Milesight WT201-868M Smart Thermostat User Guide
SMART THERMOS
Cloud App
Quick Start Guide
All Software & files can be downloaded from
Xiamen Milesight IoT Co., Ltd.
Add:Building C09, Software Park Phase III, Xiamen 361024,Fujian,China
Make Sensing Matter
WT201-868M / 915M
| General | Details |
|---|---|
| Name | Milesight WT201-868M Smart Thermostat User Guide |
| Make | Milesight |
| Language | English |
| Filetype | PDF (Download) |
| File size | 1.34 MB |

Milesight WT201 Airteq Smart Thermostat User Guide

Milesight WT101 Smart Radiator Thermostat User Guide

Milesight WT201 Smart Thermostat User Guide

Milesight WT30x Smart Fan Coil Thermostat User Guide

Milesight WT201-868M Smart Thermostat User Guide Overview
Summary of Contents
- Page 1: SMART THERMOS Quick Start Guide All software and files can be downloaded from the resources download center. Make sensing matter.
- Page 2: Packing list Hardware introduction Wiring diagrams Installation Configuration guide FCC statement
- Page 3: Packing list includes various components such as a DIP switch, Type-C USB, wiring backplate, decorative cover plate, WT201 device, child lock, thermostat, wire label sticker, wall mounting kits, and a fixing screw. The hardware introduction section describes the network status indicator, reboot process, and button functions. Network status is indicated by blinking for inactivated and static on for activated. Rebooting the device involves pressing and holding button 1 and button 5 for more than 3 seconds. Button functions include system on/off, temperature adjustment, fan mode, and temperature control mode. Resetting to factory default requires pressing and holding button 1 and button 5 for more than 10 seconds. The NFC area is also mentioned in the hardware introduction. A quick start guide and warranty card are included in the packing list. Temperature control modes and fan modes are specified. Target temperature settings are part of the control plan.
- Page 4: Wiring examples Wiring diagrams Furnace + air conditioner Live line out of keycard switch Neutral line of keycard switch Power of cooling system and heating system (24VAC) Heating/The first stage of heating The second stage of heating/Auxiliary heating Emergency heating used on very cold days Connect Power Extender Kit when there is no C wire.
- Page 5: Furnace (2 stage) + Air Conditioner (2 stage) If there is no C wire, it is necessary to add a Power Extension Kit. Power Extension Kit
- Page 6: Heat pump with auxiliary heat If there is no C wire, it is necessary to add a Power Extension Kit. Power Extension Kit
- Page 7: If there is no C wire, it is necessary to add a Power Extension Kit. Connect to W1 if there is only one W wire on boiler. Boiler + Air Conditioner Air Handler + Aux Furnace Heat Pump Air Conditioner
- Page 8: Remove the mounting plate of the old thermostat. Ensure the wires do not fall into the holes. Press the wiring backplate to the decorative cover plate to fix them together. It is suggested to use a decorative cover plate to cover the holes left on the wall by the old thermostat. Pass the wires through the hole in the middle of the wiring backplate. Fix the wiring backplate (and decorative cover plate) to the wall using wall plugs and wall mounting screws. Ensure the circuit of all related systems are shut off before installation. Remove the old thermostat from the wall and check if the power supply is 24VAC with a 2A maximum current. Do not power the WT201 thermostat with maximum current for a long time, which will damage the device. Disconnect the wires from the old thermostat and label the wires with stickers.
- Page 9: Hold down on the tabs to insert the wires into the holes of the corresponding terminals on the wiring backplate until they are firmly in place. If you need to release the wires again, hold down the terminal tabs. Adjust the DIP switch on the WT201 thermostat based on the connected wires. Download “Milesight ToolBox” App on an NFC-supported smartphone. Open “Milesight ToolBox” App and place the NFC area of the smartphone to the device. It’s suggested to change the default password for security reasons. Push the WT201 thermostat into the wiring backplate gently and ensure both parts are securely fixed. Turn on the systems to check if the WT201 thermostat is on. Download the ToolBox software from Milesight’s official website. Connect the WT201 device to a Windows computer via a type-C cable.
- Page 10: This device complies with Innovation, Science and Economic Development Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Open the ToolBox software, select type as “General” and the serial port as USB port, then type the login password (Default password: 123456) to login to the device. It’s suggested to change the default password for security reasons. Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This equipment complies with ISED radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. If this equipment does cause harmful interference to radio or television reception, the user is encouraged to try to correct the interference by one or more of the following measures: reorient or relocate the receiving antenna, increase the separation between the equipment and receiver, connect the equipment into an outlet on a circuit different from that to which the receiver is connected, consult the dealer or an experienced radio/TV technician for help. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.