ROOM THERMOSTAT PLACEMENT
WIRING DIAGRAM FOR ACTUATOR
ENGLISH
Place your Room Thermostat in a room you use frequently in your
living space. For example; like the hall or living room of your home.
Avoid installing the Room Thermostat in places where there is a lot of
air circulation, such as at the doorway or by the window. Also, do not
place it close to heating units (heater core, fireplace, etc.) and in direct
sunlight. We recommend that the room thermostat is placed at a
height of 150cmfrom thefloor.
N
L
L1
N1
UNDERFLOOR HEATING THERMOSTAT
generallife.com.tr
SERIES:
MITRA, ARUNA, CERES, GAIA, ILLONA, NORA, SENNA, THERMA
min. 20 cm
FH10/FH10S USER MANUAL
UNDERFLOOR HEATING THERMOSTAT
GENERAL SPECIFICATIONS
FH10/FH10S is a floor heating room thermostat. User provides more
comfortable and affordable heating by setting needed room
temperature.
SensitiveTemperatureMeasurement
Wired Connection
ACTUATOR
SERIES:
MITRA, ARUNA, CERES, GAIA,
ILLONA, NORA, SENNA, THERMA
ROOM THERMOSTAT WORKING PRINCIPLE
ON/ OFFControl
As soon as you energize your Room Thermostat, it will start working.
Your Room Thermostat measures the temperature of the
environment it is in every 5 seconds. If the ambient temperature rises
0.5 degrees above the temperature you set, your Room Thermostat
turns off the heating unit, and if it falls below 0.5 degrees, it turns on
theheating unit.
230V AC
FH10/FH10S AND EQUIPMENTS
Room Thermostat
Dowels and
Screws
WIRING DIAGRAM FOR WIRING CENTER
FH10/FH10S
USER MANUAL
If the floor sensor measures temperature above 28°C, it turns off the
heating unit. The floor sensor operating sensitivityis ±1°C.*
Thus, it is ensured that the ambient temperature remains within a
certain range.
N
L
L1
N1
*Externalfloor sensor is only activewhen itis connected.
Note: If a floor sensor is installed with Room Thermostat, only
GENERAL Life floor sensor should be installed. Otherwise, the
product willbe out of warranty.
TECHNICAL DATA
Dimensions ( H / L / W )
Operating Current
Relay NO Switching Current
85.7mm / 85.7mm / 33.5mm
230V AC
7A (240VAC – Resistive load)
10A (120VAC – Resistive load)
0.1oC
ROOM THERMOSTAT WIRING DIAGRAM
Temperature Measurement
Accuracy
1
2
3
4
Operating Sensitivity
Operating Temperature Range
Operating Temperature
Storage Temperature
0.5oC
WIRING
CENTER
(5oC) – (30oC)
(-10oC) – (+50oC)
(-20oC) – (+60oC)
230V AC
ROOM THERMOSTAT
WARNING!
Operations related to the control panel, heating unit or electrical
installation must be carried out by persons with professional
qualifications.
5
Indicator LED
Set Button
N
L
NTC
L1
N1
WARNING!
6
The assembly of product
RoomThermostatIndicator LED Descriptions
should be done according to
the image above.
LED light is on
LED light is off
Heating unit is working
Heating unit is not working
For electrical connection,
please see diagram 5.
Should not be used in case
the usage of a wiring center.
generallife.com.tr
1
2
3
| General | Details |
|---|---|
| Name | GENERAL LIFE FH10 Underfloor Heating Thermostat User Manual |
| Make | GENERAL LIFE |
| Language | English |
| Filetype | PDF (Download) |
| File size | 1.96 MB |

GENERAL LIFE HT330S RF Room Thermostat User Manual

GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual

GENERAL LIFE HT250 RF Digital Room Thermostat User Manual

GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual

GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual

GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual

GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual

GENERAL LIFE HT220S RF Digital Room Thermostat User Manual

GENERAL LIFE 270S RF Room Thermostat User Manual

GENERAL LIFE 270 Wireless Room Thermostat User Manual

GENERAL LIFE FH10 Underfloor Heating Thermostat User Manual Overview
Summary of Contents
- Page 1: Room thermostat placement Place your room thermostat in a room you use frequently in your living space. Avoid installing the room thermostat in places with a lot of air circulation, such as at the doorway or by the window. Underfloor heating thermostat FH10/FH10S is a floor heating room thermostat. User provides more comfortable and affordable heating by setting needed room temperature. Room thermostat working principle As soon as you energize your room thermostat, it will start working. Your room thermostat measures the temperature of the environment it is in every 5 seconds. If the floor sensor measures temperature above 28°C, it turns off the heating unit. The floor sensor operating sensitivity is ±1°C. If a floor sensor is installed with room thermostat, only General Life floor sensor should be installed. Technical data Dimensions (H/L/W): 85.7mm / 85.7mm / 33.5mm. Operating current: 230V AC. Warning! Operations related to the control panel, heating unit or electrical installation must be carried out by persons with professional qualifications. Room thermostat indicator LED descriptions LED light is on: heating unit is working. LED light is off: heating unit is not working. For electrical connection, please see the diagram. Should not be used in case of the usage of a wiring center.
- Page 2: WARRANTY CERTIFICATE The warranty period starts from the invoice date and is valid against manufacturing defects for 2 years. Devices and apparatus are delivered to the customer in working condition. The repair of the devices and apparatus covered by the warranty is carried out in our company factory. In case of malfunctioning of the devices and apparatus, it is tested in our company to determine the cause. The warranty document must be kept by the customer during the warranty period. Malfunctions resulting from the use of devices contrary to the User Manual are not covered by the warranty. Damages caused by mains voltage or faulty electrical installation are not covered by the warranty. Battery leakage and errors due to rust, oxidation, and liquid contact are not covered by the warranty. Customers can make complaints and appeals to consumer courts or consumer arbitration committees. The customer can request a replacement or repair of the devices at full expense by the manufacturer if manufacturer-induced errors are detected.