Prior to installation/operation of this unit, read installation/operation manual completely. Installation/operation should only be completed by properly trained personnel
Minimum distance to obstructions – 200mm (Exterior) - 100mm (Internal)
NOTICE
DO NOT APPLY external voltage to door contact switch. Damage to unit may result.
Lesen Sie vor der Installation / dem Betrieb dieses Geräts die Installations- / Bedienungsanleitung vollständig durch. Installation / Betrieb sollte nur von entsprechend
geschultem Personal durchgeführt werden
ACHTUNG
NOTICE
Mindestabstand zu Hindernissen - 200 mm (Außen) - 100 mm (Innen)
KEINE externe Spannung an den Türkontaktschalter anlegen. Schäden am Gerät können die Folge sein.
Avant l'installation / l'utilisation de cet appareil, lisez le manuel d'installation / d'utilisation complètement. L'installation / opération ne doit être effectuée que par du
personnel dûment formé
Distance minimale par rapport aux obstacles - 200 mm (supérieur) - 100 mm (interne)
NE PAS APPLIQUER de tension externe au commutateur de contact de porte. Des dommages à l'appareil peuvent en résulter.
Unit Dimensions / Air Flow / Sealing Gaskets
255mm / 10.05“
273mm / 10.74“
Sealing Gaskets
Air In
Air Out
583mm
22.96“
Air Out
Air In
Back View (Evaporator)
Side View
Front View (Condenser)
885505078k
| General | Details |
|---|---|
| Name | Pfannenberg DTS 3041 Thermostat Instructions |
| Make | Pfannenberg |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.1 MB |

Pfannenberg DTS 3041 Thermostat Instructions Overview
Summary of Contents
- Page 1: DTS 3041/3061/3081 - 460V Prior to installation/operation of this unit, read installation/operation manual completely. Installation/operation should only be completed by properly trained personnel. Minimum distance to obstructions – 200mm (Exterior) - 100mm (Internal). Do not apply external voltage to door contact switch. Damage to unit may result. Unit dimensions / air flow / sealing gaskets. Sealing gaskets. Air in. Air out. Back view (evaporator). Front view (condenser).
- Page 2: DTS 3041/3061/3081 - 460V Technical data Cooling capacity at A35°C(95°F)/A35°C(95°F) Cooling capacity at A50°C(122°F)/A40°C(104°F) Refrigerant type: R-134a Refrigerant amount: 400 g (14.1 oz.) Adjustable thermostat setting: 1TAS (factory set) Ambient air temperature range: 0°C - 55°C Air volume for external circulation: 150 m³/h (88 cfm) Power consumption at A35°C(95°F)/A35°C(95°F): 789 W Certifications: CE, CUL US Unit construction: G90 galvanized steel, electrostatically powder coated