ScreenIndicators  
As shown in the picture, press the screwdriver forward from the space  
shown, bend the tabs and separate the front cover. Insert 2 new AAA  
alkaline batteries in the battery housing with the correct battery  
direction. Replace both batteries at the same time. Then align the  
front part of your Room Thermostat to the back and squeeze it  
towards the back.  
ENGLISH  
5
6
7
DIGITAL ROOM THERMOSTAT  
generallife.com.tr  
1
Low Battery Warning: When the “ ” icon appears on the screen, it  
means “low battery warning”. It is recommended to replace the  
batterieswhen this warning appears.  
2
3
NORA 270S USER MANUAL  
GENERALSPECIFICATIONS  
Warning: When the product is not used for a long period (more than 15  
days), remove the batteries. Otherwise, malfunctions that may occur  
would beoutof warranty.  
4
DIGITAL ROOM THERMOSTAT  
NORA 270S is a wired room thermostat. The user can adjust the room  
temperature with the required temperature and get more comfortable  
and economic heating/cooling.  
1
2
3
4
Room Temperature  
Set Temperature  
Economy Mode  
Comfort Mode  
Heating Indicator  
- If the Heating Indicator is blinking, the heating unit is  
working.  
- If the Heating Indicator is steady, the heating unit is not  
Pleasethrow yourdead batteriesinto the wastebin for batteries.  
ROOMTHERMOSTATWIRINGDIAGRAM  
DifferentMode Options (Comfort Mode and Economy Mode)  
HEATING/COOLING UNIT  
PreciseTemperatureMeasurement  
Heating Calibration  
ON/OFFControl  
Wired Connection  
TPIAlgorithm  
NORA 270S  
USER MANUAL  
5
Heating/Cooling Modes  
working.  
Cooling Indicator  
NORA270SANDEQUIPMENTS  
- If the Cooling Indicator is blinking, the cooling unit is  
working.  
- If the Cooling Indicator is steady, the cooling unit is not  
working.  
Battery Indicator  
NORA 270S Room Thermostat Alkaline Battery  
Dowels and  
Screws  
6
7
NO COM  
Warning!  
Operations within the heating  
ROOMTHERMOSTATPLACEMENT  
/
cooling unit or the electrical  
Room Thermostat needs to be placed in the room which is used most  
frequently. For instance; living room or lounge. Placing the Room  
Thermostat in a spot that have air circulation like entrance of a room  
or side of window should be avoided. Also anywhere close to  
heating/cooling units such as radiator, stove and spots which get  
direct sun lights would not be suitable. Room Thermostat needs to be  
located above the floor 150 cm height. Few trials may be made to find  
themost convenientspot.  
installation must be carriedout byprofessionally qualified persons.  
TECHNICALDATA  
ROOMTHERMOSTATTEMPERATURECALIBRATION  
Temperature sensors which are used in Room Thermostats are highly  
sensitive. You may need to calibrate your Room Thermostat if you  
would like to get the same temperature values with other  
thermometersin yourliving space.  
Dimensions  
Operating Current  
Relay NO Switching Current  
85mm / 125mm / 19.2mm  
3V DC (2 x AAA alkaline battery)  
2A/30VDC (Resistive load)  
0.5A/125VAC (Resistive load)  
0.1oC  
Temperature Measurement  
Accuracy  
Operating Temperature Range  
Battery Life  
Operating Temperature  
Storage Temperature  
While your device is turned off, press and hold the "On/Off"button  
for 3 seconds.  
(5oC) – (30oC)  
1 Year (2 x AAA)  
(-10oC) – (+50oC)  
(-20oC) – (+60oC)  
Press the "On/Off" button until the “  
” menu appers. In order to  
see the desired temperature, set the temperature difference by  
press the “Temperature Adjustment Buttons”. This value can be  
arranged between “-8oC" and “+8oC".  
ROOMTHERMOSTAT  
ButtonsFunctions  
To save the settings and exit, press the "On/Off" button until the  
deviceturns off.  
Note:Recommended tempreturecalibration is “0.0oC”.  
FACTORY SETTINGS RESET  
1
2
You can reset your Room Thermostat to its default factory settings.  
This operation resets the mode temperature values, calibration  
setting and heating/coling modes to factory setting. To reset your  
Room Thermostatto factory setting:  
3
4
5
While your device is turned off, press and hold the "On/Off"button  
for 3 seconds.  
6
Pressthe “On/Off” button until “  
” menu appears.  
BATTERY PLACEMENT  
Before starting, power off the device connected to the Room  
Thermostatand makesure thatthe energy is cutoff.  
While in the “ ” menu, select the “ ” option by using “+” or “-”  
buttons and press theOn/Off” button.  
1
2
3
4
5
6
Economy Mode  
Your devicewillbe turned off and resetto factory settings.  
Temperature Adjustment (Increasing)  
Comfort Mode  
Heating/Cooling Modes  
Temperature Adjustment (Decreasing)  
ON/OFF and Setting Button  
MODESETTINGS  
There are 2 modes in the Room Thermostat. These are Comfort Mode  
” and Economy Mode “ ”. Modes work according to the pre-set  
temperaturevaluesadjusted byuser.  
In order to change thecomfort mode temperaturevalue;  
Pressand hold thecomfort mode button for 3 seconds.  
Change thetemperaturevaluebypressing “+” or “-“ buttons.  
Press the comfort mode button once to save the changes you have  
made or wait10seconds.  
generallife.com.tr  
1
2
3
GeneralDetails
NameGENERAL LIFE NORA 270S Digital Room Thermostat User Manual
MakeGENERAL LIFE
LanguageEnglish
FiletypePDF (Download)
File size2.13 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
GENERAL LIFE HT330S RF Room Thermostat User Manual
GENERAL LIFE HT330S RF Room Thermostat User Manual
GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual
GENERAL LIFE HT250 RF Digital Room Thermostat User Manual
GENERAL LIFE HT250 RF Digital Room Thermostat User Manual
GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual
GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual
GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual
GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual
GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual
GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual
GENERAL LIFE HT220S RF Digital Room Thermostat User Manual
GENERAL LIFE HT220S RF Digital Room Thermostat User Manual
GENERAL LIFE 270S RF Room Thermostat User Manual
GENERAL LIFE 270S RF Room Thermostat User Manual
GENERAL LIFE 270 Wireless Room Thermostat User Manual
GENERAL LIFE 270 Wireless Room Thermostat User Manual

