SALUS RT100 Electronic Room Thermostat Instruction Manual
| General | Details |
|---|---|
| Name | SALUS RT100 Electronic Room Thermostat Instruction Manual |
| Make | SALUS |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.12 MB |

SALUS IT800 WIFI Smart Thermostat Installation Guide

SALUS 091FLRF Wireless Room Thermostat User Guide

SALUS Thermostat and Smart Plug Installation Guide

SALUS Thermostat Sensor TS600 User Guide

SALUS Programmable Wired Thermostat VS30W/VS30B Installation Guide

SALUS Wired Thermostat Installation Guide

SALUS Wired Digital Thermostat – Non-programmable HTRS230 User Manual

SALUS RT520 Radiator Thermostat User Guide

SALUS RT310 Thermostat User Manual

SALUS Thermostat RT520 User Manual

Salus RT100 Manual: Questions and Answers
Salus RT100 specifications
| Maximum load | 1A inductive |
| Differential | 0.5ºC to 0.8º |
| Operating temperature | 0 ºC to + 50 ºC |
| Storage temperature | - 20 ºC to + 55 ºC |
What temperature range does the Salus RT100 support?
10 ºC to 30 ºC. Instruction Manual, p. 4
How do I install the Salus RT100 and connect its wiring?
Remove the setting dial by pulling it forwards, then undo the case securing screw to access the wiring terminals.
- Remove the setting dial by gently pulling it forwards
- Undo the case securing screw with a small crosshead screwdriver
- Pull the case forwards to remove it
- Pass wiring through the cable entry point
- Strip no more than 8mm of insulation from cable ends
- Connect conductors between 0.5 mm² and 1.5 mm² to the terminals Instruction Manual, p. 5
Can the Salus RT100 be used with volt free heating systems?
Yes. The RT100 is designed specifically for volt free heating applications. Instruction Manual, p. 9
What should I check if my room thermostat stops working?
Verify the temperature has been set correctly. Check that the heating system time switch or programmer is switched on. Instruction Manual, p. 8
Salus RT100 compared with other room thermostats
| Specification | Salus RT100 | Seitron Wi-Time | EPH Controls CP4B | EPH Controls HRT |
|---|---|---|---|---|
| Maximum load | 1A inductive | 3A 250V~ SPDT | 8A 230Vac | 8(3)A 230Vac |
| Differential | 0.5ºC to 0.8º | 0,1°C ..5°C (Default0,2°C) | 0.4˚C | Adjustable from 0.0 – 1.0°C |
| Operating temperature | 0 ºC to + 50 ºC | 0°C .. +40°C | 0 … 45˚C | 0 … 45˚C |