Home > GENERAL LIFE > GENERAL LIFE NORA 270S RF Wireless Room Thermostat User Manual

GENERAL LIFE NORA 270S RF Wireless Room Thermostat User Manual

ProductDisplayLayout  
RECEIVER WIRING DIAGRAM  
ENGLISH  
AC  
COM  
NO  
(230V)  
5
6
7
DIGITAL ROOM THERMOSTAT  
generallife.com.tr  
1
2
3
BATTERY PLACEMENT  
NORA 270S RF USER MANUAL  
4
HEATING/COOLING UNIT  
GENERAL SPECIFICATIONS  
Warning!  
Operations within the heating / cooling unit or the electrical installation  
must be carriedout byprofessionally qualified persons.  
1
2
3
4
Room Temperature  
NORA 270S RF is a wireless room thermostat. The user can adjust the room  
temperature with the required temperature and get more comfortable and  
economic heating/cooling.  
Set Temperature  
Economy Mode  
Comfort Mode  
Heating Indicator  
Different Mode Options (Comfort Mode and Economy Mode)  
PAIRING THE ROOM THERMOSTAT AND THE RECEIVER  
Primarily press the sync button of receiver for 2 seconds and see blinking  
5
- If the Heating Indicator is blinking, the heating unit is working.  
- If the Heating Indicator is steady, the heating unit is not working.  
Cooling Indicator  
- If the Cooling Indicator is blinking, the cooling unit is working.  
- If the Cooling Indicator is steady, the cooling unit is not working.  
Battery Indicator  
PreciseTemperatureMeasurement  
Heating Calibration  
ON/OFFControl  
WirelessConnection  
TPIAlgorithm  
green light of receiver.  
While your device is turned off, press and hold the "On/Off"button for 3  
seconds.  
Heating/Cooling Modes  
6
7
As shown in the picture above, press the screwdriverforward from the space  
shown, bend the tabs and separate the front cover. Insert 2 new AAA alkaline  
batteries in the battery housing with the correct battery direction. Replace  
both batteries at the same time. Then align the front part of your Room  
Thermostatto the backand squeezeittowards theback.  
NORA 270S RF AND EQUIPMENTS  
NORA 270S RF Room Thermostat  
Press thebutton until the “  
” menu appears.  
Holder  
Alkaline Battery  
Press the "+" or "-" button of your Room Thermostat while the LED is  
flashing green.  
RECEIVER  
If the pairing is successful, the green flashing LED on the receiver will be  
constant.  
1-Manual Operation Button:  
Deactivates the Receiver and allows you to  
use heating/cooling unit manually.  
2-Pairing Button:  
1
2
3
LowBattery Warning:When the icon appears on the screen, itmeans  
“low battery warning”. Itis recommended to replacethebatterieswhen this  
warning appears.  
Receiverand Room Thermostathavebeen paired to each other.  
ROOM THERMOSTATTEMPERATURE CALIBRATION  
Temperature sensors which are used in Room Thermostats are highly  
sensitive. You mayneed to calibrate yourRoom Thermostat if youwould like  
to get the same temperature values with other thermometers in your living  
space.  
Allows to pair the Receiver with the Room  
Thermostat.  
3-Receiver LED Light  
4-Receiver Power Cable Input  
5-Heating/Cooling Unit Connection Cable  
Input  
Dowels and Screws  
Receiver  
Warning: When the product is not used for a long period (more than 15 days),  
removethebatteries. Otherwise, malfunctions thatmay occurwould beoutof  
warranty.  
Please throwyourdead batteries into thewaste bin forbatteries.  
While your device is turned off, press and hold the "On/Off"button for 3  
seconds.  
RECEIVER PLACEMENT  
Press the "On/Off" button until the “  
” menu appers. In order to see the  
4 5  
RECEIVER LED DESCRIPTIONS  
The important things to note for the Receiver  
placementis avoidingphysical contactbetweenthe  
Receiverand heating/cooling unit, and protecting it  
against materialssuch asliquid, dust etc.  
desired temperature, set the temperature difference by press the  
“Temperature Adjustment Buttons”. This value can be arranged between  
“-8oC" and “+8oC".  
TECHNICAL DATA  
Room Thermostat  
Dimensions  
Operating Current  
85mm / 125mm / 19.2mm  
3V DC (2 x AAA alkaline battery)  
Steady Red  
Receiver has power but Receiver and Room  
To save the settings and exit, press the "On/Off" button until the device  
turns off.  
Thermostat are not paired.  
Temperature Measurement Accuracy 0.1oC  
Thedevicesshouldbeplacedin ordertominimizethedamagetothe  
receivedand transmittedsignals bypayingattentiontothefollowingpoints;  
Note:Recommended tempreturecalibration is “0.0oC”.  
Blinking Green  
Steady Green  
Waiting for pairing signal from the Room Thermostat.  
Receiver and Room Thermostat are paired.  
Heating/cooling unit is not operating.  
Operate the heating/cooling unit signal has reached  
to the Receiver.  
Operating Temperature Range  
Battery Life  
Operating Temperature  
Storage Temperature  
(5oC) – (30oC)  
1 Year (2 x AAA)  
(-10oC) – (+50oC)  
(-20oC) – (+60oC)  
The devicesshould not be mounted on metalsurfaces.  
The devices should not be installed close to electrical cables and  
electronic equipment such ascomputers and televisionunits.  
The devices should not be installed near large metal structures or other  
building materials using fine metal meshes such as special glass or  
