  
not use rechargeable batteries.  
B / A  
NC  
OpenTherm Communication Wire  
Switched Live OFF  
Using UP or DOWN select the  
hysteresis value.  
Press OK to confirm.  
NO  
Switched Live ON  
Using UP or DOWN, choose  
the time format.  
Using UP or DOWN, set the hour  
and then press OK.  
Using UP or DOWN, set the  
minutes and then press OK.  
COM  
Common Terminal  
Technical Specification  
IMPORTER:  
QL CONTROLS Sp. z o.o. Sp. k.  
ul. Rolna 4, 43-262 Kobielice  
PRODUCER:  
Salus Limited  
7
8
9
RT520TX Thermo-  
RT520 Thermostat  
RXRT520 Receiver Terminals Description  
stat (transmitter)  
6/F, Building 20E, Phase 3,  
Hong Kong Science Park,  
20 Science Park East Avenue, Shatin,  
New Territories, Hong Kong  
Thermostat supply  
2 x AA alkaline batteries 2 x AA alkaline batteries  
Terminal  
B / A  
Description  
Thermostat rating max  
OpenTherm terminals  
3 (1) A  
A / B  
-
-
OpenTherm Communication Wire  
Switch Terminal  
NO  
Voltage free  
NC / NO / COM terminals  
Outputs  
-
COM  
Common Switch Terminal  
Supply (230 V AC)  
L; N  
Temperature range  
Temperature accuracy  
ErP control class  
5°C – 33.5°C  
5°C – 33.5°C  
0.1°C OR 0.5°C  
V
Using UP or DOWN, set the year  
and then press OK.  
Using UP or DOWN, set the month Using UP or DOWN, set the day  
and then press OK.  
and then press OK.  
0.1°C OR 0.5°C  
V
-
10  
11  
12  
Radio frequency  
868 MHz  
RT520 Wiring Diagram  
BOILER  
Dimension [mm]  
118 x 95 x 26 [mm] 118 x 95 x 26 [mm]  
PUMP  
AC 230V  
RXRT520 Receiver  
L
N
SALUS Controls is a member of the Computime Group.  
RT520  
Receiver supply  
Receiver rating max  
OpenTherm terminals  
Outputs  
230 V AC  
RT520  
16 (5) A  
NC  
Maintaining a policy of continuous product development SALUS Controls plc  
reserve the right to change specification, design and materials of products listed  
in this brochure without prior notice.  
NC  
COM  
NO  
3V  
2 x AA  
3V  
2 x AA  
A / B  
COM  
MAX  
3 (1) A  
Using UP or DOWN, select the  
week format.  
Using UP or DOWN, enable or  
disable DST (Daylight Saving Time)  
and then press OK.  
To select the accuracy of the  
displayed temperature  
press OK to confirm.  
Voltage free NO / COM terminals  
868 MHz  
NO  
Radio frequency  
Dimension [mm]  
Issue date: August 2021  
V15  
96 x 96 x 26 [mm]  
GeneralDetails
NameSALUS RT520 Radiator Thermostat User Guide
MakeSALUS
LanguageEnglish
FiletypePDF (Download)
File size0.92 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
SALUS IT800 WIFI Smart Thermostat Installation Guide
SALUS IT800 WIFI Smart Thermostat Installation Guide
SALUS 091FLRF Wireless Room Thermostat User Guide
SALUS 091FLRF Wireless Room Thermostat User Guide
SALUS Thermostat Sensor TS600 User Guide
SALUS Thermostat Sensor TS600 User Guide
SALUS Thermostat and Smart Plug Installation Guide
SALUS Thermostat and Smart Plug Installation Guide
SALUS Programmable Wired Thermostat VS30W/VS30B Installation Guide
SALUS Programmable Wired Thermostat VS30W/VS30B Installation Guide
SALUS Wired Thermostat Installation Guide
SALUS Wired Thermostat Installation Guide
SALUS Wired Digital Thermostat – Non-programmable HTRS230 User Manual
SALUS Wired Digital Thermostat – Non-programmable HTRS230 User Manual
SALUS RT310 Thermostat User Manual
SALUS RT310 Thermostat User Manual
SALUS Thermostat RT520 User Manual
SALUS Thermostat RT520 User Manual
SALUS iT500 Internet Thermostat Installation Guide
SALUS iT500 Internet Thermostat Installation Guide

SALUS RT520 Radiator Thermostat User Guide
Get the free PDF manual for the SALUS RT520 Radiator Thermostat User Guide and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

SALUS RT520 Radiator Thermostat User Guide Overview

Summary of Contents

  • Page 1: Button functions include MENU, SELECT, DOWN, UP, BOOST, and MANUAL. The RT520 and RT520RF are part of the SALUS RT range of thermostat heating controls. These thermostats feature a load compensation feature for cost-effective operation. The RT520 series includes a larger LCD display and additional operational functions. TPI is a self-learning control algorithm that ensures economical operation and precise temperature maintenance. Hysteresis is the temperature difference that the thermostat maintains around the set temperature. The product complies with essential EU Directives regarding safety and performance. Installation must be performed by a qualified person in accordance with national and EU regulations. The thermostat requires 2 x AA alkaline batteries for operation. The technical specifications include a temperature range of 5°C to 33.5°C and a radio frequency of 868 MHz.
  • Page 2: Programming - Automatic mode allows for 6 time intervals with adjustable temperatures. You can set 2, 3, or up to 6 temperatures per day, and all time periods must be defined. Administrator settings require a PIN code to set a service reminder for boiler inspection. The OPTIMUM START function sends a heating signal in advance to reach the preset temperature. Pairing the RT520TX thermostat with the receiver requires the devices to be at least 1 meter apart. The OPTIMUM STOP function switches off the heat source earlier, maintaining the scheduled temperature. To enter Administrator mode, use the UP or DOWN buttons to enter the PIN code and confirm each numeral. The pairing process can take up to 10 minutes, and successful pairing is indicated by a solid red LED. In manual mode, the user can set the desired temperature that the thermostat will maintain. To reset the thermostat, press MENU, DOWN, and BOOST simultaneously for 5 seconds.