Home > GENERAL LIFE > GENERAL LIFE SENNA 300 Wired Room Thermostat User Manual

GENERAL LIFE SENNA 300 Wired Room Thermostat User Manual

ScreenIndicators  
MODE SETTING  
Low Battery Warning: When the “  
” icon appears on the screen, it means  
ENGLISH  
“low battery warning”. It is recommended to replace the batteries when this  
warning appears.  
MODES  
1
8
Warning: When the product is not used for a long period (more than 15 days),  
remove the batteries. Otherwise, malfunctions that may occur would be out of  
warranty.  
2
DIGITAL ROOM THERMOSTAT  
9
10  
WEEKLY  
PROGRAM  
MODE  
PRESET MODES  
MANUAL MODE  
3
4
generallife.com.tr  
Please throwyour dead batteries into thewaste bin forbatteries.  
Economy  
Mode  
Comfort  
Mode  
ROOM THERMOSTAT WIRING DIAGRAM  
5
SENNA 300 USER MANUAL  
Your Room Thermostat has 4 different modes. 3 of them (Comfort and  
Economy Mode) are preset modes. Other modes are manual mode and  
weeklyprogram mode.  
HEATING/COOLING UNIT  
6
7
GENERAL SPECIFICATIONS  
1
2
3
4
5
6
7
8
Hour Indicator  
Day Indicator  
Room Temperature  
Set Temperature  
Economy Mode  
Comfort Mode  
Weekly Program Mode  
Battery Indicator  
Heating Indicator  
In preset modes, temperature values are based on user's choices which  
have been set in the beginning. Manual mode allows the Room Thermostat  
to operate within the temperature which is required and set directly by user.  
Weekly Program mode continues to work according to the weekly schedule  
determined bytheuser.  
SENNA 300 is a wired room thermostat. The user can adjust the room  
temperature with the required temperature and get more comfortable and  
economic heating/cooling.  
Dailyand WeeklyProgramming  
Different Mode Options (Comfort, Economy)  
In order to change the temperaturevaluesof presetmodes:  
NO COM  
Heating Calibration  
ON/OFFControl  
Wired Connection  
Press and hold the “Mode” button for  
Thermostatis on.  
3
seconds while your Room  
Heating/Cooling Option  
TPIAlgorithm  
PreciseTemperatureMeasurement  
9
- If the Heating Indicator is blinking, the heating unit is working.  
- If the Heating Indicator is steady, the heating unit is not working.  
Cooling Indicator  
- If the Cooling Indicator is blinking, the cooling unit is working.  
- If the Cooling Indicator is steady, the cooling unit is not working.  
Comfort Mode temperature value will appear. You may adjust the  
temperaturevalueof Comfort Mode bypressingthe+” and “-” buttons.  
When setting is done, you may adjust the temperature value of Economy  
Mode withthe+” and “-” buttons bypressing the “Modebutton again.  
You mayexitthesetting screen bypressing theModebutton 3 seconds.  
In order to change the manual mode temperature, press the “+” or “-”  
button while in the main screen. The Room Thermostat will switch to  
ManualMode once pressedthe+” or “-” button.  
Warning!  
Operations within the heating / cooling unit or the electrical installation  
must be carriedout byprofessionally qualified persons.  
SENNA 300 AND EQUIPMENTS  
10  
SENNA 300 Room Thermostat  
Alkaline  
Battery  
Dowels and Screws  
ROOM THERMOSTATTEMPERATURE CALIBRATION  
Temperature sensors which are used in Room Thermostats are highly  
sensitive. You mayneed to calibrate yourRoom Thermostat if youwould like  
to get the same temperature values with other thermometers in your living  
space.  
ROOM THERMOSTAT PLACEMENT  
Room Thermostat needs to be placed in the room which is used most  
frequently. For instance; living room or lounge. Placing the Room  
Thermostat in a spot that have air circulation like entrance of a room or side  
of window should be avoided. Also anywhere close to heating/cooling units  
such as radiator, stove and spots which get direct sun lights would not be  
suitable. Room Thermostat needs to be located above the floor 150 cm  
height. Fewtrialsmaybe made to find themost convenientspot.  
You maypresstheModebutton to switchto theother modes.  
While your device is turned off, press and hold the “On/Off“ button for 3  
seconds.  
WEEKLY PROGRAM  
TECHNICAL DATA  
Dimensions  
Operating Current  
Relay NO Switching Current  
You may set the operating schedule of your Room Thermostat with weekly  
program mode. 7 different temperature values can be set for each day in  
weekly programming. These values can be set in temperature adjustment  
screens '' P0-P6''.  
Press the "On/Off" button until the “  
” menu appears. In order to see  
85mm / 125mm / 19mm  
3V DC (2 x AAA alkaline battery)  
2A (30VDC – Resistive load)  
0.5A (125VAC – Resistive load)  
the desired temperature, set the temperature difference by pressing the  
“Temperature Adjustment Buttons”. This value can be arranged between  
“-8° C" and “+8° C".  
Temperature Measurement Accuracy 0.1oC  
Operating Temperature Range  
Battery Life  
Operating Temperature  
Storage Temperature  
In order to set the weekly schedule, press and hold the “Weekly Program“  
button for 3 seconds while your Room Thermostat is on. The “Hour,  
Minute and Day” setting will appear. Press the “Heating & Cooling Option”  
button untilthe“WeeklyProgrammenu (P0)appears.  
In order to save the settings and exit, press the "On/Off" button until the  