special concrete.  
FACTORY SETTINGS RESET  
3 Short Orange  
Blinking  
You can reset your Room Thermostat to its default factory settings. This  
operation resets the mode temperature values, calibration setting and  
heating/coling modes to factory setting. To reset your Room Thermostat to  
factory setting:  
Steady Orange  
3 Short Green  
Blinking  
Heating/cooling unit is operating.  
Shut the heating/cooling unit down signal has  
reached to the Receiver.  
Receiver  
Dimensions  
Operation Current  
Relay NO Switching Current  
90mm / 90mm / 25mm  
230V AC  
7A (240VAC – Resistive load)  
10A (120VAC – Resistive load)  
(-20oC) – (+60oC)  
Blinking Orange  
Heating/Cooling unit operates in manual mode.  
While your device is turned off, press and hold the "On/Off"button for 3  
seconds.  
Distance between the Room Thermostat and the Receiver should not  
exceed 20metersor 2 floors.  
Blinking Red  
Receiver did not get any signal from the Room  
Thermostat for 22 minutes or longer.  
Heating/cooling unit has shut down.  
PresstheOn/Off” button until “  
While in the “ ” menu, select the “  
and press the “On/Off” button.  
Your devicewill be turned off and resetto factory settings.  
” menu appears.  
Receiver must be installed at least 50 cm away from the heating/cooling  
unit.  
” option by using “+” or “-” buttons  
Storage Temperature  
ROOM THERMOSTAT PLACEMENT  
RECEIVER SETUP  
ROOM THERMOSTAT  
Buttons Functions  
Room Thermostat needs to be placed in the room which is used most  
frequently. For instance; living room or lounge. Placing the Room  
Thermostat in a spot that have air circulation like entrance of a room or side  
of window should be avoided. Also anywhere close to heating/cooling units  
such as radiator, stove and spots which get direct sun lights would not be  
suitable. Room Thermostat needs to be located above the floor 150 cm  
height. Fewtrialsmaybe made to find themost convenientspot.  
First, shut down your heating/cooling unit and your heating/cooling unit's  
power sourcewith allelectricalcurrent(fuse, socketetc.)  
As shown in the connection diagram, connect one end of the heating /  
cooling unit connection cable to the COM and the other to the NO input of  
the Receiver.  
MODE SETTINGS  
There are 2 modes in the Room Thermostat. These are Comfort Mode “  
and Economy Mode “ ”. Modes work according to the pre-set temperature  
valuesadjusted byuser.  
1
2
In order to change thecomfort mode temperaturevalue;  
Connect the other ends of the cable -which you connected to the Receiver  
to room thermostat connection terminal as shown in your heating /  
cooling unit's user manual.  
Press and hold thecomfort mode button for 3 seconds.  
Change the temperaturevaluebypressing “+” or “-“ buttons.  
Press the comfort mode button once to save the changes you have made  
or wait10seconds.  
3
4
5
You must first connect the Receiver power cable to the Receiver and then  
to the fuse to which the heating/cooling unit is connected.  
After completing the cable connection process, firstly turn on your fuse  
and then yourheating/cooling unit.  
6
In order to change the economy mode temperaturevalue;  
Press and hold theeconomy mode button for 3 seconds.  
Change the temperaturevaluebypressing “+” or “-” buttons.  
Press the economy mode button once to savethe changes youhavemade  
or wait10seconds.  
By pressing the Receiver's manual usage button for 2 seconds, youshould  
see the Orange Light blinking on the Receiver. In this way, after making  
sure that the heating/cooling unit is operating, press the same button  
again for 2 seconds and seethattheOrangeLEDturns off.  
Set up the Room Thermostat to pair the Receiver with the Room  
Thermostat.  
1
2
3
4
5
6
Economy Mode  
Temperature Adjustment (Increasing)  
Comfort Mode  
Heating/Cooling Modes  
Temperature Adjustment (Decreasing)  
ON/OFF and Setting Button  
You can use the+” and “-” buttons to use theRoom Thermostatmanually.  
1
2
3
4
GeneralDetails
NameGENERAL LIFE NORA 270S RF Wireless Room Thermostat User Manual
MakeGENERAL LIFE
LanguageEnglish
FiletypePDF (Download)
File size2.3 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
GENERAL LIFE HT330S RF Room Thermostat User Manual
GENERAL LIFE HT330S RF Room Thermostat User Manual
GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual
GENERAL LIFE HT250 RF Digital Room Thermostat User Manual
GENERAL LIFE HT250 RF Digital Room Thermostat User Manual
GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual
GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual
GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual
GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual
GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual
GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual
GENERAL LIFE HT220S RF Digital Room Thermostat User Manual
GENERAL LIFE HT220S RF Digital Room Thermostat User Manual
GENERAL LIFE 270S RF Room Thermostat User Manual
GENERAL LIFE 270S RF Room Thermostat User Manual
GENERAL LIFE 270 Wireless Room Thermostat User Manual
GENERAL LIFE 270 Wireless Room Thermostat User Manual

