Home > GENERAL LIFE > GENERAL LIFE NORA 270S RF Digital Room Thermostat User Manual
GENERAL LIFE NORA 270S RF Digital Room Thermostat User Manual
AC
(230V)
ProductDisplayLayout
RECEIVERWIRINGDIAGRAM
ENGLISH
COM
NO
5
6
7
DIGITAL ROOM THERMOSTAT
generallife.com.tr
1
2
3
BATTERY PLACEMENT
NORA 270S RF USER MANUAL
HEATING/COOLING UNIT
4
GENERALSPECIFICATIONS
Warning!
Operations within the heating / cooling unit or the electrical installation
must be carriedout byprofessionally qualified persons.
1
2
3
4
Room Temperature
NORA 270S RF is a wireless room thermostat. The user can adjust the room
temperature with the required temperature and get more comfortable and
economic heating/cooling.
Set Temperature
Economy Mode
Comfort Mode
Heating Indicator
DifferentMode Options (Comfort Mode and Economy Mode)
PAIRINGTHEROOMTHERMOSTATANDTHERECEIVER
Primarily press the sync button of receiver for 2 seconds and see blinking
5
- If the Heating Indicator is blinking, the heating unit is working.
- If the Heating Indicator is steady, the heating unit is not working.
Cooling Indicator
- If the Cooling Indicator is blinking, the cooling unit is working.
- If the Cooling Indicator is steady, the cooling unit is not working.
Battery Indicator
PreciseTemperature Measurement
Heating Calibration
ON/OFFControl
WirelessConnection
TPIAlgorithm
green light of receiver.
While your device is turned off, press and hold the "On/Off"button for 3
seconds.
Heating/Cooling Modes
6
7
As shown in the picture above, press the screwdriverforward from the space
shown, bend the tabs and separate the front cover. Insert 2 new AAA alkaline
batteries in the battery housing with the correct battery direction. Replace
both batteries at the same time. Then align the front part of your Room
Thermostatto thebackand squeezeittowards theback.
NORA 270SRF AND EQUIPMENTS
NORA 270S RF Room Thermostat
Press thebutton until the“
” menu appears.
Holder
Alkaline Battery
Press the "+" or "-" button of your Room Thermostat while the LED is
flashing green.
RECEIVER
If the pairing is successful, the green flashing LED on the receiver will be
constant.
1-Manual Operation Button:
Deactivates the Receiver and allows you to
use heating/cooling unit manually.
2-Pairing Button:
1
2
3
LowBattery Warning:When the“ ” icon appears on the screen, itmeans
“low battery warning”. Itis recommended to replacethebatterieswhen this
warning appears.
Receiverand Room Thermostathavebeen paired to each other.
ROOMTHERMOSTATTEMPERATURECALIBRATION
Temperature sensors which are used in Room Thermostats are highly
sensitive. You mayneed to calibrate yourRoom Thermostat if youwould like
to get the same temperature values with other thermometers in your living
space.
Allows to pair the Receiver with the Room
Thermostat.
3-Receiver LED Light
4-Receiver Power Cable Input
5-Heating/Cooling Unit Connection Cable
Input
Dowels and Screws
Receiver
Warning: When the product is not used for a long period (more than 15 days),
removethebatteries. Otherwise, malfunctions thatmay occurwould beoutof
warranty.
Please throwyourdead batteries into thewastebin for batteries.
While your device is turned off, press and hold the "On/Off"button for 3
seconds.
RECEIVERPLACEMENT
Press the "On/Off" button until the “
” menu appers. In order to see the
The important things to note for theReceiver
placementis avoidingphysical contactbetweenthe
Receiverand heating/cooling unit, and protecting it
against materialssuch asliquid, dust etc.
4
5
desired temperature, set the temperature difference by press the
“Temperature Adjustment Buttons”. This value can be arranged between
“-8oC" and “+8oC".
TECHNICALDATA
Room Thermostat
RECEIVERLEDDESCRIPTIONS
Dimensions
Operating Current
85mm / 125mm / 19.2mm
3V DC (2 x AAA alkaline battery)
Steady Red
Receiver has power but Receiver and Room
Thermostat are not paired.
To save the settings and exit, press the "On/Off" button until the device
turns off.
Temperature Measurement Accuracy 0.1oC
Thedevicesshouldbeplacedin ordertominimizethedamagetothe
receivedand transmittedsignals bypayingattentiontothefollowingpoints;
Note:Recommended tempreturecalibration is “0.0oC”.
Blinking Green
Steady Green
Waiting for pairing signal from the Room Thermostat.
Receiver and Room Thermostat are paired.
Heating/cooling unit is not operating.
Operate the heating/cooling unit signal has reached
to the Receiver.
Operating Temperature Range
Battery Life
Operating Temperature
Storage Temperature
(5oC) – (30oC)
1 Year (2 x AAA)
(-10oC) – (+50oC)
(-20oC) – (+60oC)
The devicesshould not be mounted on metalsurfaces.
The devices should not be installed close to electrical cables and
electronic equipment such ascomputers and televisionunits.
The devices should not be installed near large metal structures or other
building materials using fine metal meshes such as special glass or
special concrete.
FACTORY SETTINGS RESET
3 Short Orange
Blinking
You can reset your Room Thermostat to its default factory settings. This
operation resets the mode temperature values, calibration setting and
heating/coling modes to factory setting. To reset your Room Thermostat to
factory setting:
Steady Orange
3 Short Green
Blinking
Heating/cooling unit is operating.
Shut the heating/cooling unit down signal has
reached to the Receiver.
Receiver
Dimensions
Operation Current
Relay NO Switching Current
90mm / 90mm / 25mm
230V AC
7A (240VAC – Resistive load)
10A (120VAC – Resistive load)
(-20oC) – (+60oC)
Blinking Orange
Heating/Cooling unit operates in manual mode.
While your device is turned off, press and hold the "On/Off"button for 3
seconds.
Distance between the Room Thermostat and the Receiver should not
exceed 20metersor 2 floors.
Blinking Red
Receiver did not get any signal from the Room
Thermostat for 22 minutes or longer.
Heating/cooling unit has shut down.
Pressthe“On/Off” button until “
While in the “ ” menu, select the “
and press the“On/Off” button.
Your devicewill be turned off and resetto factory settings.
” menu appears.
Receiver must be installed at least 50 cm away from the heating/cooling
unit.
” option by using “+” or “-” buttons
Storage Temperature
ROOMTHERMOSTATPLACEMENT
RECEIVERSETUP
ROOMTHERMOSTAT
Buttons Functions
Room Thermostat needs to be placed in the room which is used most
frequently. For instance; living room or lounge. Placing the Room
Thermostat in a spot that have air circulation like entrance of a room or side
of window should be avoided. Also anywhere close to heating/cooling units
such as radiator, stove and spots which get direct sun lights would not be
suitable. Room Thermostat needs to be located above the floor 150 cm
height. Fewtrialsmaybe made to find themost convenientspot.
First, shut down your heating/cooling unit and your heating/cooling unit's
power sourcewith allelectricalcurrent(fuse, socketetc.)
As shown in the connection diagram, connect one end of the heating /
cooling unit connection cable to the COM and the other to the NO input of
the Receiver.
MODESETTINGS
There are 2 modes in the Room Thermostat. These are Comfort Mode “
”
and Economy Mode “ ”. Modes work according to the pre-set temperature
valuesadjusted byuser.
1
2
In order to change the comfort mode temperaturevalue;
Connect the other ends of the cable -which you connected to the Receiver
to room thermostat connection terminal as shown in your heating /
cooling unit's user manual.
Pressand hold thecomfort mode button for 3 seconds.
Change the temperaturevaluebypressing “+” or “-“ buttons.
Press the comfort mode button once to save the changes you have made
or wait10seconds.
3
4
5
You must first connect the Receiver power cable to the Receiver and then
to the fuse to which the heating/cooling unit is connected.
After completing the cable connection process, firstly turn on your fuse
and then yourheating/cooling unit.
6
In order to change theeconomy mode temperature value;
Press and hold theeconomy mode button for 3 seconds.
Change the temperaturevaluebypressing “+” or “-” buttons.
Press the economy mode button once to savethe changes youhavemade
or wait10seconds.
By pressing the Receiver's manual usage button for 2 seconds, youshould
see the Orange Light blinking on the Receiver. In this way, after making
sure that the heating/cooling unit is operating, press the same button
again for 2 seconds and seethattheOrangeLEDturns off.
Set up the Room Thermostat to pair the Receiver with the Room
Thermostat.
1
2
3
4
5
6
Economy Mode
Temperature Adjustment (Increasing)
Comfort Mode
Heating/Cooling Modes
Temperature Adjustment (Decreasing)
ON/OFF and Setting Button
You can use the “+” and “-” buttons to use the Room Thermostatmanually.
1
2
3
4
| General | Details |
|---|---|
| Name | GENERAL LIFE NORA 270S RF Digital Room Thermostat User Manual |
| Make | GENERAL LIFE |
| Language | English |
| Filetype | PDF (Download) |
| File size | 2.26 MB |