deviceturns off.  
(5oC) – (30oC)  
1 Years (2 x AAA)  
(-10oC) – (+50oC)  
(-20oC) – (+60oC)  
Note:Recommended temperaturecalibration is “0.0°C”.  
Days of the week will be blinking on the screen. You can initiate the weekly  
program setting if you wish to set the same schedule for every day of the  
week.  
FACTORY SETTINGS RESET  
You can reset your Room Thermostat to its default factory settings. This  
operation resets the mode temperature values, calibration setting and  
heating/cooling modes to factory setting. In order to reset your Room  
Thermostatto factory setting:  
ROOM THERMOSTAT  
Buttons Functions  
Press the “+” button once if you wish to set the same schedule for the  
weekdays. Firstvedaysof weekwill be blinking on thescreen.  
Press the “+” button once more if you wish to set the same schedule only  
for theweekend. Lasttwodaysof theweekwill be blinking on thescreen.  
Press the “+“ button one more time if you wish to set the same schedule  
for every day of the week. 1st day of the week will be blinking on the  
screen. You can switch between the days by pressing the “+” button.  
Pressthe-” button in order to switchto thepreviousday.  
While your device is turned off, press and hold the “On/Off” button for 3  
seconds.  
1
PresstheOn/Off” button untilthe“  
While in the “ ” menu, select the “  
buttons and presstheOn/Off” button.  
Your devicewill be turned off and resetto factory settings.  
” menu appears.  
” option by using the +” or “-”  
2
3
4
Press theWeeklyProgrambutton once to setaschedule.  
“P0” will be blinking on the screen. Set the temperature value of “P0” by  
pressing the “Weekly Programbutton once more. The hour setting of “P0”  
cannot be changed since it's factory setting.  
BATTERY PLACEMENT  
Before starting, power off the device connected to the Room Thermostat  
and make surethattheenergy is cut off.  
DAY AND HOUR SETTINGS  
While your Room Thermostat is on, keep pressing the “Weekly Program”  
button for 3 seconds.  
5
6
Press the “Weekly Program” button again. Day indicator will be blinking. If  
you will not change the day, press the “Weekly Program” button again and  
switchto the “P1” settingbypressing the+” button.  
At the first screen that appears, hour part will be blinking. You may set the  
timewiththe+” and“-” buttons.  
1
2
3
4
5
6
ON/OFF Button  
Weekly Program Button  
Mode Button  
Heating & Cooling Option  
Temperature Adjustment (Increasing)  
Temperature Adjustment (Decreasing)  
After setting the time, the “Heating & Cooling Optionbutton needs to be  
pressed once. For minute setting, minute part will be blinking. You mayset  
theminute withthe+” and“-” buttons.  
First, hour setting will appear on the screen. Once you complete the hour  
setting, adjust the minute setting by pressing the “Weekly Program”  
button. After the minute setting, press the “Weekly Program” button to set  
thetemperaturevalue.  
After setting the minute, the “Heating & Cooling Optionbutton needs to  
be pressed once to setthe dayof theweek.  
Follow thesamesteps for other schedule settings.  
Mondayhas setastherstdayof theweekand indicated withnumber1".  
Numbers indicate the following days respectively 2-Tuesday,  
3-Wednesday, 4-Thursday, 5-Friday, 6-Saturdayand 7-Sunday  
When setting is done, you may exit by pressing the “Weekly Program”  
button for 3 seconds.  
Once all changes made, press and hold the “Weekly Program” button for 3  
seconds to save.  
Note: In order to check the weekly schedule which has been set without  
making any changes, press the “Weekly Program” button once while your  
Room Thermostat is on. Press the “+” and “-” buttons to see the days, press  
theModebutton to seethesettings betweenP0-P6”.  
As shown in the picture above, press the screwdriverforward from the space  
shown, bend the tabs and separate the front cover. Insert 2 new AAA alkaline  
batteries in the battery housing with the correct battery direction. Replace  
both batteries at the same time. Then align the front part of your Room  
Thermostatto thebackand squeezeittowards theback.  
1
2
3
4
GeneralDetails
NameGENERAL LIFE SENNA 300 Wired Room Thermostat User Manual
MakeGENERAL LIFE
LanguageEnglish
FiletypePDF (Download)
File size2.07 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
GENERAL LIFE HT330S RF Room Thermostat User Manual
GENERAL LIFE HT330S RF Room Thermostat User Manual
GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual
GENERAL LIFE HT250 RF Digital Room Thermostat User Manual
GENERAL LIFE HT250 RF Digital Room Thermostat User Manual
GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual
GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual
GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual
GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual
GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual
GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual
GENERAL LIFE HT220S RF Digital Room Thermostat User Manual
GENERAL LIFE HT220S RF Digital Room Thermostat User Manual
GENERAL LIFE 270S RF Room Thermostat User Manual
GENERAL LIFE 270S RF Room Thermostat User Manual
GENERAL LIFE 270 Wireless Room Thermostat User Manual
GENERAL LIFE 270 Wireless Room Thermostat User Manual

