Honeywell RLV4305 Programmable Thermostat Owner’s Manual
Programmable
Thermostat
RLV4305A1000
Owner’s Manual
Read and save these
instructions.
For help please visit
honeywellhome.com
Application
This thermostat is designed to control an electric heating system such as a baseboard
heater, a radiant ceiling, a convector or a fan-forced heater.
The thermostat CANNOT be used with:
• a resistive load under 0.83 A
• a resistive load over 14.6 A
• a system driven by a contactor or a relay (inductive load)
• a central heating system.
WARNING Electrical Shock Hazard.
This thermostat is a line voltage control (120–240 Volts). Do not install it if you
are not completely familiar with house wiring. If handled improperly, there is risk
of electric shock hazard, which may cause serious injury or death.
Do you need assistance? We are here to help.
Call 1-800-831-2823 for wiring assistance before returning the
thermostat to the store.
| General | Details |
|---|---|
| Name | Honeywell RLV4305 Programmable Thermostat Owner’s Manual |
| Make | Honeywell |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.53 MB |

Honeywell T6 Pro Programmable Thermostat User Manual

Honeywell D1-528 Direct Thermostat Installation Guide

Honeywell FocusPRO P200 Programmable Thermostat User Guide

Honeywell RCHT8610WF Series Smart Thermostat Installation Guide

Honeywell T9 Smart Thermostat Installation Guide

Honeywell TH2320WF4011 FocusPRO Smart S200 Series Thermostat User Guide

Honeywell TL116A Thermostat Installation Guide

T10 Pro Smart Thermostat with Redlink Room Sensor

Honeywell TH6320WF2003 Lyric T6 Pro Wi-Fi Programmable Thermostat User Guide

Honeywell RTH9580 Wi-Fi Color Touchscreen Programmable Thermostat User Guide

Honeywell RLV4305 Programmable Thermostat Owner’s Manual Overview
Summary of Contents
- Page 1: Programmable thermostat RLV4305A1000 owner’s manual. This thermostat is designed to control an electric heating system such as a baseboard heater, a radiant ceiling, a convector, or a fan-forced heater. The thermostat cannot be used with a resistive load under 0.83 A, a resistive load over 14.6 A, a system driven by a contactor or a relay, or a central heating system. Warning: Electrical shock hazard. This thermostat is a line voltage control (120–240 Volts). Do not install it if you are not completely familiar with house wiring. If handled improperly, there is a risk of electric shock hazard, which may cause serious injury or death. For wiring assistance, call for help before returning the thermostat to the store.
- Page 2: Attention: mercury recycling notice This product does not contain mercury. However, this product may replace a product that contains mercury. Mercury and products containing mercury should not be discarded in household trash. Caution: electronic waste notice The product should not be disposed of with other household waste. The correct disposal of end-of-life equipment will help prevent negative consequences for the environment and human health. Supplied parts One thermostat, two 6-32 mounting screws, two solderless connectors. Installation Turn off power to the heating system at the main power panel to avoid electrical shock. All cables and connections must comply with local electrical codes. Install the thermostat about 5 ft. (1.5 m) high, on an inside wall facing the heater. Avoid locations where there are air drafts, dead air spots, or direct sunlight. The thermostat wires are not polarized; either wire can be connected to the load or to the power supply.
- Page 3: Connect the thermostat wires to the power and to the load using solderless connectors for copper wires. Push the excess wires back inside the electrical box. Secure the thermostat to the electrical box using the provided screws. Insert the screws through either the right or left pair of mounting holes on the thermostat. If there is a protective film or sticker on the thermostat’s screen, peel it off. Apply power to the heating system. Verify the installation by checking that the heater can be turned on by raising the setpoint using the Up button and off by lowering the setpoint using the Down button. Keep the thermostat’s air vents clean and free from obstructions.
- Page 4: Clock and day setting Press the Day button to set the day. Use the Hour and Min buttons to set the clock. The clock must be set when the time is incorrect or flashes on the screen. Press the button to exit. Controls Day button Hour button Minute button Program button Return button Backlit screen Mode button Up and Down buttons The screen is backlit for 12 seconds when you press any button.
