Home > Warmme > Warmme ET-72G(W) Thermostat User Manual

Warmme ET-72G(W) Thermostat User Manual

Event default parameter list  
Home  
Tap OK to confirm.  
Tap OK to return to the real-time temperature interface.  
Step 3: Click ‘Add Device’ or ‘+’ on the top-right to add device.  
Return  
Sleep  
Week  
Wake  
Leave  
8.Readout  
Tempera-  
ture  
Tempera-  
ture  
Tempera-  
ture  
Tempera-  
ture  
This thermostat has the function of calculating the percentage of heating time over a period of time.  
The relevant parameters can be queried through the Readout item.  
Readout query method:  
After entering Settings, tap or ▼ to select Readout.  
Tap OK to enter the selection.  
Start time  
Start time  
Start time  
Start time  
Step 4: Click ‘WiFi thermostat’.  
Mon--Fri  
6:00  
8:00  
78°F  
78°F  
8:00  
8:30  
69°F  
79°F  
17:00  
17:30  
78°F  
78°F  
22:00  
22:00  
69°F  
69°F  
Sat--Sun  
Office  
Step 5: Operate thermostat. If the WIFI icon flash quickly,  
User  
Click ‘Press to connect’.  
Tap or ▼ to select 1Day, 30Days or 365Days to query.  
Tap OK to return to the setting item selection.  
Week  
on-work  
off-work  
Step 6:  
Enter Wifi password, and click ‘Confirm’.  
Tempera-  
ture  
9.Factory reset  
Tempera-  
ture  
manual  
Start time  
Start time  
This thermostat has the function of restoring factory parameters.  
Mon--Fri  
Sat--Sun  
7:00  
7:00  
78°F  
68°F  
18:00  
18:00  
69°F  
69°F  
Factory Reset setting method:  
After entering Settings, tap or ▼ to select Factory Reset.  
Tap OK to enter the selection.  
Tap or ▼ to select Yes or No.  
Tap OK to confirm.  
Step 7: If device added successfully, you can change the device name and set region,  
then, click ‘Done’.  
Attention: If failed, please confirm the Wifi is 2.4G version and check the Wifi  
signals, then, use the ‘AP mode’ in the top right to connect again.  
Settings  
In addition to the above common functions, the thermostat also provides a number of settings for  
more occasions. It should be noted that such settings need to be set by professional technicians  
to avoid damage caused by abnormal settings.  
Tap OK to return to the real-time temperature interface.  
Step 8: You can check the real-time temperature and set temperature etc. at the control  
Settings access method:  
Settings default parameter list  
interface.  
Under real-time temperature interface, tap OK to enter the first level menu, and Mode is flashing.  
Tap or ▼ to select Settings.  
Tap OK to enter Settings.  
NO.  
1
Name  
Time  
Default Parameter  
/
Setting Range  
/
°F  
°C  
Settings contains the following items:  
2
°F/°C  
°F  
1.Time  
00 3950  
01 3600  
02 3700  
Set the current real time and day of the week.  
Note: The WiFi version of the thermostat will automatically update to local time after networking.  
Time setting method:  
3
Sensor Type  
00 3950  
Functions and operation  
On/Off  
Room  
The GFCI Reset button is also the switch button. Press the [Reset] button to switch on and off.  
After entering Settings, tap or ▼ to select Time.  
Tap OK to enter the hour setting for the time.  
Tap or ▼ to select the hour value for the current time.  
Tap OK to enter the minute setting for the time.  
Tap or ▼ to select the minute value for the current time.  
Tap OK to enter the day of the week setting.  
Tap or ▼ to select the day of the week.  
4
Sensor Selection  
Floor  
FLoor  
Room.Limit  
Temporary Override Temperature  
5
6
Calibration  
Location  
0°F  
-9°F -- 9°F  
This function is enabled in the automatic intelligent mode, when the temperature demand changes  
at this moment, the setting temperature is enabled, but the parameters in the Event are not  
changed.  
Home  
Office  
Home  
Yes  
No  
Operation method:  
7
Adaptive  
No  
Under the interface showing the real-time temperature, tap or ▼ to modify the set temperature.  
