GENERAL FH10, FH10S Underfloor Heating Thermostat User Manual
ROOMTHERMOSTATPLACEMENT
WIRINGDIAGRAM FORACTUATOR
ENGLISH
Place your Room Thermostat in a room you use frequently in your
living space. For example; like the hall or living room of your home.
Avoid installing the Room Thermostat in places where there is a lot of
air circulation, such as at the doorway or by the window. Also, do not
place it close to heating units (heater core, fireplace, etc.) and in direct
sunlight. We recommend that the room thermostat is placed at a
height of 150cmfrom thefloor.
N
L
L1
N1
UNDERFLOOR HEATING THERMOSTAT
generallife.com.tr
SERIES:
MITRA, ADEN, ARUNA, CERES, GAIA, ILLONA, NORA, SENNA, TERRA,
THERMA
min. 20 cm
FH10/FH10S USER MANUAL
UNDERFLOOR HEATING THERMOSTAT
GENERALSPECIFICATIONS
FH10/FH10S is a floor heating room thermostat. User provides more
comfortable and affordable heating by setting needed room
temperature.
SensitiveTemperatureMeasurement
Wired Connection
ACTUATOR
SERIES:
ROOMTHERMOSTATWORKINGPRINCIPLE
ON/ OFFControl
MITRA, ADEN, ARUNA, CERES,
GAIA, ILLONA, NORA, SENNA,
TERRA, THERMA
As soon as you energize your Room Thermostat, it will start working.
Your Room Thermostat measures the temperature of the
environment it is in every 5 seconds. If the ambient temperature rises
0.5 degrees above the temperature you set, your Room Thermostat
turns off the heating unit, and if it falls below 0.5 degrees, it turns on
theheating unit.
230V AC
FH10/FH10SANDEQUIPMENTS
Room Thermostat
Dowels and
Screws
WIRINGDIAGRAM FORWIRINGCENTER
FH10/FH10S
USER MANUAL
If the floor sensor measures temperature above 28°C, it turns off the
heating unit. The floor sensor operating sensitivityis ±1°C.*
Thus, it is ensured that the ambient temperature remains within a
certain range.
N
L
L1
N1
*Externalfloor sensor is only activewhen itis connected.
Note: If a floor sensor is installed with Room Thermostat, only
GENERAL Life floor sensor should be installed. Otherwise, the
product willbe out of warranty.
TECHNICALDATA
Dimensions ( H / L / W )
Operating Current
Relay NO Switching Current
85.7mm / 85.7mm / 33.5mm
230V AC
7A (240VAC – Resistive load)
10A (120VAC – Resistive load)
0.1oC
ROOMTHERMOSTATWIRINGDIAGRAM
Temperature Measurement
Accuracy
1
2
3
4
Operating Sensitivity
Operating Temperature Range
Operating Temperature
Storage Temperature
0.5oC
WIRING
CENTER
(5oC) – (30oC)
(-10oC) – (+50oC)
(-20oC) – (+60oC)
230V AC
ROOMTHERMOSTAT
WARNING!
Operations related to the control panel, heating unit or electrical
installation must be carried out by persons with professional
qualifications.
5
Indicator LED
Set Button
N
L
NTC
L1
N1
WARNING!
6
The assembly of product
RoomThermostatIndicatorLEDDescriptions
should be done according to
the image above.
LED light is on
LED light is off
Heating unit is working
Heating unit is not working
For electrical connection,
please see diagram 5.
Should not be used in case
the usage of a wiring center.
generallife.com.tr
1
2
3
| General | Details |
|---|---|
| Name | GENERAL FH10, FH10S Underfloor Heating Thermostat User Manual |
| Make | GENERAL |
| Language | English |
| Filetype | PDF (Download) |
| File size | 1.96 MB |

GENERAL ARUNA 300S Smart Room Thermostat User Manual

GENERAL HT250S Digital Room Thermostat User Manual

GENERAL FH260S Underfloor Heating Thermostat User Manual

GENERAL HT100S Digital Room Thermostat User Manual

GENERAL SOLARA 330S SMART Smart Room Thermostat User Manual

GENERAL HT250 Digital Room Thermostat User Manual

GENERAL SENNA 300 Digital Room Thermostat User Manual

GENERAL ARUNA 300S RF Digital Room Thermostat User Manual

GENERAL SENNA 300 Smart Room Thermostat User Manual

GENERAL MITRA 250S Digital Room Thermostat User Manual

GENERAL FH10, FH10S Underfloor Heating Thermostat User Manual Overview
Summary of Contents
- Page 1: Place your Room Thermostat in a room you use frequently in your living space. Avoid installing the Room Thermostat in places where there is a lot of air circulation, such as at the doorway or by the window. We recommend that the room thermostat is placed at a height of 150 cm from the floor. FH10/FH10S is a floor heating room thermostat. User provides more comfortable and affordable heating by setting needed room temperature. Your Room Thermostat measures the temperature of the environment it is in every 5 seconds. If the ambient temperature rises 0.5 degrees above the temperature you set, your Room Thermostat turns off the heating unit. If a floor sensor is installed with Room Thermostat, only GENERAL Life floor sensor should be installed. Operations related to the control panel, heating unit or electrical installation must be carried out by persons with professional qualifications. The assembly of product Room Thermostat should be done according to the image above.
- Page 2: Warranty certificate outlines the terms and conditions for the product. The warranty period starts from the invoice date and lasts for 2 years against manufacturing defects. Devices and apparatus are out of warranty if damaged by the customer or if used with other brands without approval. Battery leakage and errors due to environmental conditions are not covered by the warranty. The repair of devices under warranty is conducted at the company's factory, with transportation costs borne by the customer. Customers can make complaints to consumer courts or arbitration committees. The warranty document must be retained by the customer; a lost document will not be replaced. Malfunctions caused by customer misuse will incur costs to the customer. Customers must report any damages to the manufacturer within the warranty period. Malfunctions due to improper use as stated in the user manual are not covered by the warranty.