- Page 5: Display shows time and day, setpoint temperature, and room temperature. The thermostat indicates if settings are locked and if it is configured for a fan-forced heater. In Automatic mode, the thermostat adjusts its temperature setpoint according to the period of the day. You can program up to 4 periods in a day with different settings for weekdays and weekends. The default schedule includes specific start times and temperatures for Wake, Leave, Return, and Sleep periods. Temporary Override allows modification of the setpoint temperature while in Automatic mode. The new setpoint will be used until the beginning of the next period during an override. Auto flashes on the screen during the override. You can cancel the override by pressing a button. The thermostat displays the set temperature for 5 seconds when the Up or Down button is pressed.
- Page 6: To modify the schedule, press the Pgm button. Each time you press the Pgm button, the thermostat displays one of the periods of the schedule in the following order: Weekdays (MO TU WE TH FR) and Weekend (SA SU). Press the Hour and Min buttons to set the start time of the displayed period. To cancel the period, press the Mode button. Press the Up or Down button to set the temperature. To set another period, press the Pgm button and repeat steps 2 and 3. To place the thermostat in Manual mode, press the Mode button until Man appears on the screen. In Manual mode, any modification to the temperature setpoint must be done manually. To place the thermostat in Away mode, press the Mode button until Away appears on the screen. This mode is a quick way to lower the temperature to a predetermined setting before you go away for an extended length of time. To disable heating, press the Mode button until Standby appears on the screen. In Standby mode, the setpoint temperature cannot be displayed or modified.
- Page 7: The first parameter appears when the menu is displayed. Press the Pgm button for 3 seconds to access advanced settings. To display the next parameter, press the Pgm button. To modify the displayed parameter, press the Up or Down button. To exit the menu, press the button or do not press any button for 1 minute. Temperature unit options are °F / °C, with the default setting being °F. Time format options include 12 hr / 24 hr, with a default of 12 hr. Away temperature is set to 59°F (15.0°C) by default. Daylight saving time can be set to On or Off. Keypad lock can be set to On or Off.
- Page 8: Away temperature allows you to set the desired temperature for Away mode. Daylight Saving Time function automatically adjusts the thermostat on specific dates. Year, Month, Day parameters are available only if Daylight Saving Time is enabled. Early Start feature determines when heating begins to reach the desired temperature at the start of Wake and Return periods. Keypad lock restricts settings changes, allowing only temperature viewing. Most problems with the thermostat require little attention and can be traced to specific issues. If the thermostat is hot, ensure the heater capacity does not exceed its maximum load. Wrong temperature display may occur due to drafts or proximity to heat sources. If the thermostat shows the wrong time, it may have lost power for over five hours. Temperature changes may not occur if the thermostat is not in Automatic mode or if the schedule settings are incorrect.
- Page 9: LO is displayed. The measured temperature is below the display range. Heating is activated. HI is displayed. The measured temperature is above the display range. E1, E2 is displayed. The thermostat performance is reduced due to a sensor error. Resetting the thermostat (default settings). All parameters, except the clock, return to their default settings when the thermostat is reset. During a power outage, the thermostat display remains lit for the first 2 minutes. The settings are stored in memory. If the power failure has exceeded 5 hours, the clock and date must be re-adjusted. Specifications: Supply: 120/240 VAC, 60 Hz. Minimum load: 0.83 A (resistive only). Maximum load: 14.6 A (resistive only). Display range: 32 °F to 99 °F (0 °C to 50.0 °C).
