ROOM THERMOSTAT PLACEMENT
WIRING DIAGRAM FOR ACTUATOR
ENGLISH
Place your Room Thermostat in a room you use frequently in your
living space. For example; like the hall or living room of your home.
Avoid installing the Room Thermostat in places where there is a lot of
air circulation, such as at the doorway or by the window. Also, do not
place it close to heating units (heater core, fireplace, etc.) and in direct
sunlight. We recommend that the room thermostat is placed at a
height of 150cmfromthefloor.
N
L
L1
N1
UNDERFLOOR HEATING THERMOSTAT
generallife.com.tr
FH105S USER MANUAL
min. 20 cm
GENERAL SPECIFICATIONS
UNDERFLOOR HEATING THERMOSTAT
FH105S is a floor heating room thermostat. User provides more
comfortable and affordable heating by setting needed room
temperature.
SensitiveTemperatureMeasurement
WiredConnection
ON/OFFControl
ACTUATOR
ROOM THERMOSTAT WORKING PRINCIPLE
FH105S
USER MANUAL
As soon as you energize your Room Thermostat, it will start working.
Your Room Thermostat measures the temperature of the
environment it is in every 5 seconds. If the ambient temperature rises
0.5 degrees above the temperature you set, your Room Thermostat
turns off the heating unit, and if it falls below 0.5 degrees, it turns on
theheatingunit.
FH105S AND EQUIPMENTS
230V AC
FH105S Room Thermostat
Dowels and
Screws
WIRING DIAGRAM FOR WIRING CENTER
If the floor sensor measures temperature above 28°C, it turns off the
heatingunit. Thefloor sensoroperatingsensitivityis±1°C.*
Thus, it is ensured that the ambient temperature remains within a
certain range.
N
L
L1
N1
*Externalfloor sensorisonly activewhenitisconnected.
TECHNICAL DATA
Note: If a floor sensor is installed with Room Thermostat, only
GENERAL Life floor sensor should be installed. Otherwise, the
product willbeoutof warranty.
Dimensions ( H / L / W )
Operating Current
85.7mm / 85.7mm / 33.5mm
230V AC
Relay NO Switching Current
7A (240VAC – Resistive load)
10A (120VAC – Resistive load)
0.1oC
ROOM THERMOSTAT WIRING DIAGRAM
Temperature Measurement
Accuracy
Operating Sensitivity
Operating Temperature Range
Operating Temperature
Storage Temperature
1
2
3
4
0.5oC
(5oC) – (30oC)
(-10oC) – (+50oC)
(-20oC) – (+60oC)
WIRING
CENTER
230V AC
ROOM THERMOSTAT
WARNING!
Indicator LED
Set Button
Operations related to the control panel, heating unit or electrical
installation must be carried out by persons with professional
qualifications.
5
N
L
L1
NTC
N1
WARNING!
6
RoomThermostatIndicator LED Descriptions
The assembly of product
should be done according to
the image above.
LED light is on
LED light is off
Heating unit is working
Heating unit is not working
For electrical connection,
please see diagram 5.
Should not be used in case
the usage of a wiring center.
generallife.com.tr
1
2
3
| General | Details |
|---|---|
| Name | GENERAL LIFE FH105S Underfloor Heating Thermostat User Manual |
| Make | GENERAL LIFE |
| Language | English |
| Filetype | PDF (Download) |
| File size | 1.75 MB |

GENERAL LIFE HT330S RF Room Thermostat User Manual

GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual

GENERAL LIFE HT250 RF Digital Room Thermostat User Manual

GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual

GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual

GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual

GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual

GENERAL LIFE HT220S RF Digital Room Thermostat User Manual

GENERAL LIFE 270S RF Room Thermostat User Manual

GENERAL LIFE 270 Wireless Room Thermostat User Manual

GENERAL LIFE FH105S Underfloor Heating Thermostat User Manual Overview
Summary of Contents
- Page 1: Room thermostat placement is crucial for effective operation. The thermostat should be placed in frequently used rooms, avoiding areas with high air circulation or direct sunlight. It is recommended to install the thermostat at a height of 150 cm from the floor. The FH105S is a floor heating room thermostat that allows users to set their desired room temperature. The thermostat measures the ambient temperature every 5 seconds and controls the heating unit accordingly. If the floor sensor detects a temperature above 28°C, it will turn off the heating unit. Only the General Life floor sensor should be used with the Room Thermostat to maintain warranty validity. The operating temperature range for the thermostat is between -10°C and +50°C. All electrical installations should be performed by qualified professionals. The indicator LED provides information on the heating unit's operational status.
- Page 2: warranty certificate declaration of conformity the product marked with CE is covered by the provisions of the mentioned directive. devices and their apparatus are out of warranty if they are beaten, broken, or scratched by the customer. damages resulting from the use of devices belonging to other brands without the approval of the manufacturer are not covered by the warranty. battery leakage and errors due to rust, oxidation, and liquid contact are not covered by the warranty. the warranty period starts from the invoice date and is valid for 2 years against manufacturing defects. the repair of devices covered by the warranty is carried out in the company factory. customers can make complaints and appeals to consumer courts or consumer arbitration committees. the warranty document must be kept by the customer during the warranty period. malfunctions resulting from the use of devices contrary to the user manual are not covered by the warranty.