Tap OK to confirm and return to the interface showing the real-time temperature.  
Tap OK to enter the hour setting for the time.  
8
9
Readout  
/
/
Tap  
multi times to return to the real-time temperature interface.  
Yes  
No  
Factory Reset  
No  
Mode selection  
2. Temp unit  
°F or °C can be selected as the temperature unit.  
Temp Unit setting method:  
After entering Settings, tap or ▼ to select °F/°C.  
Tap OK to enter the selection.  
Tap or ▼ to select the desired temperature unit.  
Tap OK to confirm.  
Tap OK to return to the real-time temperature interface.  
This thermostat provides three operating modes:  
Automatic mode: According to the weekly program, the thermostat automatically adjusts the set  
temperature operation.  
Manual mode: The thermostat runs continuously according to the set temperature.  
Frost protection mode: The temperature controller runs at a lower set temperature. The temperature  
range is set from 41°F to 59°F in this mode. This mode is used when you want to keep your room at a  
lower temperature when you are on vacation.  
Troubleshooting  
E1: Built-in probe failure, please contact your dealer or professional technician.  
E2: External probe failure, please contact your dealer or professional technicia  
Installation  
How to set the mode selection:  
In the interface displaying the real-time temperature, tap OK to enter the first level menu, and  
Mode is flashing.  
Tap OK to enter the mode selection.  
Tap or ▼ to change the mode.  
Tap OK to confirm your selection.  
If you select manual mode or freeze protection mode, you also need to tap or ▼ to set the  
temperature.  
1.Loosen the bottom screw by a Phillips screwdriver. Then  
open the thermostat from the upper right side as shown.  
Note: Screw the nut out of the groove and do not need to  
unscrew it.  
3.Sensor type  
This thermostat can be connected not only to the floor sensor but also to two other  
commonly used floor sensors. When replacing the old thermostat, there is no need to replace the  
floor sensor for easy installation.  
Sensor Type setting method:  
After entering Settings, tap or ▼ to select Sensor Type.  
Tap OK to enter the selection.  
Tap or ▼ to select the type of floor sensor you are currently using.  
Tap OK to confirm.  
Tap OK to return to the real-time temperature interface.  
ET-72G(W) English V1.2  
2. Wire as shown:  
L/N lead: Connect the power cord using the terminal block.  
L1/N1 lead: Use a terminal block to connect the load line.  
IN/SNR terminal:Connect the floor sensor.  
OUT terminal:Connect to IN/SNR of Power Module.  
Tap OK to return to the interface showing the real-time temperature.  
Instruction  
Key lock  
Note: Disconnect the main power supply before wiring.  
If an electric floor heating cable or mat system requires more than 15 Amps, install a power module.  
Wiring diameter: 12 to 22 AWG.  
Install the back  
cover into the  
The ET-72G series thermostats control the floor heating system based on built-in weekly program. The  
weekly program runs in 4 or 2 stages per day, 7 days a week. The default weekly program parameters  
can satisfy most usage scenarios. If your living habits are different, you can also modify the weekly  
program parameters in the thermostat or APP. When there is no one in the house, it is recommended to  
set the temperature down to save energy. Besides, the thermostat has built-in adaptive function. When  
this function acts, the thermostat heats or stops heating in advance of next stage to bring the room  
temperature to the set temperature of the next stage. Please note that after turning adaptive on, the  
thermostat takes a few days to learn the time required.  
The thermostat provides a key lock function to prevent the thermostat setting parameters from  
being incorrectly modified.  
Note: the [Reset] button and the [Test Monthly] button can still operate normally so as to response  
to an emergency.  
No.  
00  
Sensor Type  
3950(default)  
3600  
Parameters  
erminal box and  
secure it with  
the set screw.  
Set the key lock mode:  
1. Under real-time temperature interface, press and hold  
2. Under real-time temperature interface, tap OK to enter the first level menu, and Mode is  
01  
02  
R(25°C)=12kΩ R(10°C)=22.2kΩ  
R(25°C)=10kΩ R(10°C)=19.1kΩ  
until the lock symbol appears.  
