How do I connect wires to the Milesight WT201-868M terminals?
Insert wires into the terminal holes on the wiring backplate until firmly in place.
- Hold down the tabs on each terminal.
- Push the wire into the corresponding hole until it sits firmly.
- Gently tug the wire to confirm it is securely connected.
- If you need to remove a wire, hold down the terminal tab again. User Guide, p. 9
Can I use the Milesight WT201-868M without a C wire if I don't have a Power Extension Kit?
No. If there is no C wire, you must add a Power Extension Kit to power the thermostat. User Guide, p. 6
How do I set up the Milesight WT201-868M after wiring it to my HVAC system?
Adjust the DIP switch and configure the device using NFC or USB.
- Adjust the DIP switch: set to Only RC if only the RC wire is connected, or RC & RH if both RC and RH wires are connected.
- Push the thermostat into the wiring backplate and ensure it is securely fixed.
- Turn on your heating and cooling systems to verify the thermostat powers on.
- Download Milesight ToolBox and configure the device using NFC or USB.
- Test the buttons to confirm proper function. User Guide, p. 9
What is the maximum current the Milesight WT201-868M power supply can handle?
24VAC with a maximum of 2A current, though prolonged operation at maximum current will damage the device. User Guide, p. 8
Where are the terminal connections located on the Milesight WT201-868M?
Terminals are on the wiring backplate. Common labels include CL, CN, RC, RH, W1, W2, AUX, E, Y1, Y2, GL, G, GH, C, O/B, and PEK for the Power Extender Kit connection. User Guide, p. 4
What do I do if my system has no C wire for the thermostat?
Connect a Power Extension Kit to the PEK terminal. The kit provides the necessary power when a C wire isn't available. User Guide, p. 5