GENERAL LIFE NORA 270S Digital Room Thermostat User Manual
Get the free PDF manual for the GENERAL LIFE NORA 270S Digital Room Thermostat User Manual and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

GENERAL LIFE NORA 270S Digital Room Thermostat User Manual Overview

Summary of Contents

  • Page 1: Low battery warning: When the icon appears on the screen, it means low battery warning. It is recommended to replace the batteries when this warning appears. Nora 270S is a wired room thermostat. The user can adjust the room temperature with the required temperature for more comfortable and economic heating/cooling. Room thermostat needs to be placed in the room which is used most frequently. Avoid placing it in spots with direct sunlight or near heating/cooling units. Temperature sensors in room thermostats are highly sensitive. Calibration may be needed to match temperature values with other thermometers. You can reset your room thermostat to its default factory settings. This operation resets mode temperature values, calibration settings, and heating/cooling modes. There are two modes in the room thermostat: Comfort Mode and Economy Mode. Modes work according to the pre-set temperature values adjusted by the user. To change the comfort mode temperature value, press and hold the comfort mode button for 3 seconds and adjust the temperature using the “+” or “-” buttons. Battery placement requires powering off the device connected to the room thermostat and ensuring the energy is cut off. Recommended temperature calibration is 0.0°C. Heating and cooling indicators show the operational status of the heating and cooling units.
  • Page 2: Warranty conditions state that the warranty period starts from the invoice date and covers manufacturing defects for 5 years. Devices are delivered in working condition, and on-site commissioning is subject to a service fee. Repairs covered by the warranty are carried out at the company's factory, with transportation costs borne by the customer for on-site services. Maintenance of devices is also conducted by the company, with travel fares covered by the customer. The TPI Room Thermostat uses an algorithm to maintain the desired temperature with minimal fluctuations. If the thermostat is de-energized, the learning process restarts, which takes about 7 days. Malfunctions caused by customer misuse are not covered by the warranty. The warranty does not cover damages from external factors like fire or flood. The customer must report any product damages within the warranty period to retain their rights. The warranty document must be kept safe, as a lost document will not be replaced.