SALUS RT520 Radiator Thermostat User Guide
13
14a
14b
Button Functions
RT520TX Wiring Diagram
RT520 / RT520RF Thermostat
RXRT520 Receiver
BOILER
AC 230V
OR
L
RT520, RT520TX, RT520RF
L
RT520TX
L
COM
NO
3V
2 x AA
RXRT520
Using UP or DOWN, select your
temperature accuracy.
PLEASE NOTE: Using the UP or DOWN keys, you can
select the TPI or Hysteresis heating control algorithm.
Choosing one option excludes the other.
7
9
8
N
N
10
14a
N
TPI (Time Proportional & Integral) is a self-learning, time proportional
control algorithm. TPI type control ensures economical operation of
the system thanks to more precise temperature maintenance during
the control process. In addition to an accurate and stable room
temperature, the advantage of this system is the minimization of
energy consumption and significant savings. RT520 offers 3 types of
TPI controls:
1.for radiators (6CPH);
2. for underfloor heating (3CPH);
3. for electric heating (9CPH).
PUMP
1
2
3
4
5
6
AC 230V
7. ON - When in Manual Mode, ON will
turn the boiler on.
8. OFF - When in Manual Mode, OFF
will turn the boiler off.
9. AUTO - Receiver operates in automatic
mode according to the thermostat.
10. MANUAL - Receiver output is
controlled by the On/Off slide switch.
1. MENU - enter the menu options, press and hold
for 3 sec to return to main screen or to
deactivate Boost Mode.
2. SELECT - confirm changes and enter menus.
3. DOWN - decrease the temperature and
move through the menus.
4. UP - increase the temperature and move
through menus.
5. BOOST - activate Boost Mode.
6. MANUAL - activate / deactivate Manual Mode.
L
RT520TX
L
COM
NO
3V
2 x AA
OR
RXRT520
MAX
16 (5) A
Press OK button.
N
15
1
15c
N
Quick Guide
OpenTherm Power Up and Configuration
1
Text Bar
Temperature Unit
LCD Icon Description
2
Please make the receiver connections and power the receiver before inserting the batteries
into the thermostat.
3A Day of the week (numeric)
3B Day of the week (alphabetic)
Introduction
1
2
The RT520 and RT520RF are the latest additions to SALUS’ tried and tested RT range of thermostat
heating controls. With a new on-board load compensation feature, they offer the most cost effective
fully compliant Boiler Plus solution on the market providing the homeowner with optimum efficiency
and maximum heating control comfort. Available in both wired and wireless RF versions, the new RT520
series include all the features of the previous RT series with a larger more intuitive LCD display and a
handy new suite of additional operational and efficiency functions.
4
5
6
7
8
9
Clock
AM / PM
Cooling Mode On
Holiday Mode On
Manual Mode On
Heating Mode On
Using UP or DOWN, select the TPI algorithm you want to use for heating control. Press OK to confirm.
1
2
3
7
9
4
6
8
3A 3B
14b
5
10
12
11
Hysteresis is the temperature difference between which the thermostat
works, keeping the set temperature. For example, if you set the
temperature to 20°C and if the hysteresis is 0.5°C, the heating will be
turned on when the room temperature drops to 19.5°C and turned off
when the temperature reaches 20.5°C.
13
10 Low battery status
11 Wireless connection with the
receiver
Before use please read this manual carefully.
Product Compliance
17
12 Service Mode On
13 Temperature measured / set
14 Program number
15 Settings
14
This product complies with the essential requirements and other relevant provisions of the following EU Directives:
EMC 2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU and RoHS 2011/65/EU. Full text of the EU Declaration of
15
16
After inserting the batteries, the
thermostat will power up.
Press OK.
Using UP or DOWN, choose your
language and then press OK.
Press OK button.
16 Program indicator
17 Boost function
15a
15b
868.0-868.6MHz; <13dBm
4
5
6
Safety Information
RT520 Thermostat Terminals Description
Use in accordance to national and EU regulations. Use the device as intended, keeping it in dry condition.
Product for indoor use only. Installation must be carried out by a qualified person in accordance to national
and EU regulations.
Terminal
Description
Always ensure the AC mains power is switched off before installing or working on any
components (this includes replacing the batteries). Use only AA 1.5 V alkaline batteries in the
thermostat. Place the batteries into the battery slot located in the back of the thermostat. Do
not use rechargeable batteries.
B / A
NC
OpenTherm Communication Wire
Switched Live OFF
Using UP or DOWN select the
hysteresis value.
Press OK to confirm.
NO
Switched Live ON
Using UP or DOWN, choose
the time format.
Using UP or DOWN, set the hour
and then press OK.
Using UP or DOWN, set the
minutes and then press OK.
COM
Common Terminal
Technical Specification
IMPORTER:
QL CONTROLS Sp. z o.o. Sp. k.
ul. Rolna 4, 43-262 Kobielice
PRODUCER:
Salus Limited
7
8
9
RT520TX Thermo-
RT520 Thermostat
RXRT520 Receiver Terminals Description
stat (transmitter)
6/F, Building 20E, Phase 3,
Hong Kong Science Park,
20 Science Park East Avenue, Shatin,
New Territories, Hong Kong
Thermostat supply
2 x AA alkaline batteries 2 x AA alkaline batteries
Terminal
B / A
Description
Thermostat rating max
OpenTherm terminals
3 (1) A
A / B
-
-
OpenTherm Communication Wire
Switch Terminal
NO
Voltage free
NC / NO / COM terminals
Outputs
-
COM
Common Switch Terminal
Supply (230 V AC)
L; N
Temperature range
Temperature accuracy
ErP control class
5°C – 33.5°C
5°C – 33.5°C
0.1°C OR 0.5°C
V
Using UP or DOWN, set the year
and then press OK.
Using UP or DOWN, set the month Using UP or DOWN, set the day
and then press OK.
and then press OK.
0.1°C OR 0.5°C
V
-
10
11
12
Radio frequency
868 MHz
RT520 Wiring Diagram
BOILER
Dimension [mm]
118 x 95 x 26 [mm] 118 x 95 x 26 [mm]
PUMP
AC 230V
RXRT520 Receiver
L
N
SALUS Controls is a member of the Computime Group.
RT520
Receiver supply
Receiver rating max
OpenTherm terminals
Outputs
230 V AC
RT520
16 (5) A
NC
Maintaining a policy of continuous product development SALUS Controls plc
reserve the right to change specification, design and materials of products listed
in this brochure without prior notice.
NC
COM
NO
3V
2 x AA
3V
2 x AA
A / B
COM
MAX
3 (1) A
Using UP or DOWN, select the
week format.
Using UP or DOWN, enable or
disable DST (Daylight Saving Time)
and then press OK.
To select the accuracy of the
displayed temperature
press OK to confirm.
Voltage free NO / COM terminals
868 MHz
NO
Radio frequency
Dimension [mm]
Issue date: August 2021
V15
96 x 96 x 26 [mm]
| General | Details |
|---|---|
| Name | SALUS RT520 Radiator Thermostat User Guide |
| Make | SALUS |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.92 MB |

