ROOMTHERMOSTATPLACEMENT  
WIRINGDIAGRAM FORACTUATOR  
ENGLISH  
Place your Room Thermostat in a room you use frequently in your  
living space. For example; like the hall or living room of your home.  
Avoid installing the Room Thermostat in places where there is a lot of  
air circulation, such as at the doorway or by the window. Also, do not  
place it close to heating units (heater core, fireplace, etc.) and in direct  
sunlight. We recommend that the room thermostat is placed at a  
height of 150cmfrom theoor.  
N
L
L1  
N1  
UNDERFLOOR HEATING THERMOSTAT  
generallife.com.tr  
SERIES:  
MITRA, ADEN, ARUNA, CERES, GAIA, ILLONA, NORA, SENNA, TERRA,  
THERMA  
min. 20 cm  
FH10/FH10S USER MANUAL  
UNDERFLOOR HEATING THERMOSTAT  
GENERALSPECIFICATIONS  
FH10/FH10S is a floor heating room thermostat. User provides more  
comfortable and affordable heating by setting needed room  
temperature.  
SensitiveTemperatureMeasurement  
Wired Connection  
ACTUATOR  
SERIES:  
ROOMTHERMOSTATWORKINGPRINCIPLE  
ON/ OFFControl  
MITRA, ADEN, ARUNA, CERES,  
GAIA, ILLONA, NORA, SENNA,  
TERRA, THERMA  
As soon as you energize your Room Thermostat, it will start working.  
Your Room Thermostat measures the temperature of the  
environment it is in every 5 seconds. If the ambient temperature rises  
0.5 degrees above the temperature you set, your Room Thermostat  
turns off the heating unit, and if it falls below 0.5 degrees, it turns on  
theheating unit.  
230V AC  
FH10/FH10SANDEQUIPMENTS  
Room Thermostat  
Dowels and  
Screws  
WIRINGDIAGRAM FORWIRINGCENTER  
FH10/FH10S  
USER MANUAL  
If the floor sensor measures temperature above 28°C, it turns off the  
heating unit. The floor sensor operating sensitivityis ±1°C.*  
Thus, it is ensured that the ambient temperature remains within a  
certain range.  
N
L
L1  
N1  
*Externaloor sensor is only activewhen itis connected.  
Note: If a floor sensor is installed with Room Thermostat, only  
GENERAL Life floor sensor should be installed. Otherwise, the  
product willbe out of warranty.  
TECHNICALDATA  
Dimensions ( H / L / W )  
Operating Current  
Relay NO Switching Current  
85.7mm / 85.7mm / 33.5mm  
230V AC  
7A (240VAC – Resistive load)  
10A (120VAC – Resistive load)  
0.1oC  
ROOMTHERMOSTATWIRINGDIAGRAM  
Temperature Measurement  
Accuracy  
1
2
3
4
Operating Sensitivity  
Operating Temperature Range  
Operating Temperature  
Storage Temperature  
0.5oC  
WIRING  
CENTER  
(5oC) – (30oC)  
(-10oC) – (+50oC)  
(-20oC) – (+60oC)  
230V AC  
ROOMTHERMOSTAT  
WARNING!  
Operations related to the control panel, heating unit or electrical  
installation must be carried out by persons with professional  
qualifications.  
5
Indicator LED  
Set Button  
N
L
NTC  
L1  
N1  
WARNING!  
6
The assembly of product  
RoomThermostatIndicatorLEDDescriptions  
should be done according to  
the image above.  
LED light is on  
LED light is off  
Heating unit is working  
Heating unit is not working  
For electrical connection,  
please see diagram 5.  
Should not be used in case  
the usage of a wiring center.  
generallife.com.tr  
1
2
3
GeneralDetails
NameGENERAL FH10, FH10S Underfloor Heating Thermostat User Manual
MakeGENERAL
LanguageEnglish
FiletypePDF (Download)
File size1.96 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
GENERAL ARUNA 300S Smart Room Thermostat User Manual
GENERAL ARUNA 300S Smart Room Thermostat User Manual
GENERAL HT250S Digital Room Thermostat User Manual
GENERAL HT250S Digital Room Thermostat User Manual
GENERAL FH260S Underfloor Heating Thermostat User Manual
GENERAL FH260S Underfloor Heating Thermostat User Manual
GENERAL HT100S Digital Room Thermostat User Manual
GENERAL HT100S Digital Room Thermostat User Manual
GENERAL SOLARA 330S SMART Smart Room Thermostat User Manual
GENERAL SOLARA 330S SMART Smart Room Thermostat User Manual
GENERAL HT250 Digital Room Thermostat User Manual
GENERAL HT250 Digital Room Thermostat User Manual
GENERAL SENNA 300 Digital Room Thermostat User Manual
GENERAL SENNA 300 Digital Room Thermostat User Manual
GENERAL ARUNA 300S RF Digital Room Thermostat User Manual
GENERAL ARUNA 300S RF Digital Room Thermostat User Manual
GENERAL SENNA 300 Smart Room Thermostat User Manual
GENERAL SENNA 300 Smart Room Thermostat User Manual
GENERAL MITRA 250S Digital Room Thermostat User Manual
GENERAL MITRA 250S Digital Room Thermostat User Manual

GENERAL FH10, FH10S Underfloor Heating Thermostat User Manual
Get the free PDF manual for the GENERAL FH10, FH10S Underfloor Heating Thermostat User Manual and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

GENERAL FH10, FH10S Underfloor Heating Thermostat User Manual Overview

Summary of Contents

  • Page 1: Place your Room Thermostat in a room you use frequently in your living space. Avoid installing the Room Thermostat in places where there is a lot of air circulation, such as at the doorway or by the window. We recommend that the room thermostat is placed at a height of 150 cm from the floor. FH10/FH10S is a floor heating room thermostat. User provides more comfortable and affordable heating by setting needed room temperature. Your Room Thermostat measures the temperature of the environment it is in every 5 seconds. If the ambient temperature rises 0.5 degrees above the temperature you set, your Room Thermostat turns off the heating unit. If a floor sensor is installed with Room Thermostat, only GENERAL Life floor sensor should be installed. Operations related to the control panel, heating unit or electrical installation must be carried out by persons with professional qualifications. The assembly of product Room Thermostat should be done according to the image above.
  • Page 2: Warranty certificate outlines the terms and conditions for the product. The warranty period starts from the invoice date and lasts for 2 years against manufacturing defects. Devices and apparatus are out of warranty if damaged by the customer or if used with other brands without approval. Battery leakage and errors due to environmental conditions are not covered by the warranty. The repair of devices under warranty is conducted at the company's factory, with transportation costs borne by the customer. Customers can make complaints to consumer courts or arbitration committees. The warranty document must be retained by the customer; a lost document will not be replaced. Malfunctions caused by customer misuse will incur costs to the customer. Customers must report any damages to the manufacturer within the warranty period. Malfunctions due to improper use as stated in the user manual are not covered by the warranty.