- Page 10: ICES-003 Class B Notice This Class B digital apparatus complies with Canadian ICES-003. 1-year limited warranty Resideo warrants this product, excluding battery, to be free from defects in the workmanship or materials, under normal use and service, for a period of one (1) year from the date of first purchase by the original purchaser. If at any time during the warranty period the product is determined to be defective due to workmanship or materials, Resideo shall repair or replace it (at Resideo’s option). This warranty does not cover removal or reinstallation costs. Resideo’s sole responsibility shall be to repair or replace the product within the terms stated above. Resideo shall not be liable for any loss or damage of any kind, including any incidental or consequential damages resulting from any breach of any warranty. This warranty is the only express warranty Resideo makes on this product. The duration of any implied warranties, including the warranties of merchantability and fitness for a particular purpose, is hereby limited to the one-year duration of this warranty. This warranty gives you specific legal rights, and you may have other rights which vary from state to state. If you have any questions concerning this warranty, please write Resideo Customer Relations.
- Page 11: Termostato programable RLV4305A1000 manual del propietario. Lea y guarde estas instrucciones. Este termostato está diseñado para controlar un sistema eléctrico de calefacción. El termostato no se puede utilizar con una carga resistiva inferior a 0.83 A. El termostato no se puede utilizar con una carga resistiva superior a 14.6 A. El termostato no se puede utilizar con un sistema accionado por un contactor o un relé. WARNING: Riesgo de descarga eléctrica. No lo instale si no conoce bien el cableado de su hogar. La manipulación incorrecta de este termostato puede causar riesgos de descargas eléctricas. Llame al 1-800-831-2823 para obtener asistencia con el cableado.
- Page 12: atención: aviso para el reciclaje del mercurio Este producto no contiene mercurio. Sin embargo, este producto puede reemplazar uno que contenga mercurio. El mercurio y los productos que contengan mercurio no se deben desechar con los desperdicios domésticos. Para más información sobre cómo y dónde reciclar adecuadamente un termostato que contenga mercurio en los Estados Unidos, consulte con Thermostat Recycling Corporation. El producto no debe desecharse junto con otros residuos domésticos. Busque el centro de recolección autorizado más cercano o empresas de reciclaje autorizadas. Desechar correctamente los equipos cuya vida útil terminó ayudará a prevenir las posibles consecuencias negativas en el medioambiente y en la salud de las personas. Corte la energía eléctrica al sistema de calefacción en el panel de alimentación principal para evitar una descarga eléctrica. Los cables y las conexiones deben cumplir con los códigos de electricidad locales. Instale el termostato a, aproximadamente, 5 pies (1.5 m) de altura, en una pared interior y orientado hacia el calentador.
- Page 13: Conexiones Conecte los cables del termostato al suministro eléctrico o a la carga utilizando conectores sin soldadura para cables de cobre. Instalación del termostato Empuje los cables sobrantes dentro de la caja eléctrica. Use los tornillos incluidos para sujetar el termostato a la caja eléctrica. Inserte los tornillos en el par de orificios de montaje ubicados a la derecha o izquierda del termostato. Si hay una película protectora o una etiqueta adhesiva en la pantalla del termostato, retírela. Conecte la energía del sistema de calefacción. Compruebe la instalación controlando que el calentador se pueda encender y apagar. Mantenga los conductos de ventilación del termostato limpios y sin obstrucciones.
- Page 14: Configuración de hora y día Presione el botón Day para configurar el día. Use los botones Hour y Min para configurar el reloj. Presione el botón para salir. El reloj se debe configurar cuando la hora sea incorrecta o destelle en la pantalla. Controles Botón de día Botón de hora Botón de minutos Botón de programación Botón Intro Pantalla con luz de fondo Botón de modo Botones de ajuste arriba y abajo
- Page 15: Visualizador Día y hora Temperatura del punto de ajuste Aparece cuando se corta la energía al termostato Indica que las configuraciones están bloqueadas Aparece si el termostato está configurado para calentador impulsado por ventilador Temperatura ambiente Indicador de modo Modo automático El termostato regula el punto de ajuste de la temperatura según el momento del día. Puede programar hasta 4 períodos en un día.
