MODEL TH110A-DP-P
B
B
240 VAC
SUMMARY
u
60 HZ
OPTIONS SELECTION
B
At the back of the thermostat, there are 3 selection switches to set at
your preferences.
Temperature in °C or °F, time in 12 or 24 hours and Early Start function.
u
u
TO SET TIME AND DAY
Press on DAY, HOUR and MIN buttons to adjust time and day.
NOTE: All cables and connections must conform to the local electrical code.
TO RECORD THE
Select chosen setpoint temperature by using
button (app. 3 seconds) until icon appears on display.
(COMFORT) SETPOINT TEMPERATURE
WARNING: Special CO/ALR solderless connectors must be used when
connecting with aluminum conductors.
or button. Press on
Power-up
u
u
TO RECORD THE
Select chosen setpoint temperature by using
Press on button (app. 3 seconds) until icon appears on display .
(ECONOMY) SETPOINT TEMPERATURE
or button.
Set the On/Off switch to On.
When power is applied for the first time, the
display must show the time 00:00, the room
TO RECORD THE
To program the Vacation temperature, select the desired degree using the
buttons and press on the and buttons simultaneously
icon is displayed (app. 3 seconds).
(VACATION) SETPOINT TEMPERATURE
temperature and the Manual mode icon (
).
Other information might show up on the display if
installation is defective or does not comply with the
instructions.
until the
u
OPERATING MODES
To select an operating mode, use MODE button.
NOTE: The On/Off switch set to Off will place the
thermostat in sleep mode. Ideal for sum-
mertime.
AUTO:
Runs the program.
and can override temporarily your programming up to the
next program.
or
shows temperature setting
MAN:
Maintains the selected temperature.
the temperature setting.
or
changes
OPERATING MODES
The TH110A-DP-P has two (2) operating modes.
MANUAL (
)
This mode allows you to maintain a constant temperature in the room.
1- To activate this mode, press on Mode button to display the icon.
2- Set the desired temperature using the
buttons or select the
simultaneously.)
pre-programmed
(To select the
or
or
settings.
and
setting, press on
AUTOMATIC (
This mode executes your own programming.
To activate this mode, press on Mode button to display the
The or icon indicates which temperature setting is used. Also, the icon
)
icon.
of the program number will be shown.
Memory back-up
In the event of a power failure, an internal circuit will maintain the programming
and the time. But only the time could have to be set if power failure is more than
2 hours.
Early Start function
The thermostat is providing a built-in function enabling it to calculate the
optimum time to start the heating system to achieve the desired temperature
setting at the programmed time. This function could start the heating system as
early as 6 hours prior to the programmed time. To enable this function, set the
switch E.S. to “ON” at the back of the thermostat.
PROGRAMMING
Programming the time and day
INSTALLATION
1- Set the time using the Hour and Min buttons.
2- Set the day using the Day button.
NOTE: The "Problems and Solutions" section at the end of this user's guide will
help you to correct your problems during the installation.
Programming the Comfort, Economy and Vacation settings
This thermostat has been designed to operate with any installation
which has a RESISTIVE load not exceeding 4000 W (16.67 A) @ 240 VAC
such as electric baseboards, radiant ceilings and floors, electric con
vectors, etc. It is not compatible with a low voltage controller used by
a central heating system.
The Comfort
the temperatures that you wish to have during the day
are away at work
, Economy
and Vacation
settings respectively represent
, at night or while you
.
, or while you are away for an extended period
Electricians or experienced technicians should install the thermostat.
This thermostat is designed to be used with a self-protected heating
system equipped with thermal cut off and circuit breaker.
PARTS INCLUDED
- One (1) TH110A-DP-P (240 VAC) thermostat
- Two (2) 6-32 screws
- Four (4) solderless connectors (for copper wire)
TURN OFF POWER OF THE HEATING SYSTEM AT THE MAIN POWER
PANEL TO AVOID ELECTRICAL SHOCK. Keep air vents of the thermostat clean
and free from obstructions.
920-110-003-00-1-A 1/2
| General | Details |
|---|---|
| Name | aube technologies TH110A-DP-P Thermostat User Manual |
| Make | aube technologies |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.41 MB |

aube technologies TH108PLUS Electronic Thermostat User Guide

aube technologies TH104PLUS 5-2 Day Programmable Electric Thermostat Owner’s Manual

aube technologies TH115-AF-GA Programmable Thermostat Owner’s Manual
aube technologies CT230-120GA Slave and Master Thermostat Instruction Manual

aube technologies TH150 Series VAV Thermostat User Guide

aube technologies TH104PLUS Programmable Thermostat Owner’s Manual

Aube TH110A-DP-P Manual: Questions and Answers
How do I set the time on the Aube TH110A-DP-P thermostat?
Use the Hour and Min buttons to adjust the time.
- Press Hour button to set hours.
- Press Min button to set minutes.
- Press Day button to set the day. User Manual, p. 1
Can the Aube TH110A-DP-P work with my central heating system?
No, it is not compatible with low voltage controllers used by central heating systems. The Aube TH110A-DP-P is designed for resistive loads not exceeding 4000 W at 240 VAC, such as electric baseboards and radiant heating. User Manual, p. 1
What is the difference between Auto and Manual modes on the Aube TH110A-DP-P?
| Mode | Function |
|---|---|
| Manual | Maintains a constant selected temperature in the room |
| Automatic | Executes your own programming schedule |
What does the Early Start function do on the Aube TH110A-DP-P?
It calculates the optimum time to start heating and achieve your desired temperature at the programmed time, starting up to 6 hours early. Enable it by setting the E.S. switch to ON at the back. User Manual, p. 1