GENERAL LIFE HT330S RF Room Thermostat User Manual

GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual

GENERAL LIFE HT250 RF Digital Room Thermostat User Manual

GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual

GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual

GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual

GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual

GENERAL LIFE HT220S RF Digital Room Thermostat User Manual

GENERAL LIFE 270S RF Room Thermostat User Manual

GENERAL LIFE 270 Wireless Room Thermostat User Manual

GENERAL LIFE NORA 270S RF Digital Room Thermostat User Manual Overview
Summary of Contents
- Page 1: - NORA 270S RF is a wireless room thermostat that allows users to adjust room temperature for comfort and economic heating/cooling. - Different mode options include Comfort Mode and Economy Mode. - The heating indicator shows whether the heating unit is working or not. - Pairing the room thermostat with the receiver involves pressing the sync button on the receiver. - Battery placement requires inserting two new AAA alkaline batteries in the correct direction. - Calibration may be necessary to ensure accurate temperature readings compared to other thermometers. - The receiver must be installed away from heating/cooling units and should not be mounted on metal surfaces. - The device should be placed in a frequently used room, avoiding areas with direct sunlight or close proximity to heating/cooling units. - The room thermostat has two modes: Comfort Mode and Economy Mode, which can be adjusted by the user. - A factory settings reset can restore the thermostat to its default configuration.
- Page 2: Warranty conditions state that the warranty period starts from the invoice date and covers manufacturing defects for 5 years. The room thermostat sends a status signal to the receiver every 6 minutes to ensure synchronized operation. If the signal is lost for 22 minutes, the heating/cooling operation stops for safety. The TPI algorithm predicts temperature changes to maintain the desired temperature with minimal deviations. Devices are delivered in working condition, and on-site commissioning incurs a service fee. Repairs under warranty are conducted at the company factory, and transportation costs are the customer's responsibility. Malfunctions caused by customer misuse are not covered by the warranty. The learning process for TPI thermostats restarts if the placement is changed or if the device is de-energized. The warranty document must be retained by the customer, and a replacement will not be issued if lost. Customers can appeal to consumer courts for complaints regarding warranty issues.