3700  
flashing.  
4.Sensor selection  
Tap or ▼ to select Key Lock.  
Tap OK to enter the key lock setting.  
Tap OK to confirm.  
Tap OK to return to the interface showing the real-time temperature.  
Cancel the key lock mode:  
In addition to the floor sensor, this thermostat has built-in sensors to detect room temperature.  
Therefore, three sensor applications are available:  
Symbols  
Room: Controls room temperature based solely on built-in sensors.  
Floor: Controls the floor temperature based solely on the floor sensor.  
Room.Limit: Controls the room temperature based on the built-in sensor while monitoring the floor  
temperature not to exceed the upper limit. This application, like Floor, can be used in places such as  
wood floors where floor temperature is critical.  
Under real-time temperature interface, press and hold  
disappears.  
until the lock mark on the screen  
4. Fit the left side of the front and rear covers as shown
the right again and press the upper half of the right  
border until you hear a click. Use a screwdriver to  
secure the bottom screw. Turn on the power and  
test the GFCI function.  
1 On/Off/GFCI reset button  
2 GFCI test button  
3 Mode  
6 WiFi indicator  
7 Setpoint  
8 Event  
Weekly program parameter setting  
In the automatic mode, the thermostat runs automatically according to the setting parameters of the  
Sensor Selection setting method:  
After entering Settings, tap or ▼ to select Sensor Selection  
Tap OK to enter the selection.  
Tap or ▼ to select the sensor application type.  
Tap OK to confirm.  
Tap OK to return to the real-time temperature interface.  
.
weekly program. The weekly program parameters contain two parameters: Schedule and Event.  
4 Temperature  
5 Sensor selection  
9 Day and time  
10 Touch key  
1. Schedule  
WARNINGS  
Assign seven days a week to the following two schedules:  
5+1+1: The Event parameter is the same from Monday to Friday, with separate Event parameters  
on Saturday and Sunday.  
To avoid risk of electric shock, disconnect all power coming to  
heater at main service panel before installation of the thermostat. Keep air vents of thermostat clean  
and free from obstructions. All wiring must conform to local and national electrical codes and  
ordinances. Installation must be carried out by qualified personnel.  
Note: If Room.Limit is selected, you need to set the maximum temperature that the floor can accept.  
7: With separate Event parameters every day.  
5. Calibration  
Schedule parameter setting method:  
Under real-time temperature interface, tap OK to enter the first level menu, and Mode is flashing.  
Tap or ▼ to select Schedule.  
Tap OK to enter the parameter settings.  
Tap or ▼ to select a parameter.  
Tap OK to confirm.  
Ground Fault Circuit Interrupter (GFCI)  
This thermostat has built-in probe and floor sensor calibration function. In the case of demand for  
higher precision  
Calibration setting method:  
After entering Settings , tap or ▼ to select Calibration .  
This thermostat has a built-in GFCI function that protects people from electric shock. It is very  
important to check whether the GFCI function is normal or not every month. Here are the check  
steps:  
Classification  
The thermostat is a Class II device (reinforced insulation) and used for controlling electrical floor  
heating. The product must be connected to the following leads:  
L/N lead: Connect the power cord using the terminal block.  
L1/N1 lead: Use a terminal block to connect the load line(Max 15A).  
Note:  
Tap OK to go to select Room or Floor .  
Tap or ▼ to select Compensate Built-in Probe or Floor Sensor.  
Tap OK to enter the compensation setting.  
Tap or ▼ to adjust the real-time temperature to match the displayed temperature value of the  
calibration instrument.  
Tap OK to return to the setting item selection.  
1. Confirm that the thermostat is turned on.  
2. Press the [Test Monthly] button. If a red light appears in the upper left corner of the  
Tap  
to return to the real-time temperature interface.  
OK  
thermostat and GROUND FAULT appears on the screen, the GFCI function is normal. If there is  
no response, it means the function is invalid, please contact the dealer or electrical installer.  
Note: Do not press and hold the [Test Monthly] button.  
