Honeywell Home RLV3150 Electric Thermostat User Guide
| General | Details |
|---|---|
| Name | Honeywell Home RLV3150 Electric Thermostat User Guide |
| Make | Honeywell Home |
| Language | English |
| Filetype | PDF (Download) |
| File size | 1 MB |











Honeywell RLV3150 Manual: Questions and Answers
Honeywell RLV3150 specifications
| Power supply | 240 VAC, 60 Hz |
| Maximum load | 12.5 A (resistive only) 3000 W @ 240 VAC |
| Setpoint range | 5.0°C to 30.0°C (41°F to 86°F) |
| Display range | 0°C to 50.0°C (32°F to 122°F) |
| Operating temperature | 0°C to 50.0°C (32°F to 122°F) |
| Storage temperature | -20.0°C to 50.0°C (-4°F to 122°F) |
How do I wire the Honeywell RLV3150 to my heating system?
Connect thermostat wires to the heating system load and power supply using either 2-wire or 4-wire installation.
- Loosen the screw underneath the thermostat and separate the faceplate from the wallplate.
- Connect wires to the load and power supply terminals.
- Mount the wallplate to the electrical box using provided screws through the left or right mounting holes.
- Set the configuration switches on the back of the faceplate.
- Reinstall the faceplate and tighten the screw.
- Apply power to the heating system and verify it operates. User Guide, p. 2
Can I use this thermostat with a heating load under 2 amps or with aluminum wiring?
No, it won't work with loads under 2 A. For aluminum wires, you must use special CO/ALR solderless connectors instead of standard ones. User Guide, p. 2
What's the difference between minimum and maximum setpoint on the Honeywell RLV3150?
Minimum setpoint is the lowest temperature the thermostat allows; maximum setpoint is the highest. Minimum cannot exceed maximum, and maximum cannot fall below minimum. User Guide, p. 5
What does a faded display mean on the Honeywell RLV3150?
The heater capacity is probably less than the thermostat's minimum load requirement of 2 A. The thermostat cannot operate below that rating. User Guide, p. 5
What do the Up and Down buttons do on the Honeywell RLV3150?
Pressed together for three seconds, they enter setup menu. Pressed individually, they change options. Pressed together briefly, they advance to the next parameter. User Guide, p. 5
What does it mean when the Honeywell RLV3150 display disappears and reappears after a few minutes?
The thermal circuit breaker on the heater has temporarily opened, usually because the heater is blocked by furniture or curtains and overheated, or the breaker itself is defective or too sensitive. User Guide, p. 5
Honeywell RLV3150 compared with other Honeywell thermostats
| Specification | Honeywell RLV3150 | Honeywell RLV3100 | Honeywell RLV4300 | Honeywell RLV4305 |
|---|---|---|---|---|
| Power supply | 240 VAC, 60 Hz | 240 VAC, 60 Hz | 120/240 VAC, 60 Hz | 120/240 VAC, 60 Hz |
| Maximum load | 12.5 A (resistive only) 3000 W @ 240 VAC | 3000 W | 12.5 A (resistive only) | 14.6 A (resistive only) |
| Setpoint range | 5.0°C to 30.0°C (41°F to 86°F) | 40 to 85°F (5 to 30°C) | 5.0°C to 27.0°C (41°F to 81°F) | 41 °F to 86 °F (5.0 °C to 30.0 °C) |
| Display range | 0°C to 50.0°C (32°F to 122°F) | 32 to 122°F ( 0 to 50°C) | 0°C to 50.0°C (32°F to 99°F) | 32 °F to 99 °F (0 °C to 50.0 °C) |
| Storage temperature | -20.0°C to 50.0°C (-4°F to 122°F) | -4 to 120°F (-20 to 50°C) | -20.0°C to 50.0°C (-4°F to 120°F) | -4 °F to 120 °F (-20 °C to 50 °C) |