GENERAL LIFE NORA 270S RF Wireless Room Thermostat User Manual
Get the free PDF manual for the GENERAL LIFE NORA 270S RF Wireless Room Thermostat User Manual and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

GENERAL LIFE NORA 270S RF Wireless Room Thermostat User Manual Overview

Summary of Contents

  • Page 1: Product display layout Receiver wiring diagram Nora 270S RF is a wireless room thermostat. The user can adjust the room temperature for more comfortable and economic heating/cooling. Different mode options include comfort mode and economy mode. Battery placement instructions for the thermostat. Warning: Operations within the heating/cooling unit or the electrical installation must be carried out by professionally qualified persons. Temperature sensors in room thermostats are highly sensitive and may require calibration for accurate readings. Receiver placement should avoid physical contact with heating/cooling units and protect against liquids and dust. The device should not be mounted on metal surfaces or near electrical cables and electronic equipment. Factory settings can be reset to restore default temperature values and calibration settings.
  • Page 2: Warranty conditions state that the warranty period starts from the invoice date and covers manufacturing defects for 5 years. The room thermostat sends a status signal to the receiver every 10 minutes to ensure synchronized operation. If the signal is lost for 22 minutes, the receiver stops heating or cooling for safety. The TPI algorithm in the thermostat predicts temperature changes to maintain the set temperature efficiently. Devices are delivered in working condition, and on-site commissioning incurs a service fee. Repairs under warranty are conducted at the company factory, with transportation costs borne by the customer for on-site services. Malfunctions caused by customer misuse are not covered by the warranty. The learning process of the TPI thermostat restarts if the device is moved or de-energized. Customers must report any product damages within the warranty period to maintain their rights. The warranty does not cover damages from unauthorized use or external factors like natural disasters.