- Page 16: Para modificar el cronograma, presione el botón Pgm (programación). El termostato muestra uno de los períodos del cronograma en el siguiente orden: días de la semana (MO TU WE TH FR) y fines de semana (SA SU). Presione los botones Hour (hora) y Min (minutos) para configurar la hora de inicio del período mostrado. Para cancelar el período, presione el botón Mode (modo). Durante el funcionamiento, el termostato omitirá ese período. Para poner el termostato en modo manual, presione el botón Mode hasta que aparezca Man (manual) en la pantalla. Cualquier cambio en el punto de ajuste de la temperatura se debe efectuar manualmente. Para poner el termostato en modo ausente, presione el botón Mode hasta que aparezca Away (ausente) en la pantalla. Este modo es una manera rápida de reducir la temperatura hasta una configuración predeterminada. Para desactivar la calefacción, presione el botón Mode hasta que aparezca Standby (en espera) en la pantalla.
- Page 17: El primer parámetro aparece cuando se muestra configuraciones avanzadas. Presione el botón Pgm (programación) durante 3 segundos. Para visualizar el siguiente parámetro, presione el botón Pgm (programación). Presione el botón de ajuste arriba o abajo para modificar el parámetro mostrado. Para salir del menú, presione el botón o no presione ningún botón durante 1 minuto. Opciones predeterminadas incluyen unidad de temperatura en °F / °C. Formato de horas puede ser 12 hr / 24 hr. Temperatura en ausente tiene un rango de 41°F - 86°F (5.0°C - 30.0°C). Horario de verano está configurado como Off (desactivado). Elija Yes (sí) si tiene un calentador impulsado por ventilador.
- Page 18: Temperatura en ausente Configure la temperatura que desea tener cuando el termostato esté en modo Away (ausente). Horario de verano Cuando la función de horario de verano está On (activada), el termostato cambia automáticamente al horario de verano el segundo domingo de marzo, y al horario normal el primer domingo de noviembre. Año, mes, día Estos parámetros están disponibles únicamente si la función de horario de verano está On (activada). Arranque anticipado El arranque anticipado se usa únicamente en modo automático. Cuando el arranque anticipado está On (activado), el termostato determina cuándo arrancar la calefacción para que se alcance la temperatura deseada al inicio de los períodos Wake (despertar) y Return (regresar). Bloqueo del teclado Las configuraciones están bloqueadas. Los botones de ajuste de la temperatura únicamente permiten ver el punto de ajuste de la temperatura. Localización y solución de problemas Si tiene dificultades con el termostato, intente seguir las sugerencias que se indican a continuación. La mayoría de los problemas pueden corregirse rápida y fácilmente. El termostato está caliente. Esto es normal. Asegúrese de que la capacidad del calentador no supere la carga máxima del termostato. Se muestra una temperatura incorrecta. Corríjala si se presenta cualquiera de las siguientes situaciones: el termostato está expuesto a una corriente de aire o está ubicado cerca de una fuente de calor. La temperatura no cambia en función del cronograma programado. Compruebe que el termostato esté en modo automático y revise las configuraciones del reloj y el cronograma.
- Page 19: No se pueden modificar las configuraciones. Las configuraciones están bloqueadas. Aparece en pantalla LO. Aparece en pantalla HI. La temperatura medida es inferior al margen de visualización del termostato. La calefacción está encendida. El rendimiento del termostato es reducido debido a un error del sensor. Reinicio del termostato (configuraciones predeterminadas). Durante un corte de energía, la pantalla del termostato permanece encendida durante los primeros 2 minutos. Las configuraciones se guardan en la memoria.
- Page 20: Aviso de clase B según la normativa ICES-003. Este aparato digital de clase B cumple con la normativa canadiense ICES-003. Garantía limitada de 1 año. Resideo garantiza que este producto, excluyendo la batería, no tiene defectos en la mano de obra ni en los materiales en condiciones de uso y servicio normales durante un período de un (1) año desde la fecha de compra. Si el producto está defectuoso, devuélvalo con una factura de venta o llame al Servicio de atención al cliente de Resideo. Esta garantía no cubre los gastos de remoción ni de reinstalación. La única responsabilidad de Resideo será la de reparar o reemplazar el producto según los términos mencionados. Resideo no será responsable por la pérdida o el daño de ningún tipo, incluyendo los daños accidentales o resultantes. Esta garantía es la única garantía expresa que Resideo otorga sobre este producto. Esta garantía le otorga derechos legales específicos, pero es posible que usted goce de otros derechos que varían de un estado a otro.
