SALUS IT800 WIFI Smart Thermostat Installation Guide

SALUS 091FLRF Wireless Room Thermostat User Guide

SALUS Thermostat Sensor TS600 User Guide

SALUS Thermostat and Smart Plug Installation Guide

SALUS Programmable Wired Thermostat VS30W/VS30B Installation Guide

SALUS Wired Thermostat Installation Guide

SALUS Wired Digital Thermostat – Non-programmable HTRS230 User Manual

SALUS RT310 Thermostat User Manual

SALUS Thermostat RT520 User Manual

SALUS iT500 Internet Thermostat Installation Guide

SALUS RT520 Radiator Thermostat User Guide Overview
Summary of Contents
- Page 1: Button functions include MENU, SELECT, DOWN, UP, BOOST, and MANUAL. The RT520 and RT520RF are part of the SALUS RT range of thermostat heating controls. These thermostats feature a load compensation feature for cost-effective operation. The RT520 series includes a larger LCD display and additional operational functions. TPI is a self-learning control algorithm that ensures economical operation and precise temperature maintenance. Hysteresis is the temperature difference that the thermostat maintains around the set temperature. The product complies with essential EU Directives regarding safety and performance. Installation must be performed by a qualified person in accordance with national and EU regulations. The thermostat requires 2 x AA alkaline batteries for operation. The technical specifications include a temperature range of 5°C to 33.5°C and a radio frequency of 868 MHz.
- Page 2: Programming - Automatic mode allows for 6 time intervals with adjustable temperatures. You can set 2, 3, or up to 6 temperatures per day, and all time periods must be defined. Administrator settings require a PIN code to set a service reminder for boiler inspection. The OPTIMUM START function sends a heating signal in advance to reach the preset temperature. Pairing the RT520TX thermostat with the receiver requires the devices to be at least 1 meter apart. The OPTIMUM STOP function switches off the heat source earlier, maintaining the scheduled temperature. To enter Administrator mode, use the UP or DOWN buttons to enter the PIN code and confirm each numeral. The pairing process can take up to 10 minutes, and successful pairing is indicated by a solid red LED. In manual mode, the user can set the desired temperature that the thermostat will maintain. To reset the thermostat, press MENU, DOWN, and BOOST simultaneously for 5 seconds.