GENERAL LIFE SENNA 300 Wired Room Thermostat User Manual
Get the free PDF manual for the GENERAL LIFE SENNA 300 Wired Room Thermostat User Manual and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

GENERAL LIFE SENNA 300 Wired Room Thermostat User Manual Overview

Summary of Contents

  • Page 1: Low battery warning: When the icon appears on the screen, it means low battery warning. It is recommended to replace the batteries when this warning appears. Warning: When the product is not used for a long period (more than 15 days), remove the batteries. Otherwise, malfunctions that may occur would be out of warranty. Your room thermostat has 4 different modes. 3 of them (Comfort and Economy Mode) are preset modes. Other modes are manual mode and weekly program mode. In preset modes, temperature values are based on user's choices which have been set in the beginning. Manual mode allows the room thermostat to operate within the temperature which is required and set directly by user. Weekly program mode continues to work according to the weekly schedule determined by the user. Room thermostat needs to be placed in the room which is used most frequently. Avoid placing it in spots with air circulation or near heating/cooling units. You may set the operating schedule of your room thermostat with weekly program mode. 7 different temperature values can be set for each day in weekly programming. You can reset your room thermostat to its default factory settings. This operation resets the mode temperature values, calibration setting, and heating/cooling modes to factory setting. Before starting, power off the device connected to the room thermostat and ensure that the energy is cut off. Insert 2 new AAA alkaline batteries in the battery housing with the correct battery direction. Replace both batteries at the same time.
  • Page 2: TPI room thermostat working logic Your room thermostat works with the TPI algorithm, predicting temperature changes to maintain your desired temperature with minimal deviation. If the placement of the TPI room thermostats is changed, the learning process will restart and should be considered as 7 days. Devices and apparatus are delivered in working condition, with on-site commissioning subject to a service fee. The repair of devices covered by the warranty is carried out in our company factory, and transportation costs are the customer's responsibility. The maintenance of devices is done in our company, and round travel fares belong to the customer. TPI technology ensures energy efficiency by measuring and applying optimal timings for maintaining the set temperature. In non-TPI thermostats, the heating/cooling unit operates continuously, causing greater temperature fluctuations compared to TPI thermostats. Malfunctions caused by customer misuse are not covered by the warranty. The warranty period starts from the invoice date and covers manufacturing defects for 5 years. The warranty document must be kept by the customer during the warranty period; if lost, repairs will incur a fee.