Electric floor heating cable/mat must be in accordance with the supply voltage.  
The terminals are designed to handle a cross-section of wire measuring 12-22AWG.  
2. Event  
In the Home scenario, the day is divided into four events: Wake--  
(In the Office scene, the day is divided into two phases: on work--  
temperature for each stage can be set separately.  
Leave--  
off work-- ). The set  
Return--  
Sleep--  
3. Press the [Reset] button. The red light is off and the screen shows the power off state.  
4. Press the [Reset] button again. The thermostat is turned on.  
Technical specification  
Supply voltage:  
GFCI:  
6. Location  
This thermostat is suitable for use in both homes and offices. For the office, a set of weekly  
program parameters is built in. See the Weekly Program Parameters section for details.  
Location setting method:  
After entering Settings, tap or ▼ to select Location.  
Tap OK to go to select Office or Home.  
Tap or ▼ to select one.  
Event parameter setting method:  
Under real-time temperature interface, tap OK to enter the first level menu, and Mode is flashing.  
Tap or ▼ to select Event.  
Tap OK to enter the week selection.  
Tap or ▼ to select the day you want to modify the parameters.  
Tap OK to enter the stage selection for the day.  
If in daily use, the red light is on and the screen appears GROUND FAULT. Then you need to  
check if the ground fault is present by pressing the [Reset] button. If the red light is off and the  
screen shows the shutdown status, it is nuisance tripping. If not, it means that ground fault has  
occurred. Please contact your dealer or professional technician immediately.  
120/240 VAC 50/60 Hz  
Class A (5 mA trip level)  
Load:  
Setpoint range:  
max.15 A (resistive load)  
+5 to +40°C / +41 to +104°F  
Temperature range: +5 to +45°C / +41 to +113°F  
Dimension(Inch)  
Tap OK to confirm.  
WiFi connection(Only for ET-72GW)  
Tap or ▼ to select the stage that you want to modify the parameters.  
Tap OK to enter the temperature setting of the current phase.  
Tap or ▼ to select the temperature value you want to set.  
Tap OK to enter the hour setting for the start time of the current phase.  
Tap or ▼ to select the hour of the start time.  
Tap OK to enter the minute setting for the start time of the current phase.  
Tap or ▼ to select the minute of the start time.  
Tap OK to return to the stage selection for the day.  
Tap OK to return to the real-time temperature interface.  
Step 1: Scan the QR code or download Warmme from APP store/Google browser.  
7.Adaptive  
This thermostat has an adaptive function. When this function is enabled, the thermostat heats up or  
stops heating in advance so that the next stage comes and the temperature just reaches the set  
temperature.  
Adaptive setting method:  
After entering Settings, tap or ▼ to select Adaptive.  
Tap OK to enter the selection.  
Step 2: Register and log in with mobile number  
or email address in the APP.  
Attention: Please read and agree “Privacy Policy  
and Service agreement” before registration.  
Note: Return to the interface of the real-time temperature and tap  
multiple times.  
Press or ▼ to get Yes or No.  
GeneralDetails
NameWarmme ET-72G(W) Thermostat User Manual
MakeWarmme
LanguageEnglish
FiletypePDF (Download)
File size0.68 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...

Warmme ET-72G(W) Thermostat User Manual
Get the free PDF manual for the Warmme ET-72G(W) Thermostat User Manual and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

Warmme ET-72G(W) Thermostat User Manual Overview

Summary of Contents

  • Page 1: This thermostat has the function of calculating the percentage of heating time over a period of time. The relevant parameters can be queried through the Readout item. After entering Settings, tap ▲ or ▼ to select Readout. Tap OK to enter the selection. This thermostat has the function of restoring factory parameters. Factory Reset setting method: After entering Settings, tap ▲ or ▼ to select Factory Reset. Tap OK to confirm. Settings contains the following items: Time, Sensor Type, Sensor Selection, Calibration, Location. The thermostat provides a key lock function to prevent the thermostat setting parameters from being incorrectly modified. This thermostat has built-in probe and floor sensor calibration function.